background image

Page 10 / 80

GQ, GX, GM Rev. 5 - Operating Instructions

GB

1.4 Warranty

For  the  product  warranty  refer  to  the  general  terms

and conditions of sale. 

The warranty covers only the replacement and

the  repair  of  the  defective  parts  of  the  goods

(recognized by the manufacturer).

The  Warranty  will  not  be  considered  in  the  following

cases:

- Whenever  the  use  of  the  device  does  not  conform

to the instructions and information described in this

manual.

- In  case  of  changes  or  variations  made  without

authorization of the manufacturer.

- In  case  of  technical  interventions  executed  by  a

non-authorized personnel.

- In case of failing to carry out adequate maintenance.

1.5 Technical assistance

Any  further  information  about  the  documentation,

technical assistance and spare parts, shall be reque-

sted from: Calpeda S.p.A. (paragraph 1.2).

2 TECHNICAL DESCRIPTION

See  designation  on  the  pump  name-plate  or  on  the

bar-code label.

Meaning of the designations:

GX 

= Stainless steel pump.

GM 

= Cast iron pump.

GQ

= Cast iron and Stainless steel pump.

R

= With open impeller

C,N

= With two-  (

GXC

) or  single-passage

(

GMC

) impeller.

V,S

= With free-flow (vortex) impeller.

G

= Impeller with high power grinder.

M

= With  single-phase  motor  (without

indication = with three-phase motor).

2.1 Intended use

Standard construction

-  For  clean  or  slightly  dirty  water,  with  solids  in

suspension up to 10 mm grain size. for 

GQR

.

- For  clean  and  dirty  water,  also  containing  solids

with maximum size: 

35 mm for 

GXC, GXV

;

45 mm for 

GMC

50 mm for

GQN, GQS, GQV, GMV.

With  a  high  solid  content  or  with  filamentous  par

ticles  use  only  the  free-flow  (vortex) 

GXV,  GQS,

GQV

GMV

or 

impeller  with  high  power  grinder

GQG 

construction.

- Maximum liquid temperature: 35 °C.

- Maximum liquid density: 1100 kg/m

3

.

- Minimum

dimensions 

of 

installation 

pit:

0.55x0.55m; depth 0.5 m.

- Minimum immersion depth see also sections 6.5., 6.6.

- Maximum submersion depth 5 m, 10 m for 

GMC,

GMV 

(with suitable cable length).

For outdoor use the power supply cable must have

a length of not less than 10 m.

2.2 Improper use

The device is designed and built only for the purpose

described in paragraph 2.1.

Do  not  use  in  garden  ponds,  tanks  or

swimming  pools  when  people  are  in  the

water.

The Pump cannot be used in explosive or

flammable environments.

Improper use of the device is forbidden, as is

use  under  conditions  other  than  those

indicated in these instructions.

Improper use of the product reduces the safety and the
efficiency of the device, Calpeda shall not be responsi-
ble for failure or accident due to improper use.

2.3 Marking

The following picture is a copy of the name-plate that
is on the external case of the pump.

3 TECHNICAL FEATURES
3.1 Technical data

Dimensions and weight (paragraph 12.1).
Nominal speed 2900/3450 rpm
Protection IP X8
Supply voltage / Frequency:

- up to 240V 1~ 50/60 Hz

- up to 480V 3~ 50/60 Hz

Check  that  the  mains  frequency    and  voltage  corre-

spond  to  the  electrical  characteristics  shown  on  the

indicator plate.
Sound  pressure  at  minimum  immersion  depth:  <  70
dB (A), < 75 dB (A) for GQG.
Noise  disappears  or  decreases when  the  pump  is
submersed.
Maximum starts/hour: 30 at regular intervals.
Maximum  permissible  working  pressure  up  to  60  m
(6 bar).
Maximum suction pressure: PN (Pa) - Hmax (Pa).

4 SAFETY
4.1 General provisions

Before  using  the  product  it  is  necessary  to
know  all the safety indications.

Carefully  read  all  operating  instructions  and
the indications defined for the different steps:
from transportation to disposal.
The  specialized  technicians  must  carefully
comply with all applicable standards and laws,
including  local  regulations  of  the  country
where the pump is sold.
The  device  has  been  built  in  conformity  with
the  current  safety  laws.  The  improper  use
could damage people, animals and objects.
The  manufacturer  declines  any  liability  in  the
event of damage due to improper use or use
under conditions other than those indicated on
the name-plate and in these instructions.

Follow  the  routine  maintenance  schedules
and the promptly replace damaged parts, this
will  allows  the  device  to  work  in  the  best
conditions.

i

i

Made in Italy

XXXXXXX

Q min/max 

X/X

 m

3

/h

XXXXXXX

H max/min 

X/X

 m

IP 

XX

XXXX

/min

220∆/380Y V3~50Hz

cosø 

X

X/X

 A

XXXXXXXX

S1   l.cl. 

X

   

X

 kg

X

 kW   (

X

Hp)    S.F.

1

2

3

4

5

6

7

8

9 10

16
15

14

13

12

11

Montorso (VI) Italy  IT 00142630243

1 Pump type
2 Delivery
3 Head
4 Rated power
5 Tension nominale
6 Nom. motor current
7 Notes
8 Fréquence

9 Operation Duty
10 Insulation class
11 Weight
12 Power factor
13 Rotation speed rpm
14 Protection
15 Serial number
16 Certifications

IST GQ_GX_GM_07_2018R5_MXS 11_03con gall  09/07/18  09:06  Pagina 10

Summary of Contents for GQ

Page 1: ...aliano ORIGINAL OPERATING INSTRUCTIONS Page 9 English ORIGINAL BETRIEBSANLEITUNG Seite 16 Deutsch INSTRUCTIONS ORIGINALES POUR L UTILISATION Page 23 Fran ais INSTRUCCIONES ORIGINALES DE USO P gina 30...

Page 2: ...The maximum permissible structural working pressure Chapter 3 1 The type and section of the power cable Chapter 6 8 The type of electrical protection to be installed Chapter 6 8 1 1 Symbols To improve...

Page 3: ...d in explosive or flammable environments Improper use of the device is forbidden as is use under conditions other than those indicated in these instructions Improper use of the product reduces the saf...

Page 4: ...on and in order to fulfill the device requirements electrical supply etc It s Absolutely forbidden to install the machine in an environment with potentially explosive atmosphere 6 3 Unpacking Inspect...

Page 5: ...garden ponds and similar places a residual current device with I N not exceeding 30 mA must be installed in the supply circuit Install a device for disconnection from the mains switch with a contact...

Page 6: ...rician or to an expert techni cian Every maintenance operations cleaning or reparation executed with the electrical system under voltage it could cause serious injuries to people A possible replacemen...

Page 7: ...armaceutic use For the GMC GMV pumps a normal engine oil of the SAE 10W 30 type can also be used 9 DISPOSAL European Directive 2012 19 EU WEEE The final disposal of the device must be done by spe cial...

Page 8: ...erload protection is set correctly see data on the engine indicator plate and make sure that the fuseboard upline of the engine has been properly connected 1c Check the power supply and make sure that...

Page 9: ...11 70 12 71 12 1 71 12 2 75 12 3 76 79 1 CALPEDA S P A 2 3 CE 8 3 1 6 8 6 8 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 1 5 Calpeda S p...

Page 10: ...EDA 2 3 3 3 1 12 1 2900 3450rpm IPX8 240V 1 50 60 Hz 480V 3 50 60 Hz 70 dB A 75 dB A GQG 30 60 m 6 bar PN Pa Hmax Pa 4 4 1 CALPEDA S P A 4 2 4 3 4 4 4 5 5 12 1 i Made in Italy MONTORSO XXXXXXX Q min m...

Page 11: ...h min mm mm GQR GQS GQV GQS GQV GQS GQV GQS GQV GQS GQV mm h min h max 225 240 240 265 285 315 330 330 355 375 h max h min min 300 x 250 3 93 037 3 GQRM 10 10 GF GQRM 10 12 GF GQRM 10 14 GF GQRM 10 16...

Page 12: ...RN8 F 12 2 6 8 2 GQG H07 RN8 F 6 8 3 GQR GQN GQS GQV GXC GXV GQG D 6 8 4 GMC GMV D 12 2 7 7 1 7 2 GQG 35 GQR GQN GQS GQG GQV 7 3 6 5 8 CALPEDA CALPEDA S P A 8 1 ON OFF OFF i i OFF IST GQ_GX_GM_07_2018...

Page 13: ...33 12 50 12 52 12 60 14 00 14 14 O 14 15 14 20 14 22 14 24 14 46 14 47 14 80 15 50 15 70 28 00 28 04 28 08 28 20 34 03 34 04 34 05 34 08 34 09 34 12 34 13 36 00 40 00 64 08 64 12 O 70 00 70 05 O 70 08...

Page 14: ...2 3 4 5 6 1a 1b 1c 1d 1e 1f 2a 2b 3a 3b 4a 4b 4c 4d 4e 4f 5a 5b 5c 5d 5e 6a 6b 1a 1b 1c 1d a c 1e 2 1f 2a 2b 3a 3b 2b 4a 4b 4c 4d 4e 4f 5a 5b 5c 5d 5e 6a 6b 6a 6b IST GQ_GX_GM_07_2018R5_MXS 11_03con...

Page 15: ...0 220 245 265 265 295 h min GQR M 10 16 GQR M 10 18 GQR 10 20 GQRM 10 20 kg GQRM 15 15 5 15 5 18 19 20 5 fM GQR GQR M 10 32 10 395 410 410 435 455 455 485 14 7 15 2 15 2 16 7 18 3 19 7 GQR M 10 32 12...

Page 16: ...0 G1 1 2 ISO 228 fM mm mm kg GXV 10 1 11 7 11 7 11 7 13 2 13 2 GXV M 40 7 433 GXV M 40 8 458 508 533 248 273 458 GXV M 40 9 533 273 GXVM kg GXC 10 1 11 7 11 7 13 2 GXC M 40 10 433 GXC M 40 13 458 508...

Page 17: ...543 568 588 588 618 308 328 328 358 On Off kg h min h max 50 DN 50 90 fM 89 94 242 430 452 G 2 ISO 228 GQV 15 15 2 16 19 20 5 16 16 2 18 20 5 22 GQV M 50 8 GQV M 50 9 460 535 535 275 275 485 GQV M 50...

Page 18: ...2 2 PN 10 2 GMC 50CE GMC 50BE GMC 50AE GMCM 50CE GMCM 50BE 28 29 30 5 28 29 5 kg GMV 50CE GMV 50BE GMV 50AE GMVM 50CE GMVM 50BE 27 28 29 5 27 28 5 kg GMC 50 65C GMC 50 65B GMC 50 65A GMCM 50 65C GMCM...

Page 19: ...ator coil Zum Schutzrelais f r Thermo Schutzschalter Protecteurs thermiques vers la bobine du contacteur Termoprotectores a conectar a la bobina del contactor 4 67 380 nero black schwarz noir negro sv...

Page 20: ...96 09 76 64 76 02 96 12 76 60 96 02 36 00 70 23 28 20 94 00 82 30 82 05 70 20 82 04 28 04 GQV 50 GQR GQR 10 GQR 10 32 14 80 14 00 28 04 GQN 50 GQS 50 14 80 14 00 12 3 Disegno per lo smontaggio ed il r...

Page 21: ...76 64 76 02 96 12 76 60 96 02 36 00 70 23 28 20 94 00 82 30 82 05 70 20 82 04 GXC GXV 28 04 14 00 12 00 12 21 12 3 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeic...

Page 22: ...20 76 64 82 04 81 00 78 00 76 00 94 12 94 04 94 00 14 24 14 00 28 00 28 04 12 00 96 09 12 3 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Demontage und...

Page 23: ...ektiv 2006 42 EC 2014 30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder D F E DK CALPEDA S p A intygar att pumpar GX GX M GQ GQ M GM GM M pumptyp och serienummer visade p nam...

Page 24: ...tification de la pompe submerg e enlever l tiquette avec le code barre du carton d emballage et l appliquer ici Para facilitar la identificaci n de la bomba sumergida cortar la etiqueta con el c digo...

Reviews: