Page 24

Model  

QUASAR 2

Serial Number
Draw off Capacity 

 9 Litres  

Heat-up Time 

(first switch-on)  

                   

9 Litre capacity                   

45 Minutes

Average flow rate from 
dispense valve

 2.8 Litres / Minute  

Voltage

220 - 240 V ac   50-60 Hz

Power rating

 3kW (MAX)

PLEASE ENTER  SERIAL NUMBER FOR FUTURE 
REFERENCE

Note:  All measurements are approximate.

 

PLEASE CONTACT OUR SERVICE DEPARTMENT FOR ASSISTANCE

 

Calomax Limited, Lupton Avenue, Leeds LS9 7DD

 

Tel: 0113 249 6681

 

Fax: 0113 235 0358

 

e-mail: [email protected]

Summary of Contents for QUASAR 2

Page 1: ...ND SERVICING INSTRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully before...

Page 2: ...TROUBLE SHOOTING 19 MAINTENANCE AND SERVICE HISTORY 20 22 WARRANTY 23 PRODUCT SPECIFICATION 24 CHECK LIST Before commencing installation check that the following parts have been supplied with the boi...

Page 3: ...ve must be fitted to the supply BEFORE CONNECTING THE SUPPLY PIPE MUST BE THOROUGHLY FLUSHED OUT TO ENSURE THAT FOREIGN MATTER DOES NOT BLOCK OR ENTER THE SOLENOID VALVE The boiler must be connected t...

Page 4: ...luminated On subsequent operation of the boiler The boiler will fill and heat in cycles It will allow only a limited amount of water to enter the unit at any one time and then switch off the solenoid...

Page 5: ...suitably qualified engineer GENERAL NOTES GENERAL OPERATION Avoid using any abrasive materials Wiping the outer casing with a damp cloth should be sufficient Some stainless steel cleaning products may...

Page 6: ...not rectify the problem turn off the water supply and remove the flexible hose to check for debris in the valve s filter The unit can be used normally while the service indicator is flashing a 4x puls...

Page 7: ...equired are not identified please contact Calomax Limited Includes nuts washers etc Exploded parts view for Quasar 2 boiler To be read in conjunction with the spare parts list Body cut away to show in...

Page 8: ...tight joint Damage to the unit caused by a poor lid seal is not covered by warranty Scale deposits should be removed from all internal surfaces particularly the heating element thermistor and level s...

Page 9: ...DPBK NB15BLG CASSV CAP330 NBE3HK FIH CASMR CASLPK NBPRG MULLER DISPENSE VALVE GROMMET DISPENSE VALVE SERVICE KIT MAIN PRINTED CIRCUIT BOARD Inc TRIAC WATER DISPENSE PUSH BUTTON Inc FITTING TOOL AUXIL...

Page 10: ...place as required Lower operating temperature Replace element Replace Circuit Board Triac sold as a matched pair Overflows Dirt in solenoid valve Level sensors require de scaling or replacing Main Pri...

Page 11: ...Page 20 Page 21 MAINTENANCE AND SERVICE HISTORY MAINTENANCE AND SERVICE HISTORY...

Page 12: ...s are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Limescale build up The last i...

Page 13: ...ate from dispense valve 2 8 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 3kW MAX PLEASE ENTER SERIAL NUMBER FOR FUTURE REFERENCE Note All measurements are approximate PLEASECONTACTOURSERVI...

Reviews: