Install the fiber
To install the fiber, you will need to install and route the cabling, splice and terminate the
fiber, then seal and support the fiber cables within the splice compartment.
Procedure to install the fiber cabling
Example of fiber cable routing
Step
Action
1.
Route the fiber cable up through a cable entry hole in the bottom of the side
splice compartment. Leave 8-10 feet of cable hanging out of the cabinet.
2.
Slide a 2" fiber cable entry plate down the fiber cable and fasten the plate to
the bottom of the side splice compartment.
3.
Slide a 2" cold shrink tube down the subscriber cable with the loose pull tab
of the cold shrink removable core feeding from the bottom of the tube
through to the top.
The fiber cable is routed up the left side of the compartment
and supported by the fiber strain relief bracket.
Pigtails are spliced to the fiber with the splices placed in the
fiber splice trays.
Summary of Contents for ODC-10
Page 1: ...Calix ODC 80 Installation Guide July 2003 Part 220 00029 Rev 11...
Page 2: ......
Page 6: ......
Page 7: ...1 Chapter Before You Begin Installing the ODC 80...
Page 8: ......
Page 23: ...2 Chapter Placing the ODC 80 on a Pad...
Page 24: ......
Page 30: ......
Page 31: ...3 Chapter Installing Power Subscriber Cables and Equipment...
Page 32: ......
Page 74: ......
Page 75: ...4 Chapter Maintaining and Troubleshooting the ODC 80...
Page 76: ......
Page 80: ......
Page 92: ......
Page 103: ...5 Chapter Reference...
Page 104: ......
Page 106: ......