Installation Prerequisites
Site requirements
You will need a concrete pad with conduit entry for subscriber cables, AC power, and
ground to support the Calix ODC-80.
Install a ground rod, or similar grounding device, with a maximum resistance to ground of
20 ohms near the pad site.
See the "Calix ODC-80 Pour-In-Place Template Instructions" if you plan to construct the
pad using a Calix template.
Footprint dimensions
Recommended pad dimensions are 148 inches by 96 inches; 5 1/2 inches deep. Pad depth
may vary depending on site and environmental conditions.
These pad dimensions allow for full door clearance around the cabinet.
Footprint clearance