Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved..
2.3.1.6 STATUS LED LED
2.3.2 LEDs on Connectors
2.3.2.1 LAN RJ-45 Connector LEDs
2.3.2.2 DS1 RJ-48c Connector LEDs
2.4 2364 ONT Reset Button
The reset button may be pushed in with a straightened paperclip or similar device.
Green
Initialization is compete, power-on diagnostic passed.
Blinking
Initializing, running power-on diagnostic. This may also indicate that a software upgrade is in prog-
ress to alert the user not to reset or power cycle the ONT.
Off
Power-on diagnostic failed.
Green
Link is up and active
Off
The link is not active.
Red
The link is in red alarm mode. (LOS)
Red Blinking
The link is in blue alarm mode. (AIS)
Green
No alarm is present.
Time Held
Action
Hold for 0-2 seconds
The ONT performs a hard reset.
Hold for 2-6 seconds
The ONT performs a soft reboot.