4.1.3 Status Indicator Lights
Eight yellow LED status indicato
panel. These LED’s correspond
Hi Range
output range
Overtemp
e
t
rol
indicator will be lit
whenever the ATN line (Attention) line is asserted by the IEEE
controller. If the RS232C, USB or LAN interface is used, the
REMOTE state can be enabled by the controller using the
nt
he BACK button
in
s of
settings in ATE applications.
Output on/off
The
Output on/off
LED indicates the output relay status. If the
LED is off, the output relays for all output phases are open and
the external sense lines are wrapped around internally. If the
LED is on, the output relays are closed and the external sense
lines are connected to the SENSE terminal block.
ØA, ØB, ØC
The
ØA, ØB, ØC
LED indicates the output phase selection for
either settings or measurements. Phase selection can be
changed using the
Phase
button to the right of the MEMU keys.
Pressing the
Phase
button repeatedly will cycle through phase
A, B, C and ALL PHASES. The
ØA, ØB, ØC
indicators
correspond to outputs ØA, ØB, ØC on the rear panel.
If all three phase selection LED's are lit, all three phases are
selected and changes made to voltage and current limit settings
will apply to all three phases.
Note that in single-phase mode, the ØA LED is always lit and
the Phase button is inactive.
rs are located on the left hand side of the keyboard/display
to the following conditions:
The
Hi Range
LED is on when the high voltage
has been selected.
The
Overtemp
LED indicates an overheating problem insid
the unit. This is an abnormal condition, which will cause the uni
to shut off. Check the air openings to make sure they are not
blocked.
Overcurrent
The
Overcurrent
LED indicates an output overload condition.
This condition can be controlled by setting the current limit
value in the PROGRAM menu. Removing the load using the
OUTPUT ON/OFF button will recover from an overload
condition when in CV mode.
Remote
The
Remote
LED indicates that the unit is in remote cont
mode. If the IEEE-488 interface is used, this
SYST:REM command. Any time the
Remote
LED is lit, the fro
panel of the power source is disabled. Note: T
doubles as a GOTO LOCAL button (LOCAL) while the unit is
remote state. This allows the user to regain control of the front
panel. The LOCAL button can be disabled by sending a Local
Lockout bus command. This prevents unauthorized change
California Instruments
49
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...