User and Programming Manual - Rev N
3.3.1 Low Input Voltage Range Configuration (103 – 127 V)
In order to change the voltage range configuration:
1.
Turn off the input circuit breaker.
2.
Disconnect AC input power to the source by unplugging the power cord.
3.
Remove the AC Power Source top cover by removing (14) #6-32 x 5/16” FLH
screws. There are 7 screws on the sides and 7 screws on the top that hold the
cover.
Remove the (2) #6-32 x 1” PHN screws and lock washers that hold the amplifier
near the outside panel.
4
Remove the (2) #6-32 x 3/8” PHN screws and lock washers located near the
connector, attaching the red insulator to the center bracket.
6.
Remove the amplifier by pulling it away from the connectors and then lifting it up and
out of the amplifier cage.
5
Locate and remove the (2) #8-32 x 1/2” FLH screws on the outside of the chassis
which attaches the perforated support bracket to the chassis, and lift perforated
support bracket up and out of unit.
The low input voltage range is set by making the following connections inside the
power source:
Remove wire #5 (white, 10AWG) going to CR1-AC and re-connect to A6-E2 on the
DC supply board.
Jumper
A6-W3
Remove
Jumper
A6-W2
Install
Jumper A6-W1
Install, use jumper in spare holder W4.
7
2001RP April
2007
15
Summary of Contents for 2001RP
Page 33: ...User and Programming Manual Rev N Figure 3 7 Test Setup 2001RP 24 April 2007 2001RP...
Page 47: ......
Page 60: ...User and Programming Manual Rev N Figure 6 3 Internal Adjustments 2001RP April 2007 51...
Page 65: ...User and Programming Manual Rev N Figure 7 1 Assembly Location 56 April 2007 2001RP...
Page 68: ...User and Programming Manual Rev N Figure 7 2 Replaceable Fuse Locations 2001RP April 2007 59...
Page 70: ...User and Programming Manual Rev N Figure 8 1 Rear Panel View 2001RP April 2007 61...
Page 90: ......