1 = Under Volt Test
2 = Over Volt Test
3 = Return
If Key 1 is selected "Volt/Freq Menu" from the Emergency Menu, the following Menu will appear:
1 = Emg Vunder Test
2 = Emg Vover Test
3 = Return
If Key 1 is selected "Volt Menu" from the Abnormal Menu, the following Menu will appear:
1 = Ab Vunder Test
2 = Ab Vover Test
3 = Return
If Key 3 or Key 7 is selected from the "Normal Menu", another screen will appear as follows:
Enter Modulation
Rate in Hz and ENT.
The numeric value must be within the limits for the test performed. See Figure 2 and Figure 3.
If Key 4 is selected from the "Normal Menu", the following screen will appear as follows:
Enter Test
Number 1 to 15 and ENT (see Table 1)
10.5 GPIB
OPERATION
The following command will be used to execute the appropriate section of DO-160C.
Remote
Command
DO160[A][B][C] :NORMal state :VOLT_FREQ :MINinum
DO160[A][B][C] :NORMal state :VOLT_FREQ :MAXimum
DO160[A][B][C] :NORMal state :VOLTage :UNBalance
D0160[A][B][C] :NORMal state :WAVe form :DISTortion
DO160[A][B][C] :NORMal state :VOLTage :MODulation <numeric>
DO160[A][B][C] :NORMal state :FREQency :MODulation <numeric>
DO160[A][B][C] :NORMal state :VOLTage :UNDer<numeric>
DO160[A][B][C] :NORMAL state :VOLTage :OVER
DO160[A][B][C] :EMERgency :VOLT_FREQ :MINimum
DO160[A][B][C] :EMERgency :VOLT_FREQ :MAXimum
DO160[A][B][C] :EMERgency :VOLTage :UNBalance
DO160[A][B][C] :ABNormal stage :VOLTage :MINimum
DO160[A][B][C] :ABNormal state :VOLTage :MAXimum
DO160[A][B][C] :ABNormal stage :VOLTage :UNDer
DO160[A][B][C] :ABNormal state :VOLTage :OVER