CALIENT S Series Quick Start Manual Download Page 1

 

 

 

 
 
 

CALIENT Optical Circuit Switch (OCS)  

WebGUI Quick Start Guide 

 

 

Summary of Contents for S Series

Page 1: ...CALIENT Optical Circuit Switch OCS WebGUI Quick Start Guide...

Page 2: ...ogy that is protected under one or more pending or issued United States and foreign patents This manual may not be copied wholly or in part without prior written permission from CALIENT Technologies T...

Page 3: ...28 2015 Rev 0 2 Page 3 of 63 Revision History Date Version Description Author s 04 08 2013 Legacy documentation T Douglas 07 13 2015 0 1 Update with latest WebGUI info implement new user doc formattin...

Page 4: ...uration 17 4 1 2 Node Summary Node Config Backup Restore 18 4 1 3 Node Summary Node Config SNMP Configuration 20 4 1 3 1 SNMP v1 v2c Get Set Parameters 20 4 1 3 2 SNMP Trap v1 v2c Parameters 20 4 1 3...

Page 5: ...ross Connect Details 42 6 2 Cross Connects Summary 45 6 2 1 Cross Connects Summary Cross Connection Details 47 6 3 Cross Connects Save Recall 49 7 PORTS 51 7 1 Ports Summary 51 7 1 1 Ports Summary Por...

Page 6: ...Active Alarm Summary All Alarms Events 11 Figure 3 Configuring SNMP v1 v2c Get Set Parameters 20 Figure 4 Configuring SNMP v3 Get Set Parameters 23 Figure 5 Configuring SNMP v3 Trap Parameters 24 Lis...

Page 7: ...on how to manage CALIENT s S320 and S160 switches over the Web using a graphical user interface GUI AUDIENCE This guide is written for the network operations center and field service personnel who co...

Page 8: ...ffective user friendly tool for managing one or multiple switches across the Web The WebGUI enables system administrators to easily monitor and manage a variety system components and functionality inc...

Page 9: ...escribes how to access the WebGUI 1 Type the IP address of the OCS in your Web browser 2 Press Enter on your keyboard to launch the WebGUI The Login page will appear 3 Type the default user name admin...

Page 10: ...y on the switch Access to detailed operational data and assorted administrative tools is provided via buttons in the upper right corner of the page and a navigation menu at the left of the page 3 1 Ho...

Page 11: ...lecting from the different options displayed in the dropdown menus for the Type Severity and Class fields Click the down arrow at the right of each field to display the filtering options for the field...

Page 12: ...options include ALL lists all classes of alarms events COM lists Component System alarms events CRS lists Connection related alarms events ENV lists System Environment e g hardware CPU alarms events E...

Page 13: ...nge Password button The Change Password screen will display 2 Type the old password in the Old Password field of the screen 3 Type the new password in the New Password field of the screen 4 Re type th...

Page 14: ...f free ports before connections are made is 324 320 4 spare ports For the S160 OCS the total number of free ports before connections are made is 162 160 2 spare ports 4 1 Node Summary Node Config The...

Page 15: ...Guide Doc Part No 460185 00 July 28 2015 Rev 0 2 Page 15 of 63 4 1 1 1 General and Service Configuration This section of the Node Configuration screen lets the user configure the name of the node and...

Page 16: ...and back into the WebGUI Once this has been done the new name will appear in the upper left corner beneath the CALIENT logo on every page of the WebGUI DB Status is a non configurable descriptive fiel...

Page 17: ...and are not configurable 4 1 1 3 Time Security and Dynamic Update Configuration Of the Time Configuration settings the Current Date Time can be set by clicking the calendar icon at the right of the f...

Page 18: ...re after the specified number of days Similarly the Usage Inactivity field specifies whether or not to disable a user based on the individual s site usage Values for the setting include 0 zero the use...

Page 19: ...atabase including port thresholds ALIAS PORTGROUPS and Connection Information 4 To restore the system do the following a Under Restore Location click the Local File System radio button or the Remote F...

Page 20: ...the community name to the specified IP Address only By default one public read only community and one private read write community are created and added to the configuration Authorized users can add d...

Page 21: ...rap v2 Trap or v2c Inform Yes Retry The number of times the agent will resend the Inform message if an acknowledgement is not received Yes if the trap type is v2c Inform Timeout The timeout in seconds...

Page 22: ...ameters as they appear in the WebGUI If a user is being utilized in a Trap v3 configuration the user cannot be modified or deleted unless that specific Trap v3 configuration entry exists Table 3 SNMP...

Page 23: ...acy values can be Yes or No Yes Priv Password Privacy Password Yes if the Security Level is authPriv and Same Password for Auth Priv is No The SNMP v3 Engine ID and user parameters are displayed in th...

Page 24: ...e trap should be sent Yes Trap Port The port number to which the trap should be sent No the default value is 162 Trap Type The type of trap to be sent the value can be v3Trap or v3Inform Yes Retry The...

Page 25: ...onfiguration screen will open 4 Type in the desired values for the following fields Max_Backoff specifies the maximum number of retries for connecting to the Controller Probe Interval specifies the el...

Page 26: ...rms using the WebGUI 1 Log into the WebGUI 2 Navigate the following path Node Summary Alarm Config The Alarm Configuration screen will open 3 Type a value in the Soak Interval field to specify the len...

Page 27: ...e button at the bottom of the screen to save any changes or click the Reset button to disregard them 4 3 Node Summary Software Management The following steps describe how to monitor the software versi...

Page 28: ...de Summary 3 Click the System Mgmt tab on the Node Summary screen The System Management screen will open displaying the following command options Reboot reboots only the current CP if redundancy is en...

Page 29: ...of the command options to select that command 5 Click the Apply button at the bottom of the screen to implement the specified command 4 5 Node Summary Session Management The following procedure descr...

Page 30: ...duration of the timeout for the selected session Acceptable values are 0 the session never times out or 10 to 60 minutes the session ends when the specified time is reached b Click the Save button to...

Page 31: ...en to end the session for the selected user s 4 6 Node Summary User Management The following procedure describes how to access the system s User Management tools via the WebGUI 1 Log into the WebGUI 2...

Page 32: ...e field to display a dropdown menu The following options will appear Provisioner Administrator Field Install Maintenance Read Only For a detailed description of each user role refer to the User Access...

Page 33: ...the bottom of the screen to create a new user based on the information specified in steps 3 through 6 OR click the Reset button to clear all the specified information and start over OR click the Back...

Page 34: ...If the check box is not selected the Password field will not accept input 5 Click the Save button at the bottom of the screen to save the changes specified in step 4 OR click the Reset button to clear...

Page 35: ...o select that user The User Detail for the selected user will appear beneath the list of users 3 Click the Enable User button at the bottom of the screen to enable the selected user on the system OR c...

Page 36: ...provides detailed information for each board installed in the system including the board type its location slot and its alarm state The following steps describe how to access the Board Details screen...

Page 37: ...ts all the ports mirrors on the system and the corresponding hardware component s driving controlling each mirror Each port is mapped to a mirror which is controlled by a cell within an LH RH board Th...

Page 38: ...the mirrors and corresponding hardware components driving controlling each mirror Each mirror is controlled by a cell within an LH RH board and power information for that mirror is available on the ti...

Page 39: ...llowing procedure describes how to add a cross connection to the switch 1 Log into the system 2 Navigate the following path Cross Connects Add The Add Cross Connection screen will open By default the...

Page 40: ...Light Connect inactive placeholder for planned functionality Connection Name specifies an alias for the connection the default value is inport outport or inport outport 4 Click the Less button in the...

Page 41: ...port will change from a blank white square to a pale green square containing the word IN It will also appear in the FROM ID field in the upper left corner of the screen 8 Click one of the free output...

Page 42: ...h button to clear the port selections and return to the All tab of the Add Cross Connection screen If the new connection is Bidirectional 4 ports 2 input 2 output will be highlighted blue on the Add C...

Page 43: ...of 63 The Connection Detail and Delete Connection options will appear only if the selected ports are connected blue Right clicking unconnected white ports will only display the View Port Details opti...

Page 44: ...nection the color of the ports for any connection displayed on the Add Cross Connection screen will change from blue to green after the connection has been activated Deactivating the ports in a connec...

Page 45: ...INput and OUTput Power Insertion Loss Alarm State Administrative Status AS Operational Status OS and Operational Capability OC on all currently configured connections Possible values for the Alarm Sta...

Page 46: ...reen will open 3 Click Export CSV in the upper right corner of the screen to export the listed information as a CSV comma separated values file 4 Click the down arrow at the right of the Group Filter...

Page 47: ...lay the Cross Connection Details screen for that connection e g 1 2 1 1 2 5 The Connection Details section of the screen provides information on the Alarm State CL MN MJ or CR of the connection its Ad...

Page 48: ...n will appear on the Cross Connections Summary screen see below and the Circuit ID information for both halves of the connection will appear on the Cross Connection Details screen see below 2 Click th...

Page 49: ...ct configurations saved on the OCS The following steps describe how to access and use the system s Save Recall functionality 1 Log into the WebGUI 2 Navigate the following path Cross Connects Save Rec...

Page 50: ...k any column header in the Save Recall table to sort the information in all rows and columns either up or down according to the numerical or alphabetical sequence of the information in the selected co...

Page 51: ...currently configured on the system 3 Click Export CSV in the upper left corner of the screen to export the listed information as a CSV comma separated values file 4 Click the Choose File button to sel...

Page 52: ...Ports Summary Port Details The following steps describe how to access and use the WebGUI s Port Details screen 1 Log into the WebGUI 2 Navigate the following path Ports Summary The Port Summary scree...

Page 53: ...enance OS the operational status of the incoming outgoing ports possible values are RDY ready OOS Out of Service and OOS NP Out of Service Not Provisioned Not Provisioned Not Connected OC the operatio...

Page 54: ...k the appropriate button at the bottom of the Port Detail screen to perform one of the following actions Back returns the user to the Port Summary screen Save saves the latest changes made to the sett...

Page 55: ...w port group in the Port Group Name field in the upper left corner of the screen 4 In the Member Ports section of the screen click any ports shown in the Non Members list to select them Selected ports...

Page 56: ...WebGUI Quick Start Guide Doc Part No 460185 00 July 28 2015 Rev 0 2 Page 56 of 63 5 Click the right pointing arrow between the port lists The selected ports will move from the Non Members list to the...

Page 57: ...button to cancel the port selections and reset any threshold changes to their original settings If you click Save a dialogue box will appear asking you to confirm that you want to add the new port gr...

Page 58: ...ndividual Ports and Port Count for each port group on the OCS 3 Click the Port Group Name or Port Count column header to sort the information listed in all rows and columns either up or down according...

Page 59: ...fy button at the bottom of the screen to remove the selected port s from the Port Group 7 Make any desired changes to the threshold settings displayed in the Port Group Modify Details section of the s...

Page 60: ...nter AliasClassificationEnabled 1 in flash config swconfig cfg by either of the following methods a Via the vim utility on the shell or b Copy swconfig cfg from the switch to your desktop make the spe...

Page 61: ...section of the screen type the appropriate alias information in the Port In Alias and Port Out Alias fields 5 Click the Save button at the bottom of the screen to save the information 9 3 Setting Ali...

Page 62: ...n A dialogue box will appear listing the following options Connection Detail Delete Connection and View Port Details 4 Click the View Port Details option The Port Detail screen for the selected port w...

Page 63: ...CS WebGUI Quick Start Guide Doc Part No 460185 00 July 28 2015 Rev 0 2 Page 63 of 63 7 To verify the changes go the Port Summary screen at Home Ports Summary to see the newly configured port aliases d...

Reviews: