Included

About this manual

This document is a short manual for the iSolar DL3. 
This short manual contains information about the fol-
lowing topics:
•  Installation
•  Electrical connection
•  Operating controls
•  Menu
•  Using the SD card
A detailed manual with the complete information 
about the web interface can be found on the included 
CD. 

Installation

ATTENTION!

ESD damage!
Electrostatic discharge can lead to 
damage to electronic components!

 

Î

Take care to discharge prop-
erly before touching the in-
side of the device. To do so, 
touch a grounded surface 
such as a radiator or tap!

ATTENTION!

Short circuit!
A short circuit can lead to damage 
to electronic components!

 

Î

Close the housing before 
establishing the mains con-
nection!

Initial installation must be effected by the system in-
staller or qualifi ed personnel named by the system 
installer.

If one of the items mentioned below is missing or de-
fective, please contact your distributor:

1

iSolar DL3

2

Mains adapter

3

Interchangeable mains adapter plugs 
(EURO, UK, USA, AUS)

4

VBus

®

 cable

5

Network cable (CAT5e, RJ45), 1 m

6

Wall plugs and screws

7

Terminal block for extending the VBus

®

 cable

8

USB adapter cable

9

CD with ServiceCenter software and detailed 
manual

10

Short manual 
(picture similar to original product)

11

SD card

1

2

3

8

5

6

7

9

10

4

11

Summary of Contents for iSolar DL3

Page 1: ...ank you for buying this product Please read this manual carefully to get the best performance from this unit Please keep this manual carefully Mounting Electrical connection Operating controls Manual...

Page 2: ...o au thorised skilled personnel Only qualified electricians should carry out electrical works Description of symbols WARNING Warnings are indicated with a warn ing triangle They contain information on...

Page 3: ...uts possible Current loop interface 0 4 20mA BACnet functionality for BACnet conform trans mission and reception of data Data logging onto SD card Technical data Housing plastic PC ABS and PMMA Protec...

Page 4: ...urface such as a radiator or tap ATTENTION Short circuit A short circuit can lead to damage to electronic components Close the housing before establishing the mains con nection Initial installation mu...

Page 5: ...losed wall plug and screw leav ing the head protruding Hang the housing from the upper fastening point and mark the lower fastening points centres 180 mm Drill 2 holes 6 mm and insert the wall plugs F...

Page 6: ...minal block included and a common two wire cable VBus connection at the terminals 1 2 VBus connection 1 slave 3 4 VBus connection 2 slave 5 6 VBus connection 3 slave 7 8 VBus connection 4 slave 9 10 V...

Page 7: ...nged in different ways An option can be selected by pressing buttons 1 and 2 and then confirming by pressing button 3 Now the option can be activated By pressing buttons 1 and 2 Yes can be selected to...

Page 8: ...has been assigned to the DL3 the IP address and the house globe symbol appear as soon as the network cable has been connected 5 4 3 VBus display In the VBus display VBus information about the VBus de...

Page 9: ...esired VBus connection by pressing buttons 1 and 2 and confirm with button 3 To activate the monitoring of the VBus connec tion select Yes To deactivate the monitoring of theVBus connection select No...

Page 10: ...ging In the Logging sub menu the following adjustments can be made Interval Logging type SD card only if an SD card has been inserted into the SD card slot When Interval has been selected the logging...

Page 11: ...lows Select the menu item Erase data by pressing buttons 1 and 2 and confirm with button 3 To erase all data confirm the security enquiry Erase by selecting Yes and confirming by press ing button 3 Th...

Page 12: ...4 00 Recover Now Erase Erase data Yes No No Reset Yes No No Version 5 8 SD memory card slot SD memory card slot The SD memory card slot is located at the front of the device By means of the SD memory...

Page 13: ...ogged data onto an SD memory card The data are stored as aVBus format file and can be read out on a computer using the ServiceCenter software 2 Export logged data onto a computer over the web interfac...

Page 14: ...en 14 Note...

Page 15: ...en 15 Note...

Page 16: ...for the completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false informa...

Reviews: