background image

Page 6

Getting Started

WATERFALL VALVE

The 

SALINA, MAKENA

MARTINIQUE, 

SEYCHELLES & REUNION

 

spas are equipped 

with a cascading waterfall feature. It is activated by 

pressing the "JETS" button and turning the valve 

located on the front interior wall counterclockwise. 

The flow is regulated by turning the waterfall valve 

to the desired position.

AIR CONTROLS

Each jet system has its own air 

control. These allow you to change 

the power of the jets by regulating the 

amount of air that is mixed with the 

water coming out of the jets. 

QUICK START-UP INSTRUCTIONS

BEFORE YOU FILL YOUR SPA

Make sure your spa has been properly installed per all local codes, this 

includes the location of the spa, the foundation of the spa as well as 

the electrical installation of the spa. Installation instructions in the form 

of a Pre-Delivery Instruction booklet can be obtained from either your 

CALDERA

 dealer or online.

DO:

•  Know which water treatment system you will be using and make sure 

you have necessary chemicals available. Read all of the instructions 

that come with the system.

•  Have 

FRESHWATER

 

 5-way Test Strips Available.

•  Have 

FRESHWATER

 

 Salt Test Strips Available if using the Salt system.

•  Have pH/Alkalinity Up & Down available.
•  Know the "Hardness" of your water, contact your dealer to help you 

with this information. See Water Quality and Maintenance for more 

information.  

IMPORTANT:

 The spa can be filled with “softened” water as long as 

the calcium hardness parameters (pg. 2) are maintained.

•  Purchase the Clean Screen

 pre-filter to remove unwanted 

contaminants from the tap water. This is recommended, not required.

DON'T:

•  Power up the spa until it has been filled with water!

 

Power to the 

spa automatically activates critical components within the spa, such 

as controls, heater, circulation pump, and other systems. If power 

is supplied to these components prior to the spa being filled, the 

components will be damaged, and this may result in a non-warranty 

component failure.

•  Fill the spa with hot water or cold water with cold water temperature 

below 10º C (50º F)! Tripping of the high-limit thermostat may result 

causing your spa to stop functioning.

START-UP

Your 

CALDERA

 spa has been thoroughly tested during the 

manufacturing process to ensure reliability and long-term customer 

satisfaction. A small amount of water may have remained in the 

plumbing after testing and, as a result, may have spotted the spa shell 

or the spa siding prior to delivery. Before filling the spa, wipe the spa 

shell clean with a soft rag. The following instructions must be read and 

followed exactly to ensure a successful start-up or refill.

CAUTIONS

•  Do NOT fill the spa with hot water, 

as tripping of the high-limit 

thermostat may result.

•  DO NOT CONNECT POWER TO AN EMPTY SPA. 

Power to the 

spa automatically activates critical components within the spa, such 

as controls, heater, and other systems. If power is supplied to these 

components prior to the spa being filled, the components will be 

damaged, and this may result in a non-warranty component failure.

•  DO NOT 

use your spa after filling until all of the steps listed below are 

completed.

•  DO NOT 

add chlorine if treating your spa with polyhexamethylene 

biguanide (Biguanide, PHMB, eg. BaquaSpa 

®

) sanitizer.

•  Before filling your spa for the first time, remove the equipment 

compartment door and check to ensure that the unions on either side 

of the pump(s) and heater are hand-tight. 
Door Panel Removal - see inside back cover:
a.  Remove the 2 screws on the bottom of each corner.
b.  Find notches in bottom of panel, place fingers on one side 

and center notch. Slightly pull on bottom side panel to release 1st 

clip. Move over to other side and center notch and pull on bottom 

to release 2nd clip, then lower and remove panel.

1.  

CLOSE DRAIN, remove the filter compartment cover, skimmer 

basket, weir, and filter. 

Fill your spa through the filter compartment 

using the 

CLEANSCREEN

 pre-filter that attaches to your garden 

hose. The water level of your spa should be maintained at a level 

one inch above the highest jet in the spa. Reinstall the filter and then 

the skimmer basket, and weir once the spa is filled.  

2.  

AFTER THE SPA HAS BEEN FILLED

 with water and the 

equipment compartment door is secured, power must be applied 

to the spa. 
•  FIRST activate power to the subpanel from the main house 

panel.

•  NEXT open the door of the electrical subpanel and reset the RCD 

breaker.

•  FINALLY, close and secure the subpanel door.

3.  

TO CHECK THE OPERATION OF THE JET SYSTEM 

and to 

purge any remaining air from the heating system complete the 

following steps:
•  Press the soft button next to 

Jet Max

 to place both jet pumps on 

High. 

•  Once the jet system is fully operational (as indicated by strong, 

non-surging jets), priming of the spa is complete

•  To turn off the jets, press the soft button next to 

All Off

 on the 

home screen to turn all functions off simultaneously

•  If you do not feel a steady stream of water from your jets, 

refer to the instructions for priming the pump in the SPA 

TROUBLESHOOTING section.

IMPORTANT:

 Be sure that the diverter is in the middle position.

Summary of Contents for Makena

Page 1: ...PARADISE SERIES 2 0 1 9 O W N E R S M A N U A L 5 0 H z...

Page 2: ...ERIAL NUMBER ___________________________ COVER SERIAL NUMBER _______________________________ In most cities and counties permits will be required for the installation of electrical circuits or the con...

Page 3: ...ET SYSTEM MENU 22 REUNION JET SYSTEM MENU 23 KAUAI JET SYSTEM MENU 24 SPA CARE AND MAINTENANCE FILTER MAINTENANCE 25 FILTER CARTRIDGE REMOVALAND CLEANING INSTRUCTIONS 25 DIVERTER VALVE MAINTENANCE 25...

Page 4: ...ss remote is permitted and acceptable Do not connect any auxiliary components for example cable additional speakers headphones additional audio components to the audio system unless approved by Watkin...

Page 5: ...evels for your CALDERA spa are Free Available Chlorine 1 5 ppm Total Alkalinity 40 120 ppm Water pH 7 2 7 8 Calcium Hardness Standard 75 150 ppm Salt System 25 75 ppm Refer to Water Quality and Mainte...

Page 6: ...over the telephone by an Authorized Service Technician SPA SHELL Your CALDERA spa has an acrylic shell Stains and dirt generally will not adhere to your spa s surface Asoft rag should easily remove mo...

Page 7: ...ition of the nozzle 7 The Euro Directional jets with eyeball nozzles deliver a direct more focused massage 8 The Euro Pulse KAUAI model only jets feature a special insert that creates a soft pulsating...

Page 8: ...ets allow you to regulate the force of the massage Rotate the fascia ring counter clockwise to reduce the force or clockwise to increase the force Notice that turning off the flow to some jets increas...

Page 9: ...elivery Before filling the spa wipe the spa shell clean with a soft rag The following instructions must be read and followed exactly to ensure a successful start up or refill CAUTIONS Do NOT fill the...

Page 10: ...n using the FRESHWATER Salt system the Calcium Hardness must be between 25 75 ppm if hardness is above 75 ppm use VANISHING ACT see pg 11 IMPORTANT Activate the Clean cycle Press the soft button next...

Page 11: ...in concentrated form Always observe the following guidelines Allow only a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities spec...

Page 12: ...use FRESHWATER pH Alkalinity Down sodium bisulfate To raise the pH level use pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to location and user to user there...

Page 13: ...rts water and sodium chloride salt into chlorine sanitizer The FRESHWATER Salt System is compatible with chlorine based systems and chemicals Although the system is reduced maintenance it is not autom...

Page 14: ...VANISHING ACT calcium remover will be placed up over Use the circle to determine location a Press OPTIONS hard button on the Control panel Press the soft button next to Set Up Press the soft button n...

Page 15: ...limited warranty Floating dispensers can become trapped in one area and cause an over sanitization or release large chunks of sanitizer that very quickly chemically burn the shell and cover DON T Use...

Page 16: ...urine perspiration etc Chloramines can cause eye irritation as well as having a strong odor Unlike bromamines chloramines are weaker slower sanitizers Chlorine An efficient sanitizing chemical for sp...

Page 17: ...range If you increase or decrease the temperature setting of the spa the ready indicator will turn off until the water temperature reaches the acceptable range for the new temperature setting A flashi...

Page 18: ...Celsius Press the soft button next to the F C to choose one or the other LOCKING FEATURES The two locking features Temperature Lock and Spa Lock are activated at the main control panel Once activated...

Page 19: ...hut down The circulation pump will remain on for approximately 5 minutes pushing water through the heater to cool it down Both heater and circulation pump will then remain off for eight hours The summ...

Page 20: ...ake a few seconds to turn on or off TO PAIR BLUETOOTH 1 Press the Function SET soft button 3 times to advance to the Enter Setup screen Press the Enter Setup soft button to advance to the Setup Source...

Page 21: ...le soft button to advance to the SETUP Tone Bass screen Press SETUP Tone Bass soft button to advance to the SETUP Balance screen Press SETUP Balance soft button to advance to the SETUP Subwoofer scree...

Page 22: ...NU A Diverter in position a 2 Euro Directional jets b 1 VERSASSAGE jet Located in UltraMassage lounge c 6 Sole Soothers d 3 VERSASSAGE jets e 6 Euro Directional jets COMBINATION JET SYSTEM Diverter in...

Page 23: ...HORIA jet b 2 Euro Directional jets c 2 Euro Directional jets d 1 VERSASSAGE jet COMBINATION JET SYSTEM Diverter in mid position activates both menus in systems 1 2 SYSTEM 1 MENU B Diverter in positio...

Page 24: ...Diverter in position Located in ULTRAMASSAGE lounge front a 6 SOLE SOOTHERS b 3 VERSASSAGE jets c 6 Euro Directional jets d Waterfall COMBINATION JET SYSTEM Diverter in mid position activates both me...

Page 25: ...et Located in ULTRAMASSAGElounge c 2 Euro Directional jets d 3 VERSASSAGE jets a a b c d SYSTEM 1 MENU A Diverter in position Located in ECSTASEAT a 14 Euro Directional jets b 1 ADAPTAFLO jet c Waterf...

Page 26: ...E jets b 1 ADAPTAFLO jet c Waterfall Located in ECSTASEAT d 2 Euro Directional jets e 2 VERSASSAGE jets SYSTEM 2 MENU A Diverter in position Located in front right seat a 4 Euro Directional jets b 2 V...

Page 27: ...TASEAT d 8 Euro Directional jets e 2 EURO PULSE jets SYSTEM 1 MENU A Diverter in position Located in ULTRAMASSAGElounge a 6 SOLE SOOTHERS b 3 VERSASSAGE jets c 6 Euro Directional jets Located in LUMBA...

Page 28: ...ome difficult to turn it is likely that sand or grit is lodged inside the valve body It is very important that this debris is removed as soon as possible to avoid damage to the valve To clean the valv...

Page 29: ...y warranty It is strongly recommended that you contact your local dealer to perform this service 1 Drain your spa following the Draining Your Spa section in the owner s manual 2 Remove the filter cart...

Page 30: ...Most household chemicals are harmful to your spa s shell Always rinse off any spa shell cleaning agent with fresh water SPA SKIRT When cleaning the skirt of your spa use only a soft cloth or sponge w...

Page 31: ...EUNION spas require a dual electrical service using a 16 25 amp breaker and wired per the illustration found on the next page Additionally one main disconnect switch with at least 3mm separation betwe...

Page 32: ...MM 40 Amp Electrical Requirements HOT HOT NEUTRAL NEUTRAL GROUND RCD BREAKER Tahatian 7 2 3 4 5 6 8 1 EQUIPMENT COMPARTMENT The illustration below is to be used as a reference only your spa may look d...

Page 33: ...y rot mildew or other problems Check for airborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An arch...

Page 34: ...ane will be required Don t be alarmed The crane has a truck mounted boom which can fit right in your driveway It is run by a licensed and insured operator For a charge the crane operator will lift you...

Page 35: ...dead weight found in the spa specification chart WARNING The MAKENA and SALINA must not be shimmed in any manner MAKENA AND SALINA DIMENSIONS NOTE All dimensions are approximate measure your spa befor...

Page 36: ...upport the dead weight found in the spa specification chart WARNING The MARTINIQUE must not be shimmed in any manner MARTINIQUE NOTE All dimensions are approximate measure your spa before making criti...

Page 37: ...ck reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart WARNING The SEYCHELLES must not be shimmed in any manner Installation 33 83 9...

Page 38: ...10 cm 4 thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart WARNING The REUNION must not be shimmed in any manner 33 83 9 cm...

Page 39: ...support the dead weight found in the spa specification chart WARNING The KAUAI must not be shimmed in any manner KAUAI NOTE All dimensions are approximate measure your spa before making critical desi...

Page 40: ...high limit tripping are discussed in the previous section If the spa is not heating the red and green lights are blinking but the pump and light are operating then the pressure switch may be open Open...

Page 41: ...d warranty lasts Under no circumstances shall Watkins Wellness or any of its representatives be held liable for injury to any person or damage to any property however arising Some states do not allow...

Page 42: ...set too low Spa cover improperly positioned Dirty filter Summer Timer on Set control panel to a higher temperature Align spa cover Clean filter Turn summer timer mode to off position Pump motor will...

Page 43: ...notch on other side of panel and place fingers inside the notch and center notch Pull panel away from spa lower panel and store in a cool and shaded place NOTE It may be possible when pulling out the...

Page 44: ...s 226 cm x 193 cm 7 5 x 6 4 88 cm 34 5 m 3 000 1 080 liters 285 gallons 420 kg 930 lbs 1 895 kg 4 180 lbs 540 kg m 110 lbs ft 220 240 volt 16 25 amp Single phase RCD protected circuit SEYCHELLES Model...

Reviews: