Install LMU Controller

1. 

Select an LMU Controller modem installation location that meets the following requirements:

CAUTION: Installation Requirements 

• 

The LMU Controller must be installed within the range of the cables distance.

•  Install within the vehicle, close to the DVR if possible.
•  Install where LEDs can be seen if necessary.
•  Install in the front of the vehicle.
• 

Route the wiring and cables away from sharp edges that might damage the insulation.

•  Avoid sharp bends in the cable.

Installation Requirements

Location

The LMU contains a built-in GPS antenna, which can be obstructed by metal objects. The best place 

to mount the LMU for optimal GPS reception is on top of the front dash panel, with the label facing 

out towards the sky.

Choose a dry location with easy access to the electrical panel and cable connections to mount the 

LMU Controller.

Install the LMU Controller away from any place where tampering with the device or cable connections 

may occur.

Surface

Do not mount the LMU Controller to a plastic panel or other surface that is subject to constant 

vibration.

Clearance

Allow sufficient clearance of at least six (6) inches in front of the LMU Controller and two (2) inches 

on each side for easy access and removal of cable connectors and ports.
Allow sufficient clearance behind the LMU Controller for power cables.

Harnesses

Provide enough slack on the power cable to prevent any force from being exerted on the connectors. 

A single 4-inch diameter loop is sufficient.

2.  Using the supplied alcohol wipe pad, clean the vehicle surface where the LMU Controller will be installed. 

3. 

Peel the protective cover from the velcro backing on the LMU Controller. Be careful not to touch or allow any foreign 

material to come in contact with the exposed adhesive.

4.  Attach the LMU Controller to the vehicle.

5. 

Clip the 1x2 Microfit connector from the end of the alarm button extension cable.

6. 

Connect the alarm button’s red and black wires to the extension cable’s red and black wires with the supplied crimps.

7. 

Connect all power, alarm, GPS, and Stop Arm cabling to the LMU Controller 20 pin harness, and if you are connecting 

the LMU Controller to a DVR, connect the AUX 1 from the LMU Controller harness to the supplied adaptor cable, 

using the appropriate diagram (presented in the following pages) to guide you through the process.

Summary of Contents for LMU 2630MB

Page 1: ...Safe Fleet May 2022 All rights reserved Part 700 1284 R1 For LMU Model 2630MB VLP LMUE1Y1 LMU Controller Installation Guide...

Page 2: ...Safe Fleet May 2022 All rights reserved Part 700 1284 R1 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 3: ...4 Kit Contents 4 Installation 5 Complete Installation Record 5 Install LMU Controller 6 LMU Controller LEDs 10 Operation Status 10 Provisioning the LMU Controller 11 Troubleshooting 11 Specifications...

Page 4: ...needs to have firmware version 2 0 or higher This installation must be performed by a professional with approval from Safe Fleet Overview The required and optional contents of a typical installation...

Page 5: ...eet or the customer the installer gets an Installation Record see sample below with the Device ID column populated The Device ID is the 10 digit ESN number on the LMU Controller label 2 Fill in the re...

Page 6: ...r other surface that is subject to constant vibration Clearance Allow sufficient clearance of at least six 6 inches in front of the LMU Controller and two 2 inches on each side for easy access and rem...

Page 7: ...e wires LMU Controller VLP LMU26M LMU Controller Harness LED end Comm LED GPS LED 1x5 Microfit connector 2x2 Microfit connector To DVR options Pin 1 Pin 1 Pin 11 Pin 11 Pin 10 Pin 10 Pin 20 Pin 20 GPS...

Page 8: ...it connector 1x4 Microfit connector Pin 1 Pin 1 Pin 11 Pin 11 Pin 10 Pin 10 Pin 20 Pin 20 Pin 16 Alarm Button black wire active low Pin 3 Stop Arm blue wire active high Orange wire from pin 12 to red...

Page 9: ...wire active low Pin 3 Stop Arm blue wire active high Orange wire from pin 12 to red on extension cable Pin 12 Alarm Button orange wire active low Alarm Button 060 0061 060 1232 20ft 6 1m Extension Har...

Page 10: ...MU Controller indicate operation status and display operation mode conditions as described below LED Status Indicators Comm LED Orange Condition GPS LED Green Condition Off Modem Off Off GPS Off Slow...

Page 11: ...e to provision the LMU To access the Provisioning LMU tutorial click here Troubleshooting Symptom Possible Cause Solution LMU Controller will not start The power cabling may not be completely connecte...

Page 12: ...50 ohm SMA female connector GMS Antenna 50 ohm SMC female connector 50 ohm SMC female connector Power Signals 20 pin Micro Fit female connector 20 pin Micro Fit female connector Environment Operating...

Page 13: ...l PTsupport safefleet net Warranty And End User License Agreement Complete warranty details are available at http www seon com documents Seon Warranty pdf Product Information For product information a...

Reviews: