Appendix
Appendix
Troubleshooting Procedures
If Grill Fails to Operate Properly:
1.
Turn off gas at source, turn the Control Knobs to the ‘OFF’ position and wait five minutes before trying
again.
2.
Check gas supply at a connections.
3.
Repeat lighting procedure and if grill still fails to operate properly, turn off gas at source, turn the control
knobs to the off position and wait for the grill to cool down and check the following:
Cannot Ignite
1.
If the burner does not turn on, use the following procedure with Figure 51.
•
Check for proper position of sparker tip should be pointing forward towards the front of the brass burner.
•
Make sure there is a blue spark at the electrode tip to the brass burner.
•
Make sure igniter wire is connected firmly to the valve ignition device and electrode.
•
Make sure valve orifice is free of any debris, dust or grease.
•
Make sure valve orifice is aligned inside the front hole of the brass burner.
2.
If there is no spark at all, replace th electrode or igniter wire.
Note: Turn off the gas at the source while troubleshooting.
Figure 51
Problem: Misalignment of burner tube(s) over orifice(s)
Solution:
Reposition the burner tube to properly seat over orifice.
Problem:
Obstruction In Gas Line
Solution:
Remove fuel line from grill. Do not smoke or perform any maintenance in the vicinity of an open
flame. Open gas valve for one second to blow out any debris. Close off gas valve and reconnect
fuel line securely.
Page 52
2005 Spa Owner's Manual
7/21/2005
Summary of Contents for 2005 Spa
Page 1: ...LTR20051000 Rev D 7 21 2005...
Page 31: ...Operating Your Barbecue 2005 Spa Owner s Manual Page 27 7 21 2005...
Page 62: ......
Page 63: ...LTR20051000 Rev D 7 21 2005...