INNOVATION TOTAL LITE Rev. 11 05/2018
63
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Innovation Series’ Total Lite
C
le
an
in
g
an
d
San
it
iz
in
g
7.7.2 Soluble Canisters
Soluble Whipper Assembly
Frequency: weekly or every 200 cycles
If there is product accumulation, remove the soluble
whipper assembly for manual cleaning under hot
water.
1. Remove the tube from the base.
2. Lift the funnel. Remove the whipper chamber and
the propeller, then twist off the whipper base.
3. Clean all parts and gaskets with hot water. Use
the small brush for tubes if necessary.
4. Air dry completely.
5. Reinstall all parts in reverse order.
6. Order a large beverage of each soluble to ensure
that all parts and switches are working properly.
Soluble Canisters
Frequency: monthly or every 1,000 cycles
It is recommended to remove, empty and clean the
soluble canisters every month to avoid powder to
accumulate on the walls of the canisters and alter
the beverage quality.
1. Open the unit’s door and remove the plastic top
lid of the machine.
2. Pull each canister through the top of the brewer
to disengage it from the motor and transmission.
3. Clean and sanitize under hot water and air dry
completely.
4. Reinstall all parts and reload products in the
canisters.
5. Order a large beverage of each soluble to
confirm that all parts and switches are working
properly.