6.5.3 Brew Cycles & Fast Settings Subtab (Continued)
Brew Cycle Settings Interface (Continued)
Move 3
Position where the piston stops before dispensing the coffee into the cup.
A setting too high will prematurely open the brew chamber, causing a mess of wet
coffee grounds inside the machine.
A setting too low will not pull all coffee through the filter.
This setting must be changed with care.
Pause 3
Pause time before the brew chamber opens. If there are wet coffee grounds on the filter paper
at the end of the cycle, increasing this setting might solve the issue.
20 units = 1 second.
Pause 4
Brew group drain time. This setting must be high enough to empty the brew group at the
end of the cycle.
20 units = 1 second.
This interface is used to set all coffee drinks’ brew cycles. There is no individual
setting table per recipe.
Automated Fast Settings of All Drinks Interface
1. This section is used to select desired cup
size. Slide the coffee cup icon from 7 oz to
20 oz.
2. This table is used to set the quantity of
coffee (in grams) per water once.
3. This table is used to set the quantity of
soluble powder (in grams) per water once.
4. These buttons are used to assign the settings to a cup size (small, medium and large).
All drinks will automatically be set under the Liquids & Ingr. subtab.
The fast setting does not affect the Iced Coffee, Long Espresso, Energy Shot,
Hot Shot Blend, Café Latte and Cappuccino drink recipes, which can only be edited
manually.
1