INNOVATION TOTAL LITE Rev. 11 05/2018
21
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Innovation Series’ Total Lite
In
it
ia
l S
e
tu
p
4.9
Water Temperature
This equipment has a coffee brewing setpoint of 200 °F water temperature to ensure a consistent
beverage quality. There is a +/- 2 °F tolerance.
This data represents an average and will not correspond to the temperature of a manual
measurement. The actual water temperature fluctuates because cold water is added to the
tank after every beverage delivery and time is needed to heat the new incoming water up to the
setpoint.
Water’s brewing temperature can also be taken manually by ordering a cup of hot water and
measuring its temperature with a thermometer. There may be a slight difference from the tank
reading. This is normal.
If the temperature measurements show a large temperature differential, verify that the tank is clean
and not obstructed by mineral deposits and scale.
Unit Safety Measures
In the event of a temperature probe failure, water in the tank might start to boil. This will cause it to
overflow into the overflow cup and will automatically shut the machine off.
Electronic
thermostat
Access by the back of the machine.
Temperature can be set by the user in the System 1 tab (see section 6.6.1).