INNOVATION TOTAL LITE Rev. 11 05/2018
www.cafection.com 800-561-6162
64
SERVICE & INSTALLATION MANUAL for Innovation Series’ Total Lite
7.7.3 Brew Group
Brew Chamber and Funnel
Frequency: weekly or every 200 cycles
1. Place a large cup or container under the dispensing
nozzle to collect the hot rinse water.
2. Perform several rinse cycles (see section 7.1).
3. Remove the brown tube from its support. Remove
the brew chamber’s funnel to dislodge coffee residue
trapped underneath it and rinse it under hot water.
4. Reinstall the funnel and the tube in its support.
Make sure the tube is against the wall of the funnel.
Water must form a circular motion when being
dispensed.
5. Order a large coffee to ensure that the brew
chamber is working properly.
Warning! Place a container large enough (size specified on the screen). Water is
HOT.
The funnel should be cleaned weekly or more often if
needed.
To clean the funnel, follow steps 3 to 5.
Brew Group Assembly
Frequency: monthly or every 1,000 cycles
In order to maintain optimal performance of the brew
group assembly, it is recommended to remove it from
the unit, clean it and rinse it under hot water.
1. Open the brewer’s door and remove the front panel.
2. Cut the filter paper with scissors on both sides of the
brew chamber.
3. Push the locking pin down to release the brew group
and pull it forward.
4. Rinse the brew group thoroughly under hot water to
remove visible soil.
5. Remove the funnel from the brew chamber and rinse
it thoroughly under hot water.
6. Air dry completely before reinstalling the parts.
7. Order a large coffee to ensure that the brew group is
working properly.
Mixing
chamber
Brew chamber
funnel
Mixing chamber
tube retainer
C
le
an
in
g
an
d
San
it
iz
in
g