SERVICE & INSTALLATION MANUAL for Innovation Series’ Total Lite
4.4
Leveling the Equipment
For optimal performance of the equipment, it is important to ensure that it is leveled.
Avoiding to do so can create variations in product delivery.
1. Place a level on the top of the equipment.
2. Adjust the four (4) threaded level legs of the equipment to reach a leveled position.
4.5
Adjusting the Tank Overflow Float
The overflow cup is a safety feature. If the water tank overflows, the extra water will leak
in the pipe down to the overflow cup. If there is too much water, the float will go up and
deactivate the switch. The machine will then stop automatically.
It is important to verify that the float is positioned properly in the overflow cup because it
can move around in transportation. If the float is not properly in place, the switch will not be
activated and the unit will automatically shut down sensing an overflow situation.
It is important to verify that the overflow cup is in place with the highest side in front and well
secured with the green tape. If the cup needs to be removed, make sure that it is replaced
with the highest side facing the front and the overflow tube in the cup. Fasten it in place with
tape. This will ensure that the float will work properly and activate the overflow switch if a
problem occurs.
Cup
Hole in the exit
of the tube
Switch deactivated
The unit is on.
Overflow switch activated
The unit shuts down.
Highest side
facing front
Location of the cup
in the brewer