3.8
Water Temperature
This equipment has a water temperature setpoint of 200 °F to ensure a consistent beverage
quality. There is a +/- 2 °F tolerance.
This data represents an average and will not correspond to the temperature of a manual
measurement. The actual water temperature fluctuates because cold water is added to the
tank after every beverage delivery and time is needed to heat the new incoming water up to the
setpoint.
Water’s brewing temperature can also be taken manually by ordering a cup of hot water and
measuring its temperature with a thermometer. There may be a slight difference from the tank
reading. This is normal.
If the temperature measurements show a large temperature differential, verify that the tank is clean
and not obstructed by mineral deposits and scale.
Unit Safety Measures
In the event of a temperature probe failure, water in the tank might start to boil, causing it to
overflow into the overflow drip tray. The machine will be automatically shut off, but the screen will
remain ON.
If the heating element goes ON and there is no water in the tank, the heating element power
supply is cut out by the water tank safety part. The water tank needs to be opened to detect any
damaged or defective part. Check the following parts: motors behind the water tank, wires around
the water tank, water inlet and water tank parts (inside the tank).