24
Setup
Optional: Connect External Air
Using the External Air kit allows METIman to be run by an external air source rather than the
internal compressor. The air hose can be connected to or disconnected from METIman at
any time. When the external air pressure is sensed, the pump internal to METIman turns off
automatically. When you want to make METIman mobile again, simply disconnect the hose.
The optional External Compressed Air Kit consists of a flexible 30 ft (9 m) hose attached to a
preset air regulator and a fitting for air compressors and adapters for wall or tank air.
To connect the air hose:
Connect the External Compressed Air Kit to a CAE Healthcare compressor using
1.
the Quick Coupler attached to the regulator. (Other compressed air sources have
their own adapters. Locate the adapter for your compressed air source.)
Connect the other end of the External Compressed Air Kit to the
2.
EXTERNAL AIR
port on the left shoulder.
METIman Prehospital’s Left Shoulder
METIman Nursing’s Left Shoulder
The
EXTERNAL
AIR
port
The
EXTERNAL
AIR
port