34
VENUS PLUS - GIOIA-2
EN
ALARM
CAUSE
SOLUTION
INTERVENTION
AL 8 - FAILURE
DEPRESS
Obstructed exhaust
The exhaust chimney is partially or tatally obstructed.
Please contact a Specialized Stove-repairer who checks
the stove exhaust up to the chimney pot. Please have it
immediately cleaned. It can be harmful to health to run
the stove with the obstructed chimney.
Faulty exhaust fan
The pellets can burn also thank to chimney flue depression
without the aid of the exhaust fan. Have the exhaust fan
immediately replaced. It can be harmful to health to run
the stove without exhaust fan.
Obstructed outlet
connector
Clean the outlet connector.
Faulty pressostat
Clean the pressostat.
Faulty mother board
Replace the mother board.
Extreme chimney lenght
Contact a Specialized Stove-repairer and check that the
exhaust chimney is in accordance with the regulations:
.
Adverse weather
conditions
In case of strong wind there can be a negative pressure
to the chimney. Check it and start the stove up again.
AL 9 - DOOR
OPEN
The fire door is not
correctly closed
Close the fire door correctly and check if the gaskets
are damaged. (In this case have it replaced by an
Authorized Technician).
Fire door microswitch
faulty or out of order
Replace the fire door microswitch.
14.2
PROBLEM SOLVING
Before of every testing and/or intervention of the Authorized Technician, the Autorized
Technician personally has the duty to verify that the parameters of the electronic board
meet those of the reference table you own.
In case of doubts regarding the running of the stove please contact ONLY the Autorized
Technician in order to avoid irreparable damages!