Cadel TESIS 16 AIRTIGHT T2 User Manual Download Page 23

new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2

23

TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED

If the product is NOT used as described in this instruction manual, the manufacturer declines all liability for 

any damage caused to persons and property. The manufacturer furthermore refuses to accept responsibility 

for damage to persons and property arising from the failure to observe all the rules contained in the manual 

and in particular:

• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning 

and repairs.

• Do not tamper with the safety devices.

• Do not remove the safety devices.

• Connect the product to an efficient smoke expulsion system.

• Verify that the room in which the appliance will be installed is adequately ventilated.

The product can be started-up and the automatic function of the probe restored only after having eliminated 

the cause that triggered the safety system. This manual will help you understand which anomaly has occur-

red, and explain how to intervene according to the alarm message displayed on the appliance.

10.14  ALARM ALERTS

Whenever an operating condition other than that designed for the regular operation of the boiler occurs, there is an alarm condition.

The control panel gives information on the reason of the alarm in progress. A sound signal is not envisioned for alarms A01-A02 

only so to PANEL ALERTnot disturb the user in the event of pellets running out in the hopper during the night.

PANEL ALERT

TYPE OF PROBLEM

SOLUTION

A01

The fire does not ignite.

Check whether the brazier is clean / level of pellets in the 

hopper.

A02

The fire goes off abnormally.

Check the level of pellets in the hopper.

A03 Thermostat 

alarms

The temperature of the pellets hopper or the 

water temperature exceed the envisioned safety 

threshold. 

Wait for the cooling stage to end, cancel the alarm and 

restart the boiler setting the fuel loading at minimum (SET-

TINGS menu - Pellets recipe). If the alarm persists, contact 

the service centre. Check if the room fan works properly (if 

present).

A04

Smoke overheating.

The set smoke threshold has been exceeded. Reduce pellets 

loading (SETTINGS menu - Pellets recipe).

A05 Pressure 

switches alarm

Smoke pressure switch intervention or water pres-

sure insufficient.

Verify chimney obstruction / door opening or hydraulic 

system pressure.

A08

Abnormal smoke fan operation.

If the alarm persists, contact the service centre.

A09

Smoke probe faulty.

If the alarm persists, contact the service centre.

A19

Water probe faulty.

Water probe disconnected / interrupted / defective / not 

recognised.

A20

Puffer probe alarm.

Puffer probe disconnected / interrupted / defective / not 

recognised.

A21

Triac alarm

The triac of the electronic card has stalled. Replace the card.

SERVICE

Routine maintenance alert (it does not block the 

system).

When this flashing message appears upon start-up, it 

means that the preset operating hours have elapsed before 

maintenance. Contact the service centre.

10.15  ALARM RESET

NEVER open the stove door while it is starting up initially or switching off, as the pellets are 

still burning at this point and there may be volatile substances.

ATTENTION!

If smoke flows into the room from the appliance or the flue during operation or initial igni-

tion, switch off the device, air out the room, and immediately contact the installation/custo-

mer service technician.

To reset the alarm, you must hold down key 1 (ESC) for a few seconds. The stove performs a check to determine whether what 

caused the alarm is still present.

Summary of Contents for TESIS 16 AIRTIGHT T2

Page 1: ...EN USER MANUAL PELLETTHERMOSTOVE OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new RIVERIDRO 16T2 23T2 23H2 OT2 MIRA 16T2 22T2 TESIS 16 23 AIRTIGHTT2 MAYA IDRO 16T2 24T2...

Page 2: ...18 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TECHNICIANS ONLY SEE SECTION N 21 9 FUEL 21 9 1 FUEL 21 9 2 PELLET SUPPLY 22 10 SAFETY DEVICES AND ALARMS 22 10 1 PRESSURE SWITCH 22 10 2 SMOKETEMPERATURE PR...

Page 3: ...nual is lost you can request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards must...

Page 4: ...reducing the interval between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature...

Page 5: ...d with 1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles duri...

Page 6: ...urer Whentheproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and...

Page 7: ...nt of a fault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetoth...

Page 8: ...stance Services 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed...

Page 9: ...ACCUMULATORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators...

Page 10: ...ES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE FOAM PEANUTS POLYSTYRENE PS 6 SORTED waste collect...

Page 11: ...djust the inner springing stress After 2 hours the smell of paint and smoke will disappear By using the stove the varnish inside the combustion chamber could be subjected to alterations This occurrenc...

Page 12: ...ate Timer Sleep only with the stove on Settings Info Date and time setting To set the date and time act as follows Press the menu button Select Time and Date Select by pressing menu Scroll with the ar...

Page 13: ...ect On with the keys Press menu to confirm and esc to exit c Feed screw loading Allows to fill the pellets loading system It can only be activated with the boiler switched off it displays an 180 count...

Page 14: ...utdown t function act as follows Press the menu button Scroll to Settings using the arrows Press menu to confirm Scroll to Eco shutdown t using the arrows Press menu to confirm Enter the minutes with...

Page 15: ...f 1 minute during which the panel displays the countdown seconds Pump it is activated for a fixed time of 10 seconds during which the panel displays the countdown 3 way the 3 way valve is activated fo...

Page 16: ...u to confirm and esc to exit q Technical menu To access the technical menu one must contact an assistance centre as one needs a password to enter To intervene on the technical menu act as follows Pres...

Page 17: ...or the glass tends to blackens and the burningpottobecomeencrusted cleanthestove cleanthefumeconduitandthechimneyflue ATTENTION Makesurepelletsandashhavenotaccumulatedinthebrazierduetofailedignition...

Page 18: ...scroll toTIMER with the arrows press the Menu key the system proposes P1 Press the keys for the subsequent timers P2 P3 P4 P5 P6 to activate P1 press the Menu key press and select ON confirm with the...

Page 19: ...all devices present are satisfied the ECO shutdown t time decrease starts by default 10 minutes it can be changed within the Settings menu During this stage the panel displays ON with a small flame a...

Page 20: ...eposits forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes The values available are from 27 to 27 with variations of 3 points at a time The va...

Page 21: ...oduct liability 9 2 PELLET SUPPLY Fig 13 Wrongopeningofthepelletsbag Fig 14 Rightopeningofthepelletsbag It is necessary to avoid to fill the hopper with the pellet when the stove is running Do not get...

Page 22: ...wer cut that lasts over 10 with the boiler on or in the start up stage when the boiler is powered again it goes back to the previous operating condition with the following procedure 1 It performs a co...

Page 23: ...ermostat alarms The temperature of the pellets hopper or the water temperature exceed the envisioned safety threshold Wait for the cooling stage to end cancel the alarm and restart the boiler setting...

Page 24: ...e After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had been using continuously and intensely the whole system chimney included...

Page 25: ...er we recommend removing part C near the brazier and using a vacuum cleaner nozzle to remove any ash build up Fig 18 Drawerremoval Fig 19 Brazierremoval 11 5 ASH DRAWER CLEANING MAYA Lift part C from...

Page 26: ...utorizedtechnicianin order to guarantee the good running of the stove Useexclusivelyoriginalspareparts 11 11 GLASS CLEANING The glass ceramic of the fire door is able to stand till 700 C but not to th...

Page 27: ...falls into the lower area around the brazier Use a vacuum cleaner to remove all the fallen material Fig 23 Pipeunitcleaning 11 14 SHUTDOWN END OF SEASON At the end of each season before switching the...

Page 28: ...an check the inner electri cal mechanicalcomponents PARTS FREQUENCY 2 3 DAYS 7 DAYS 1YEAR UNDERTHE USER S RESPONSIBILITY Brazier Ash pan Glass Lower compartment Turbulators BYTHE QUALIFIEDTECHNICIAN C...

Page 29: ...connected Burned protection fuse in the electric socket Replace the protection fuses in the electric socket 3 15A 250V Faulty control display Replace the control display Faulty flat cable Replace the...

Page 30: ...the stove burning pot obstructed holes with too ash remains Have the fan blades and auger cleaned see SMOKE RPMVARIATION User Manual Obstructed exhaust The exhaust chimney is partially or totally obs...

Page 31: ...block the system When this flashing message appears upon start up it means that the preset operating hours have elapsed before maintenance Contact the service centre 12 2 PROBLEM SOLVING THERMOSTOVE P...

Page 32: ...OSURE of the PIPE FITTINGS Radiators cold in the winter Room thermostat local or remote adjusted too low If remote thermostat check whether it is defective Adjust it to a higher temperature Replace it...

Page 33: ...O2 150 mg Nm3 NOx al 13 O2 94 mg Nm3 Heat output Nominal heat output Pnom 16 kW Minimum heat output indicative Pmin 4 9 kW Useful efficiency NCV as received Useful efficiency at nominal heat output t...

Page 34: ...l 13 O2 150 mg Nm3 NOx al 13 O2 94 mg Nm3 Heat output Nominal heat output Pnom 22 4 kW Minimum heat output indicative Pmin 4 9 kW Useful efficiency NCV as received Useful efficiency at nominal heat ou...

Page 35: ...2 94 mg Nm3 Heat output Nominal heat output Pnom 22 4 kW Minimum heat output indicative Pmin 4 9 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 92 Useful efficien...

Page 36: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...

Reviews: