
27
WALL - SMALL - STYLE
EN
•
Check the type of glitch as
.
•
Unscrew the black cap, press the button and screw the cap again.
•
Clean the burning pot and start the stove up again with P4 key.
13.9
"FAILURE DEPRESS" ALARM
To the boiler is connected a pressostat which control the depression and in some stove models on the fire door
id installed a microswitch which registers the opening.
"ACTIVE ALARM" "AL 8 - FAILURE DEPRESS": the pressostat and/or fire door which is not correctly closed stops the
power supply to the auger.
•
Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".
•
Check the type of glitch as
.
•
Unscrew the black cap, press the button and screw the cap again.
•
Clean the burning pot and start the stove up again with P4 key.
14
MAINTEINANCE
14.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
•
Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and
checked by an authorized technician in compliance with local regulations, with the instructions of the
manufacturer and those of your insurance company.
•
If there are no local regulations and no instruction from your insurance company, it is necessary to have your
fume pipe, chimney flue and chimney pot cleaned at least once a year.
•
It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and
the electronical elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance
Service.
•
After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
•
If the stove had been using continuously and intensely, the whole system (chimney included), must be
cleaned and checked more frequently.
•
In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
14.2
BURNING POT AND ASH TRAY CLEANING
The burning pot and ash tray cleaning must be executed at least every 2 days.
•
Open the door.
Fig. 35 - Burning pot extraction
Fig. 36 - Burning pot cleaning
•
) from its seat and empty it from the ash.
•
If becessary clean with a pointed object the holes obstructed by encrustations (see
).