KEUKENKACHEL OP HOUT 

NL

14.2 

KENMERKEN

BESCHRIJVING

MINI

GHIBLI

JOLLY 

OPALE 60 

COUNTRY

RUBINO

CLUB 80

OPALE 80

BREEDTE

45 cm

60 cm

60 cm

69 cm

80 cm

80 cm

DIEPTE

60 cm

60 cm

60 cm

56 cm

60 cm

60 cm

HOOGTE

85 cm

85 cm

85 cm

85 cm

85 cm

85 cm

GEWICHT

81 kg

82 kg

109-113 kg

113 kg

122 kg

130 kg

NOMINAAL THERMISCH VERMOGEN 

(Max)

5,5 kW

6,5 kW

6,4 kW

6,4 kW

6 kW

6 kW

EFFICIËNTIE (Max)

71%

77,5%

71,9%

71,9%

71,5%

71,5%

TEMPERATUUR ROOKGASSEN (Max)

346 °C

300 °C

274 °C

274 °C

187 °C

187 °C

MAXIMUM DEBIET VAN DE 

ROOKGASSEN (Max)

7,1 g/s

6,4 g/s

7,9 g/s

7,9 g/s

12,9 g/s

12,9 g/s

CO-EMISSIES (13% O

2

) (Max)

0,18%

0,37%

0,44%

0,44%

0,43%

0,43%

ONDERDRUK SCHOORSTEEN (Max)

11 Pa

12 Pa

12 Pa

12 Pa

11 Pa

11 Pa

DIAMETER AFVOERPIJP ROOKGASSEN

12 cm

12 cm

12 cm

12 cm

12 cm

12 cm

DAMPER VERPLICHTE

JA

JA

JA

JA

JA

JA

BRANDSTOF

Hout

Hout

Hout

Hout

Hout

Hout

VOCHTIGHEID VAN HOUT

< 12%

< 12%

< 12%

< 12%

< 12%

< 12%

VERWARMBAAR VOLUME 18/20°C 

Coëff. 0,045 kW (Max)

132 m

3

156 m

3

154 m

3

154 m

3

144 m

3

144 m

3

VOLUME VUURHAARD

15,5 dm

3

21 dm

3

15,5 dm

3

15,5 dm

3

18,5 dm

3

18,5 dm

3

OPENING VUURHAARD

2,5 dm

2

2,3 dm

2

2,3 dm

2

2,3 dm

2

2,4 dm

2

2,4 dm

2

AFMETINGEN OPENING VUURHAARD 

(LxH)

17,8x14 cm 18x13 cm

16x14,5 cm 16x14,5 cm 18x13,5 cm 18x13,5 cm

AFMETINGEN OVEN (LxPxH)

-

-

24,5x38,5x22 

cm

24,5x38,5x22 

cm

29,5x38,5x22 

cm

29,5x38,5x22 

cm

INHOUD ASLADE

4 dm

3

4 dm

3

4 dm

3

4 dm

3

4 dm

3

4 dm

3

ROOSTERSCHUDDER VUURHAARD

NEE

NEE

NEE

NEE

NEE

NEE

REGELBARE PRIMAIRE LUCHT

JA

JA

JA

JA

JA

JA

VASTE SECUNDAIRE LUCHT

JA

JA

JA

JA

JA

JA

VENTILATIE

JA

JA

JA

NEE

JA

NEE

VOEDING

230 V - 50 

Hz

230 V - 50 

Hz

230 V - 50 

Hz

-

230 V - 50 

Hz

-

GEABSORBEERD VERMOGEN (Max)

60 W

18 W

60 W

-

60 W

-

MINIMUM BUITENLUCHTINLAAT (laatste 

nuttige doorsnede)

100 cm

2

100 cm

2

100 cm

2

100 cm

2

100 cm

2

100 cm

2

Summary of Contents for MINI

Page 1: ...iservati en WOOD COOKING STOVE installation use and maintenance manual nl HOUTKEUKEN handleiding voor installatie gebruik en onderhoud diamante smart maxi master gemma tilde vesta taurus mini smart mi...

Page 2: ...RIC CONNECTION 15 11 USE 15 11 1 ATTENTION 15 11 2 INTRODUCTION 16 11 3 IGNITION 16 11 4 STOVE REFILLING 17 11 5 BAKING 17 11 6 HOODED TOP 17 11 7 VENTILATION 17 11 8 ADVERSE WEATHER CONDITIONS 18 11...

Page 3: ...y to your local Technical Assistance Service In Italy biomass system installation below 35 kW must comply with MD 37 08 Every qualified installer who own these requirements has to issue the certificat...

Page 4: ...t in the loss of the warranty Also excluded from this guarantee are Parts subject to normal wear such as gaskets glass claddings and cast iron grids painted chrome plated or gilded parts handles and e...

Page 5: ...the constructor instructions if the stove is made up of ceramic stone glass or any particularly fragile material components all must be moved with the utmost care 8 CHIMNEY FLUE 8 1 INTRODUCTION This...

Page 6: ...ce with current regulations The flue system must be placed on the roof The chimney flue must be provided CE in accordance with EN 1443 regulation Please find attached an example of label Fig 2 Example...

Page 7: ...les laying nearby see TECHNICAL FEATURES apage 5 8 7 CHIMNEY COMPONENTS Fig 4 Chimney components LEGEND Fig 4 page 7 1 Chimney pot 2 Fume outlet 3 Chimney flue 4 Termal insulation 5 External wall 6 Ch...

Page 8: ...o favor the draught and to avoid condensation in the pipes The fume conduit should be equivalent or longer than the outlet joint ones Some stove models are endowed with a lateral and or back exhaust C...

Page 9: ...t 5 Damper Chimney flue installation 150 mm with an enlarged drilling for pipe transit Fig 7 Example 2 LEGEND Fig 7 page 9 1 Insulating material 2 Inspection plug 3 Chimney inspection entrance 4 Minim...

Page 10: ...wall EN 13501 EN 13063 EN 1856 EN 1806 EN 15827 9 FUEL 9 1 FUEL The allowed fuel is firewood and its derivatives lignite blocks compressed sawdust etc with a maximum water content of 20 To obtain goo...

Page 11: ...bable presence of other stoves or appliances which could depress the room see EXTERNAL AIR INLET apage 7 Check at switched on stove if there is the presence of CO in the room Check if the chimney has...

Page 12: ...m 19 cm 12 cm 74 cm YES YES YES RUBINO 69 cm 85 cm 56 cm 34 5 cm 20 cm 15 cm 17 cm 74 cm YES YES YES CLUB 80 cm 85 cm 60 cm 40 cm 15 5 cm 19 cm 13 cm 74 cm YES YES YES OPALE 80 80 cm 85 cm 60 cm 40 cm...

Page 13: ...24 cm 100 cm 30 cm 50 cm RUBINO 20 cm 24 cm 100 cm 30 cm 50 cm CLUB 20 cm 20 cm 100 cm 30 cm 50 cm OPALE 60 20 cm 20 cm 100 cm 30 cm 50 cm DIAMANTE 20 cm 20 cm 100 cm 30 cm 50 cm SMART 20 cm 20 cm 100...

Page 14: ...ust be detached from possible walls and or pieces of furniture with a minimum air flow at the sides and at the back in order to allow an appliance cooling and a good distribution of heat in the enviro...

Page 15: ...connection occurs through a cable with plug put in an electric socket which is able to support charge and tension specific of every model as described in the technical datas table The plug must be eas...

Page 16: ...isable to ventilate the room because they can be noxious to people and animals If inside the combustion chamber there are booklets manuals etc remove them Check that the plug is inserted in the power...

Page 17: ...ows close the primary air valve open the fire door slowly shake the ash with the appropriate instrument insert wood in the hearth close the door and adjust again the primary air valve 11 5 BAKING When...

Page 18: ...rafs Fume outlet pipes fume conduit chimney flue chimney pot must always be cleaned scrubbed and checked by an authorized technician in compliance with local regulations with the instructions of the m...

Page 19: ...inevitably present crazings seedinesses shadings To clean ceramic panels use a soft and dry cloth If using any cleaners this will seep through the crazings putting them in evidence 12 7 GLASS CLEANIN...

Page 20: ...For models with ventilation clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise As this operation is so delicate it must therefore be executed by...

Page 21: ...ight In case of break proceed as follow Remove the plug from the socket Unbolt the glass protection Remove the lamp and replace it with another with the same features 15W 240V 300 C Reassemble all Onc...

Page 22: ...blem persists contact and expert stove repairer who will check the chimney flue efficiency Ambient without air recycling Create immediately a ventilation grid Creation of condensation Large chimney fl...

Page 23: ...l seasoned wood Too slow combustion Open air registers in order to increase the fire and fume output temperature Bad quality fuel Use fuel described in FUEL apage 10 Cooker overheating Too much wood i...

Page 24: ...ER REQUIRED YES YES YES YES YES YES FUEL Wood Wood Wood Wood Wood Wood WOOD HUMIDITY 12 12 12 12 12 12 HEATING VOLUME 18 20 C Coeff 0 045 kW Max 132 m3 156 m3 154 m3 154 m3 144 m3 144 m3 BURNING POT V...

Page 25: ...12 cm DAMPER REQUIRED YES YES YES YES YES YES FUEL Wood Wood Wood Wood Wood Wood WOOD HUMIDITY 12 12 12 12 12 12 HEATING VOLUME 18 20 C Coeff 0 045 kW Max 144 m3 144 m3 199 m3 144 m3 144 m3 154 m3 BUR...

Page 26: ...NSLUITING 39 11 GEBRUIK 40 11 1 LET OP 40 11 2 INLEIDING 40 11 3 STARTEN 40 11 4 DE KACHEL VULLEN 41 11 5 GEBRUIK VAN DE OVEN 41 11 6 DEKSEL 42 11 7 VENTILATIE 42 11 8 ONGUNSTIGE WEERSOMSTANDIGHEDEN 4...

Page 27: ...s dit van eigenaar verandert Bent u de handleiding kwijtgeraakt vraag dan een kopie aan bij de technische assistentiedienst bij u in de buurt In Itali wordt voor de installatie van systemen met een bi...

Page 28: ...et water onjuist uitgevoerde aanslagwerende behandelingen watertekort bezinksel van modder of kalkaanslag Ineffici ntie van de schoorstenen rookgaskanalen of delen van de installatie waarvan het toest...

Page 29: ...AN DE KACHEL Zowel voor de verpakte als voor de uitgepakte kachel is het noodzakelijk de volgende instructies voor de verplaatsing en het transport van de kachel zelf in acht te nemen vanaf het moment...

Page 30: ...stalleerd is of op zijn minst in de aangrenzende ruimte Onder de opening moet een opvangruimte voor vast materiaal en condens aanwezig zijn die via het metalen hermetisch gesloten deurtje toegankelij...

Page 31: ...en De schoorsteenpot heeft een belangrijke functie voor de goede werking van de verwarmingsapparatuur Er wordt geadviseerd een windbestendige schoorsteenpot te gebruiken zie Fig 3 op pag 31 De zone va...

Page 32: ...jk te laten nakijken wanneer alle apparatuur ingeschakeld is of de drukval tussen het vertrek en de buitenlucht niet groter is dan 4 0 Pa vergroot de opening van de luchtinlaat zo nodig EN 13384 De lu...

Page 33: ...te pakking gesloten worden Het is verboden meer apparaten op hetzelfde rookkanaal aan te sluiiten Het is verboden om de rookafvoer van zich erboven bevindende afzuigkappen in hetzelfde rookkanaal te v...

Page 34: ...ikje voor de reiniging van de schoorsteen Fig 8 Voorbeeld 3 LEGENDA Fig 8 op pag 34 1 Isolatie 2 Inspectiedop 3 Minimum veiligheidsafstand 0 5 m 4 Damper Extern rookkanaal dat tot stand gebracht is me...

Page 35: ...KWALITEIT RENDEMENT Eik Uitstekend 100 Haagbeuk Uitstekend 100 Es Heel goed 92 Esdoorn Heel goed 91 Berk Goed 89 Iep Goed 84 Beuk Goed 80 Wilg Voldoende 71 Spar Voldoende 70 Noorse den Slecht 67 Larik...

Page 36: ...t dit het risico op brandwonden en korsluiting kan veroorzaken Om meer apparaten te kunnen installeren moet de buitenluchtinlaat de daarvoor geschikte afmetingen krijgen zie BUITENLUCHTINLAAT op pag 3...

Page 37: ...77 cm NEE JA JA GEMMA 87 cm 86 cm 58 cm 43 5 cm 18 cm 28 5 cm 77 cm NEE JA JA TILDE 85 cm 83 cm 61 cm 42 5 cm 19 cm NEE JA NEE VESTA 83 cm 90 cm 58 cm 16 5 cm 18 cm JA NEE NEE TAURUS 83 cm 90 cm 58 cm...

Page 38: ...el kan gekozen worden voor een alleenstaande installatie tegen een muur of tussen twee muren De wanden van de belendende meubels en de achterwand van de kachel moeten van hittebestendig 200 C en brand...

Page 39: ...uten weer vast Let op de inbouwmodellen op marmeren blad Als de kachel uit de meubels gehaald moet worden verlaag de voetjes tot het fornuis onder het niveau van het marmeren blad komt en verwijder he...

Page 40: ...staande aanwijzingen opgevolgd worden Het hout kan heel makkelijk aangestoken worden wanneer de installatie correct verlopen is en het rookgaskanaal doeltreffend is Bij de eerste inschakeling van de k...

Page 41: ...erne temperatuur van de vuurhaard wanneer de vlam hoog is gaat de klep dicht zodat minder lucht stroomt Eens de vlam brandt wordt aangeraden de klep in stand te houden op Als de rookgassen met moeite...

Page 42: ...iet correct afgevoerd worden Doe weinig hout in de vuurhaard en houd de luchtregelkleppen maximaal open 11 9 GEVAAR CREOSOOT Het gebruik van vochtig hout en of hout van slechte kwaliteit vb harshouden...

Page 43: ...he afval Maak ook de asruimte vrij 12 3 JAARLIJKSE REINIGING VAN DE ROOKGASSENLEIDINGEN Reinig deze jaarlijks en verwijder het roet met gebruik van borstels De reiniging moet door een kachel en schoor...

Page 44: ...waarna het oppervlak geolied wordt met vaselineolie 12 10 REINIGING BINNENKANT OVEN Jaarlijks en indien nodig maandelijks moet de binnenkant van de oven gereinigd worden door de verbrandingsresten aa...

Page 45: ...te werk gaan Haal de stekker uit het stopcontact Maak de bevestigingen los van de schakelaar zie Fig 13 op pag 40 en herhaal na hem vervangen te hebben de handeling in omgekeerde volgorde 12 14 VERVAN...

Page 46: ...verbrandingslucht De beschadigde onderdelen moeten onmiddellijk vervangen worden om verdere schade aan de kachel te voorkomen Fig 18 Schroef het profiel los Fig 19 Verwijder het profiel Fig 20 Verwijd...

Page 47: ...specialiseerd technicus die de effici ntie van het rookgaskanaal nagaat Geen verluchting in het vertrek Zorg onmiddellijk voor een verluchtingsrooster Condensvorming Te grote doorsnede van het rookgas...

Page 48: ...e verbranding Open de luchtkleppen om het vuur aan te wakkeren en de temperatuur van de uitgaande rookgassen op te drijven De brandstof is van heel slechte kwaliteit Gebruik de brandstof beschreven in...

Page 49: ...m DAMPER VERPLICHTE JA JA JA JA JA JA BRANDSTOF Hout Hout Hout Hout Hout Hout VOCHTIGHEID VAN HOUT 12 12 12 12 12 12 VERWARMBAAR VOLUME 18 20 C Co ff 0 045 kW Max 132 m3 156 m3 154 m3 154 m3 144 m3 14...

Page 50: ...cm 12 cm DAMPER VERPLICHTE JA JA JA JA JA JA BRANDSTOF Hout Hout Hout Hout Hout Hout VOCHTIGHEID VAN HOUT 12 12 12 12 12 12 VERWARMBAAR VOLUME 18 20 C Co ff 0 045 kW Max 144 m3 144 m3 199 m3 144 m3 14...

Page 51: ...NOTE...

Page 52: ...a Lucia di Piave TV ITALY tel 39 0438 738669 fax 39 0438 73343 www cadelsrl com Partner of pellet stoves wood stoves wood cooking stoves thermostoves pellet fireplace inserts pelletkachels houtkachels...

Reviews: