If the floor is made of wood, it is recommended to place a floor protection in accordance
with the Standards in force in the country of installation.
Fig. 2 - Distances to follow
TYPE
NON-FLAMMABLE WALLS
FLAMMABLE WALLS
AQUOS 15-22-22 H2O
A = 5 cm / B = 5 cm
A = 10 cm / B = 10 cm
IBIS 11-15-22-22 H2O
A = 5 cm / B = 5 cm
A = 10 cm / B = 10 cm
IDRON 11-15-22-22 H2O
A = 5 cm / B = 5 cm
A = 10 cm / B = 10 cm
5.5
CONNECTION OF THE FUME EXHAUST PIPE
When making the hole for the passage of the smoke discharge pipe, one must take into account the possible
presence of flammable materials. If the hole must be made through a wooden wall or thermolabile material,
the INSTALLER MUST first of all use the appropriate wall fitting (minimum diameter 13 cm) and suitably insulate the
pipe of the product that passes through it using adequate insulating materials (1.3 - 5 cm thick with minimum
thermal conductivity 0.07 W/m°K).
The same minimum distance must be applied if the pipe of the product must pass through vertical or horizontal
sections near the thermolabile wall.
It is recommended to use an insulated double-wall pipe in external sections in order to prevent condensation
from forming.
The combustion chamber works with depression. The fume pipe for fume exhaust will be in depression when
conncted to an efficient chimney flow.
Always use pipes and fittings with appropriate seals that guarantee tightness.
It must be possible to inspect all sections of the flue duct and they must be removable for
periodic internal cleaning (T-fitting with inspection hole).
Position the product considering all the above requirements and instructions.
IMPORTANT!
All 90° angles (max. 3) in the smoke exhaust duct must be preferably fitted with the relative
T-fittings with inspection hole.
TO THE CONNECTION WITH THE CHIMNEY FLUE THERE CANNOT BE USED MORE THAN 2-3 mt
(WITH INCLINATION BELOW 3%) OF HORIZONTAL PIPE AND THERE MUST NOT BE USED MORE
THAN 3 CURVES WITH ANGLE \x3e 90°. IT IS FURTHER ADVISABLE NOT TO EXCEED THE LENGHT
OF 6 METERS WITH THE Ø 80 mm PIPE.
Summary of Contents for IDRON 22 AIRTIGHT
Page 13: ...13 AQUOS IBIS IDRON EN Fig 7 Ibis 11 dimensions ...
Page 14: ...14 AQUOS IBIS IDRON EN Fig 8 Ibis 15 Ibis 22 Ibis 22 H2O dimensions ...
Page 15: ...15 AQUOS IBIS IDRON EN Fig 9 Idron 11 dimensions ...
Page 16: ...16 AQUOS IBIS IDRON EN Fig 10 Idron 15 Idron 22 Idron 22 H2O dimensions ...
Page 36: ...36 AQUOS IBIS IDRON EN Fig 32 Configuration 3 Fig 33 Configuration 4 ...
Page 53: ...NOTE ...
Page 54: ...NOTE ...
Page 55: ...NOTE ...