• Content: 100% untreated wood with no added binding agents (max percentage of bark: 5%).
• Packaging: in bags made from environmentally friendly or biologically decomposable material.
The company strongly recommends using certified fuel for its products (DINplus, Ö-Norm
M7135 or Pellet Gold).
Poor quality pellets or others that do not comply with that specified previously compromises
the operation of your product and can therefore render the warranty and product liability
null and void.
5.2
PRECAUTIONS REGARDING INSTALLATION
IMPORTANT!
Product installation and assembly must be carried out by qualified personnel.
The product must be installed in a suitable place for it to be regularly opened and routine maintenance to be
performed.
The site must be:
• compliant for proper operation.
• Equipped with an adequate smoke expulsion system.
• Equipped with ventilation intake from outside.
• Equipped with 230V 50 Hz power supply with an EC compliant earth system.
The product must be connected to a chimney or an internal or external vertical duct that complies with the
regulations in force. The product must be positioned in such a way that the electrical socket is accessible.
IMPORTANT!
The product must be connected to a chimney or a vertical duct that can expel the smoke
at the highest point of the building.
In any case smoke derives from combustion of types of wood and if it comes in contact with
or close to walls, these can become dirty. Moreover, utmost attention is required as they are
almost invisible but very hot and can cause burns. The holes of the external air inlet and the
smoke outlet pipe must be drilled before positioning the product.
5.3
THE OPERATING ENVIRONMENT
In the case of presence of other heating appliances, appropriate air inlets must provide appropriate air flow for
the proper running of each appliance.
In case that in the place where the appliance is installed, other extraction funs (for example exhaust fans) are
present and running, disease can be caused because of the lack of combustion air.
The installation of the product is not allowed in bedrooms, bathrooms or in rooms where
it has already been installed another heating appliance without independent air inlet
(fireplace, stove, etc.).
It is forbidden to install the product in places with explosive athmosfere.
The floor where the appliance is installed must be properly dimensioned in order to bear its
weight.
The ambient ventilation can be adjusted towards the rear wall only in case of the presence
of a proper duction insulated from hot air flow.
5.4
MINIMUM DISTANCES
If the walls are not flammable place the stove at a minimum rear distance of at least 10 cm. In case of flammable
walls keep the stove at a minimum rear distance (A) of 5 cm, lateral (B) of 10 cm, minimum distance from the
pipe to the wall (E) 50 and front distance of 100 cm.
In case of presence of object considered flammable such as pieces of furniture, curtains and sofas the distance
from the stove must considerably be increased,
Summary of Contents for IDRON 22 AIRTIGHT
Page 13: ...13 AQUOS IBIS IDRON EN Fig 7 Ibis 11 dimensions ...
Page 14: ...14 AQUOS IBIS IDRON EN Fig 8 Ibis 15 Ibis 22 Ibis 22 H2O dimensions ...
Page 15: ...15 AQUOS IBIS IDRON EN Fig 9 Idron 11 dimensions ...
Page 16: ...16 AQUOS IBIS IDRON EN Fig 10 Idron 15 Idron 22 Idron 22 H2O dimensions ...
Page 36: ...36 AQUOS IBIS IDRON EN Fig 32 Configuration 3 Fig 33 Configuration 4 ...
Page 53: ...NOTE ...
Page 54: ...NOTE ...
Page 55: ...NOTE ...