background image

©2014 CADEL srl | All rights reserved – tutti i diritti riservati

en

WOOD STOVE

installation

use

 

and

 

maintenance

 

manual

carina

 - 

dora

Summary of Contents for CARINA 9,5 kW

Page 1: ... 2014 CADEL srl All rights reserved tutti i diritti riservati en WOOD STOVE installation use and maintenance manual carina dora ...

Page 2: ...CTION 13 10 2 OVERALL DIMENSIONS 14 10 3 GENERAL INSTALLATION 15 10 4 ELECTRIC CONNECTION 15 11 USE 16 11 1 ATTENTION 16 11 2 INTRODUCTION 16 11 3 IGNITION 16 11 4 STOVE REFILLING 16 11 5 VENTILATION 17 11 6 ADVERSE WEATHER CONDITIONS 17 11 7 CREOSOTE DANGER 17 11 8 FIRE EXTINGUISHING IN CASE OF FIRE 17 12 MAINTEINANCE 17 12 1 INTRODUCTION 17 12 2 BURNING POT AND ASH TRAY CLEANING 18 12 3 FUME PIP...

Page 3: ...ed in this manual to obtain the best efficiency This instruction manual is an integral part of the product make sure it is delivered with the appliance also in case of sold to others In case of loss please ask a copy to your local Technical Assistance Service All local regulations including those referring to national European standards must be respected during appliance installation In Italy biom...

Page 4: ...roper overheating of the equipment use of fuels not conforming to the types and quantities indicated in the instructions provided Further damage caused by incorrect user interventions in an attempt to fix the initial fault Worsening of the damage due to the continued use of the equipment by the user once the defect has been noticed In the presence of a boiler any corrosions incrustations or breaks...

Page 5: ...1 PACKAGING The packaging is made up of recyclable cardboard boxes according to RESY standards recyclable expanded polystyrene inserts and wooden pallets All packaging materials can be re used for a similar use or eventually discharged as waste assimilable to the municipal solid ones in accordance with current regulations After having removed the packaging please assure you about the integrity of ...

Page 6: ...he correct running of the heating appliance It is fundamental that the chimney flue is perfectly built and always maintained with a perfect efficiency The chimney flue must be sole with insulated stainless steel pipes or installed on the existing chimney flue Both this solutions must be endowed with an inspection door 8 3 TECHNICAL FEATURES Fig 1 Inclined roof LEGEND Fig 2 page 6 1 Height over the...

Page 7: ...rnt oil deposits reduce its section so blocking the draught In great quantities they can flare up The fumes extraction pipes fumes conduit chimney flue chimney pot must always be cleaned scrubbed and checked by an expert stove repairer in compliance with current regulations with the instructions of the stove manufacturer and the directives of your insurance company In case of doubts please follow ...

Page 8: ... TECHNICAL FEATURES page 6 8 7 CHIMNEY COMPONENTS Fig 4 Chimney components LEGEND Fig 5 page 8 1 Chimney pot 2 Fume outlet 3 Chimney flue 4 Termal insulation 5 External wall 6 Chimney union 7 Fume pipe 8 Heat generator 9 Inspection door 10 Damper ...

Page 9: ...birds In such a way it cannot be obstructed by any object In case of installation with sealed chamber the air inlet is not necessary 8 9 CHIMNEY FLUE CONNECTION Your stove works through a natural draught It is obligatory to check that all pipes are realized in compliance with the following regulation on material selection EN 1856 1 EN 1856 2 e UNI TS 11278 All must be effected by specialized perso...

Page 10: ...closed spaces also at open top It is forbidden to connect any other appliance wood stoves cooker hoods boilers etc The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat susceptible components The fume conduit must be connected with stove exhaust in a fixed and tight manner and if required with the insertion of a damper 8 10 EXAMPLES OF CORRECT INSTALLATION Fig 7 Ex...

Page 11: ...ance 4 Minimum safety distance 0 5 mt 5 Inclination 3 6 Level section 1 mt 7 Damper Old chimney flue with an inserted pipe of minimum Ø150 mm and with an external door which enables the chimney cleaning Fig 9 Example 3 LEGEND Fig 10 page 11 1 Insulating material 2 Inspection plug 3 Minimum safety distance 0 5 mt 4 Damper ...

Page 12: ...rewood and its derivatives lignite blocks compressed sawdust etc with a maximum water content of 20 To obtain good firewood it must be seasoned outside for at least 2 years in a place protected from the weather Using humid wood or waste bark could create condension and creosote into the ductions and in the hearth A heat yield of humid wood is great lower than dry wood Fig 10 Wood positioning To kn...

Page 13: ...s the combustible air inlet Check the probable presence of other stoves or appliances which could depress the room see EXTERNAL AIR INLET page 9 Check at switched on stove if there is the presence of CO in the room Check if the chimney has the necessary draught Check if during the fume passage all has been executed in safety probable fume losses and distances from flammable materials etc The insta...

Page 14: ...14 CARINA DORA EN 10 2 OVERALL DIMENSIONS Fig 11 Overall dimensions LEGEND Fig 12 page 14 1 52 cm 2 92 5 cm 3 45 8 cm 4 14 cm 5 26 cm 6 Exhaust fumes d 12 cm ...

Page 15: ...f there are highly flammable objects curtains fitted carpet etc all these distances must be further increased with 1 meter If the walls are made up of flammable materials check the safety distances see Fig 13 page 15 At maximum power check that the wall temperature does not ever exceed 80 C If it would be necessary please install a fire resistant plate on the concerned walls In some countries also...

Page 16: ...d ignition occurs very easily if the installation is correct and if the chimney flue is efficient By first ignition of the stove hold a slow fire for at least 4 5 hours in order to allow the material of which the heater and the hearth are made up of to adjust the inner mechanical stresses This operation must be executed at least 3 4 times a year Plant fat waste and varnishes can release bad smells...

Page 17: ... is out of order the stove can work in the same way provided that using a low flame Thus do not load the hearth with wood excessively In case that the fan is out of order contact an authorized technician who will replace it woth an original spare part 11 6 ADVERSE WEATHER CONDITIONS When the external temperatures are severe and or there are adverse weather conditions strong wind the chimney is sub...

Page 18: ...ASH TRAY CLEANING For a good combustion before of every stove ignition remove the ash which has settled in the burning pot The abundant ash obstructes the primary air flow which is fundamental for a good combustion Remove ash from the burning pot by shaking it to let it fall in the ash tray If full the sah tray must be empty Ash must be kept in a metal container with sealed cap the same container ...

Page 19: ...on the back side Unscrew the 4 screws at the sides of the casing of the fan Disconnect the faston and unscrew the failure fan screws Replace the fan and repeat the inverse operation 12 9 GASKET REPLACEMENT In case of deterioration of fire door gasket and or ash door gasket it is necessary to replace them by an autorized technician in order to guarantee the good running of the stove Use exclusively...

Page 20: ...m persists contact and expert stove repairer who will check the chimney flue efficiency Ambient without air recycling Create immediately a ventilation grid Creation of condensation Large chimney flue section Reduce the chimney flue section with thermal insulater pipes No insulated chimney flue Cover the chimney flue with insluating material Too slow combustion Open air registers in order to increa...

Page 21: ...ove repairer who will check the chimney flue efficiency Too humid wood Use well seasoned wood Too slow combustion Open air registers in order to increase the fire and fume output temperature Bad quality fuel Use fuel described in FUEL page 12 14 TECHNICAL DATAS 14 1 WIRING SCHEME For models endowed with ventilation system please follow the following wiring scheme Fig 13 Wiring scheme ...

Page 22: ...ION Max 12 Pa 12 Pa FUME OUTLET DIAMETER 12 cm 12 cm FUME OUTLET POSITION Upper Upper DAMPER REQUIRED YES YES FUEL WOOD WOOD WOOD HUMIDITY 13 13 HEATING VOLUME 18 20 C Coeff 0 045 kW Max 228 m3 228 m3 HOURLY CONSUMPTION 2 60 kg h 2 60 kg h BURNING POT VOLUME 31 7 dm3 31 7 dm3 BURNING POT OPENING 7 4 dm2 7 4 dm2 ASH TRAY CAPACITY 6 3 dm3 6 3 dm3 BURNING POT GRID SHAKER YES YES ADJUSTABLE PRIMARY AI...

Page 23: ...NOTE ...

Page 24: ...ta Lucia di Piave TV ITALY tel 39 0438 738669 fax 39 0438 73343 www cadelsrl com Partner of pellet stoves wood stoves wood cooking stoves thermostoves pellet fireplace inserts pelletkachels houtkachels houtkeukens thermokachel open haard pellets Rev 02 2013 ...

Reviews: