5
2. APPLIANCE PERFORMANCE
(1)
Fuel type
Dry cordwood
Recommended heating area
[*]
500 to 1,500 ft² (46 to 139 m²)
Firebox volume
2.3 ft³ (0.065 m³)
Maximum burn time
[*]
13 h
Maximum input capacity (dry cordwood)
(2)
198,000 BTU
Overall heat output rate (min. to max.)
(3)
11,319 BTU/h to 37,053 BTU/h (3.3 kW to 10.8 kW)
Average overall efficiency
(4)
75.7% (HHV)
(5)
81.1% (LHV)
(6)
Delivered heat output rate (min. to max.)
(7)
10,849 BTU/h to 36,429 BTU/h (3.2 kW to 10.7 kW)
Average delivered efficiency
(8)
70.6% (HHV)
(5)
77.2% (LHV)
(6)
Optimum efficiency
(9)
85.1%
Average particulate emissions rate
(10)(11)
0.841 lb/mmBTU (0.362 g/MJ)
Average CO
(12)
15.61 lb/mmBTU (6.72 g/MJ)
Average electrical power consumption
(13)
760 Wh
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors,
climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its
capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat
distribution systems have a significant impact in making heat circulation optimum.
(1)
Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time
and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with moisture
content between 18% and 28%.
(2)
Input value at 10lb/ft³ fuel loading density and dry energy value of 8,600BTU/lb.
(3)
Overall: Radiated and delivered heat together at10lb/ft³ fuel loading density over one total burn cycle.
(4)
Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(5)
Higher Heating Value of the fuel.
(6)
Lower Heating Value of the fuel.
(7)
Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.
(8)
Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(9)
Optimum overall efficiency at a specific burn rate (LHV).
(10)
Based on delivered heat output.
(11)
This appliance is officially tested and certified by an independent agency.
(12)
Carbon Monoxyde. Based on overall heat output at 10lb/ft³ fuel loading density.
(13)
Unless st
ated otherwise, measures were taken directly at the main power source and include all electrical components present in
the appliance.
Summary of Contents for PF01302
Page 8: ...8 6 2 COMBINED WOOD ELECTRIC ...
Page 45: ...45 15 GENERAL ELECTRICAL DIAGRAM ...
Page 46: ...46 16 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Page 47: ...47 17 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Page 49: ...49 18 4 AIR CONDITIONNING DAMPER 18 5 HUMIDIFIER 18 6 HEAT PUMP ...
Page 50: ...50 19 EXPLODED VIEW AND PART LIST ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 ...