KSACN0101CAC

KSACN0101AAA

Installation Instructions

Wired Controller

for Ductless Split Systems

Read and become familiar with these instructions before beginning
installation.

SAFETY CONSIDERATIONS

Read these instructions thoroughly and follow all warnings or
cautions included in the literature and attached to the unit.

Consult local building codes and National Electrical Code (NEC)

for special requirements. Recognize safety information.
This is the safety- alert symbol

!

!

. When you see this symbol on

the unit and in instructions or manuals, be alert to the potential for

personal injury. Understand these signal words: DANGER,
WARNING, and CAUTION. These words are used with the

safety- alert symbol. DANGER identifies the most serious hazards
which

will

result in severe personal injury or death. WARNING

signifies hazards which

could

result in personal injury or death.

CAUTION is used to identify unsafe practices which

may

result

in minor personal injury or product and property damage. NOTE

is used to highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or

death.
Before beginning any modification or installation of this kit, be

sure the main electrical disconnect is in the OFF position.

Ensure power is disconnected to the fan coil unit. On some

systems both the fan coil and the outdoor unit may be on the

same disconnect. Tag the disconnect switch with a suitable

warning label. There may be more than one disconnect.

!

WARNING

EQUIPMENT DAMAGE HAZARD

Failure to follow this warning may result in equipment

damage.
Do not install the wired controller in an area subjected to

excessive steam, oil or sulfide gas. Doing so may cause the

controller to deform and/or fail.

!

CAUTION

INSTALLATION

Entrust the distributor or authorized professionals to install the

unit. Installation by unskilled persons may lead to improper

installation, electric shock, or fire. Re- installation must be

performed by authorized professionals. Non- compliance may

lead to electric shock or fire.

!

WARNING

Kit Contents: Confirm the following parts are included

No.

Description

Qty

Remarks

1

Wired controller

1

n/a

2

Installation and Owner’s

Manual

1

n/a

3

Screws

3

M4X20 (For mount-

ing on the wall)

4

Wall plugs

3

For wall mounting

5

Screws

2

M4X25 (For mount-
ing on switch box)

6

Plastic screw bars

2

For fixing on switch

box

7

The connective wires

group

1

24AWG

Field Supplied Components: Prepare the following assemblies

on site

No.

Description

Qty

Type

Remarks

1

Switch Box

1

n/a

n/a

2

Wiring Tube

(insulating sleeve and

tightening screw)

1

n/a

n/a

TABLE OF CONTENTS

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . .

INSTALLATION ACCESSORY

2

. . . . . . . . . . . . . . . . . . .

INSTALLATION METHOD

2

. . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for KSACN0101CAC

Page 1: ...main electrical disconnect is in the OFF position Ensure power is disconnected to the fan coil unit On some systems both the fan coil and the outdoor unit may be on the same disconnect Tag the disconnect switch with a suitable warning label There may be more than one disconnect WARNING EQUIPMENT DAMAGE HAZARD Failure to follow this warning may result in equipment damage Do not install the wired co...

Page 2: ...ns the installation method for the wired controller Refer to the wiring diagram in this manual to connect the wired controller to the indoor unit S The wired controller operates in a low voltage loop circuit Do not connect the 208 230V power directly to the thermostat Do not wire this type of wire in the same loop The wiring clearance between the configured tubes should maintain a range of 12 20 i...

Page 3: ...ale joint of the wires group from the main board to the male joint of the connective wires group S Connect the other side of the connective wires group with the male joint of the wires group leads from the wired controller S Remove the upper part of the wired controller ...

Page 4: ...he wired controller Fig 4 wired controller The PCB is mounted in the upper part of the wired controller Be careful not to damage the board with the slot screwdriver WARNING S Fasten the back plate of the wired controller S For exposed mounting fasten the back plate on the wall with the 3 screws M4x20 and plugs Fig 5 Back plate ...

Page 5: ...he switch box with 2 screws M4x25 and then fasten it to the wall with 1 screw M4x20 Fig 6 Switch box NOTE Place on a flat surface Be careful not to distort the back plate of the wired controller by over tightening the mounting screws Fig 7 Wire outlet ...

Page 6: ...ller use a trap and putty to seal the wire connectors during wiring installation During installation reserve a certain length of the connecting wire to make removing the wired remote controller easier during maintenance WARNING S Reattach the upper part of the wired controller S After adjusting the upper case buckle the upper case Avoid clamping the wiring during installation ...

Page 7: ...Your wired controller may differ slightly Copyright 2015 CAC BDP S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No KSACN0101 01SI Replaces NEW Edition Date 02 15 ...

Reviews: