CAC / BDP 38GRQ Owner'S Manual Download Page 1

40GRQ / 619FB / 38GRQ / 538FR

High- Wall Ductless Split System

Sizes 09 - 18

Owner’s Manual

TABLE OF CONTENTS

PAGE

SAFETY PRECAUTIONS

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GENERAL

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INDOOR UNIT PART NAMES

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REMOTE CONTROL PART NAMES

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DISPLAY PANELS

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REMOTE CONTROL

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REMOTE CONTROL FUNCTIONS

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CLEANING, MAINTENANCE AND TROUBLESHOOTING

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NOTE TO EQUIPMENT OWNER:

Please read this Owner’s Information Manual carefully before installing and using this appliance

and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the

spaces provided. This information, along with the installation data and dealer contact information,

will be helpful should your system require maintenance or service.

UNIT INFORMATION

Model # ___________________________________
Serial # ___________________________________

INSTALLATION INFORMATION

Date Installed _____________________________

DEALERSHIP CONTACT INFORMATION

Company Name: _________________________________
Address:_________________________________________
________________________________________________
Phone Number:__________________________________
Technician Name:_________________________________
________________________________________________

Summary of Contents for 38GRQ

Page 1: ...nd serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ___________________________________ Serial ___________________________________ INSTALLATION INFORMATION Date Installed _____________________________ DEALERSHIP CONTACT...

Page 2: ...ries when modifying this product WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only using approved tubing and...

Page 3: ...inHose 7 Refrigerant Lines Outdoor unit 4 Air outlet Air inlet Air inlet Air outlet 3 1 2 5 6 7 Fig 1 Indoor Outdoor Unit DISPLAY PANELS NOTE The display panel on the indoor unit can be turned on or off using the LIGHT button on the remote control The temperature readout will be replaced by an error code if there is a malfunction ...

Page 4: ...ton 4 Heat button 6 I Feel button 7 Up down swing button 9 Left right swing button 14 Temp button 15 Sleep button Light button 16 17 Wifi button 11 Clock button 12 13 X Fan button 10 T ON T OFF button 8 Mode button 5 Fan button Blank Fig 2 Remote Control Remote Control Display Fig 3 Remote Control Display ...

Page 5: ...o 6 feet from the indoor high wall unit 3 Point the remote controller at the indoor wall unit and press the Blank button for 3 seconds 4 The indoor high wall unit provides 3 beeps to signal a successful match 5 Press the Power ON button on the remote controller The green indicator light displays on the indoor high wall unit 6 The remote controller is matched and ready for use If the indoor unit an...

Page 6: ...arge directions including Continuous Sweep The Horizontal Swing Louver icon appears Press this button to set swing angle which changes in direction as shown in the following figure no display stops at current position Fig 9 Horizontal Swing Louver Angles I FEEL Press this button to use the I FEEL function and the icon appears The unit senses room temperature at the remote controller instead of at ...

Page 7: ...ons to cancel the Sleep 3 Mode NOTE During this procedure if no button is pressed within 10 seconds the remote controller automatically exits the sleep curve setting and resumes the original display If the ON OFF MODE TIMER SLEEP COOLING or HEATING button is pressed during the setting or inquiry procedure the remote controller exits the sleep curve setting SIESTA MODE 4 In Siesta Mode the unit aut...

Page 8: ...tion may result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If necessary a mild liquid detergent can be applied a...

Page 9: ...sert plug Restart unit Water leaks into room from Indoor unit Condensing water has overflowed Check indoor condensing drain or call your representative Unit System Does Not Work To protect the unit upon an immediate restart after a stop the system controller delays the unit for 3 minutes before allowing the unit to start back up The circuit breaker has tripped or a fuse has blown Power failure Err...

Page 10: ...S 7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No OM38 40GR 03 Replaces OM38 40GR 02 Edition Date 06 15 ...

Reviews: