STS-5SU Internal Stacker Unit

Introduction

The SmartStack STS-5SU Internal Stacker Unit is a 4-port 
interface module that is installed into the rear slot of any 
SmartStack Token Ring Switch. When five SmartStack 
switches are connected together through the SmartStack STS-
5SU module, the switches combine to form one logical switch. 
The SmartStack STS-5SU front panel is shown in Figure 1.

Figure 1.  SmartStack STS-5SU Front Panel

SmartStack STS-5SU Package Contents

The SmartStack STS-5SU package contains the following 
items:

One SmartStack STS-5SU Internal Stacker Unit for the 
Cabletron SmartStack Token Ring Switch

One SmartStack STS-5SU Installation Guide (this 
document)

Installation

Use the following steps when installing the SmartStack STS-
5SU module in the SmartStack switch.

Note: SmartStack STS-5SU modules are not hot-swappable. 
Always be sure that the power is off before installing or 
removing a module. If the power is on, damage to the 
equipment may result. Once the module is installed in the 
switch, external cables may be connected or removed without 
having to remove power from the switch.

1. Disconnect power to the switch.

2. If a blank cover is over the stacker slot on the back panel, 

remove it by unscrewing the two attachment screws.

3. To prevent possible static damage to the module, hold it by 

its edges only. Be careful not to touch the top or bottom.

4. Slide the module into the slot evenly, taking care to line up 

the edges with the guides.

5. Seat the module by pressing the front of the module with 

your thumbs.

6. Secure the module to the chassis by tightening the thumb 

(panel) screws at the left and right edges of the front panel. 
Do not overtighten the screws.

7. Return power to the switch.

SmartStack STS-5SU Connectors and LEDs

The following tables describe the connectors and LEDs on the 
SmartStack STS-5SU front panel.

Connecting the Stacker Link Cable

A proprietary 50-pin cable must be used to connect ports on 
the SmartStack STS-5SU module with up to four SmartStack 
STS-LM Link Modules in other SmartStack switches. Five 
switches can be combined in this way to form a very cost-
effective stack of switches.

Note: The SmartStack STS-5SU Internal Stacker Unit must 
only be connected to SmartStack STS-LM Link Modules. You 
cannot create a stack by connecting SmartStack STS-5SU 
modules together.

When inserting the cable connector, keep the connector 
straight to minimize the risk of bent or damaged pins.

Working With a Stack

When the SmartStack switch powers up, it runs through a 
series of diagnostics. Immediately after the diagnostics are 
complete, the SmartStack switch enters the stack discovery 
mode. The discovery mode is used to sense if the unit is cabled 
to other units. If the SmartStack switch through a SmartStack 
STS-5SU is connected to other units during the discovery 
mode, the switches automatically combine to form a stack.

Each unit is assigned a box number. The switch with the lower 
MAC address becomes Box 1, the switch with the higher 
MAC address becomes Box 2 and so forth. When accessing 
switch specific settings from a management console, you will 
be prompted for a box number.

The switches in the stack combine certain configuration 
parameters so that the stack as a unit uses one set of 
parameters. These parameters are discussed below in “Inter-
Box Parameters”.

The stack can now be managed as a single entity from a 
management console or management application.

Inter-Box Parameters

The SmartStack switches participating in the stack must 
combine configuration information so that the stack as a whole 
uses common parameters. One of the participating switches 
becomes the provider of inter-box parameters.

If the switches have the same configuration information, the 
switch that becomes Box 1 becomes the provider. If the 
configuration information is different, a split-stack will be 
formed and a warning message will be displayed on the 
console screen. You will be requested to briefly press the 
SysReq button on the switch that is to be the provider of inter-
box parameters. When you have selected the provider, the 
other switch will replace its stack related configuration 
parameters with those of the provider.

Table 3 lists the inter-box parameters.

Connector

Description

P2–P5

50-pin SCSI-2 connector for proprietary 
Stacker Link cable.

Table 1.  SmartStack STS-5SU Network Connector

LED

State

Description

P2–P5

Off

No connection has been established.

On

A connection has been established.

Table 2.  SmartStack STS-5SU LINK LEDs