SSIM-T8-04 Token Ring

SmartStack Interface Module

Introduction

The SmartStack SSIM-T8-04 provides four additional Token 
Ring ports for the base SmartStack STS16-20RM or FRM 
Token Ring Switch. These ports are IEEE 802.5J compliant.

Figure 1.  SmartStack SSIM-T8-04 Front Panel

The SSIM-T8-04 ports support Token Ring multimode fiber 
media via dual ST-compatible optical receptacles. Each port 
provides either shared (half-duplex), 4 or 16 Mbps 
connections to 802.5j compliant ports (like TRFOT-2), or full-
duplex 32 Mbps connections to another SmartStack SSIM-T8-
04 Interface Module. In addition to the Token-Ring 
connectors, there are ten LEDs on the SSIM-T8-04 front 
panel. These LEDs indicate the operational status of the SSIM-
T8-04 and the ports.

SSIM-T8-04 Module Package Contents

Your interface module package contains the following items:

One SSIM-T8-04 SmartStack Interface Module for the 
SmartStack Token Ring Switch

One SSIM-T8-04 SmartStack Interface Module 
Installation Guide (this document)

Installation

1. Power off the base switch by unplugging it.

2. Remove the plate covering the expansion slot on the front 

of the base switch by unscrewing the two retaining 
thumbscrews. Keep the plate for use in the event that the 
interface module is ever removed.

3. Carefully insert the SSIM-T8-04 into the rails on each side 

of the expansion slot, sliding it back until the connector on 
the module is seated into the connector at the back of the 
slot. When the SSIM-T8-04 is fully seated, its faceplate 
will be flush with the front of the base switch.

4. Secure the interface module with the two attached 

thumbscrews.

Cabling

For backbone cabling, 62.5/125 micron, multimode optical 
fiber cable that meets the ISO/IEC 11801 standard or the EIA/
TIA 568A standard, is recommended. The recommended 
maximum cable length is 2000 m (1.2 mi). Each port is 
terminated in an ST fiber connection. The correct cable 
connection is Fiber Transmitter to Fiber Receiver.

The ST connectors marked TX/RX send/receive 850 nm 
infrared light to an attached device.

LEDs

Table 1 lists the two status LEDs on the left front of the 
interface module and their meanings. Table 2 lists the port 
LEDs on the right of the interface module and their meanings.

Note: Both status LEDs are on for several seconds after a 
reset. The LEDs go off before the start of diagnostics.

Table 1.  Status LEDs and their Meanings

Table 2.  Port LEDs and their Meanings

Testing the Interface Module

1. Power on the base switch to start diagnostics. The 

SmartStack Token Ring switch indicates that diagnostics 
are in progress by turning on its DIAG LED. After about a 
minute, the interface module DIAG LED will also be 
turned on.

2. Verify that the base switch diagnostics have been 

completed successfully. On the SmartStack Token Ring 
switch this is indicated when its DIAG LED is turned off, 
and the ERR LED stays turned off. Diagnostics can take up 
to four minutes to complete.

3. Verify that the ERR LED on the interface module is off. If 

it is off, diagnostics have been successfully completed, and 
the SSIM-T8-04 is ready for configuration.

Configuration

The SSIM-T8-04 ports can be configured just like the base 
switch ports. They will appear as additional ports on any 
configuration panel where ports are listed. The port numbers 
will begin where the numbers of the base switch stop.

If for example the base switch has 20 ports and an interface 
module in the left front panel slot, the module ports will appear 
after Port 20 on the various port configuration panels and be 
designated 21, 22, 23 and 24. If the module is in the right front 
panel slot, the ports will be designated 25, 26, 27 and 28.

Follow the instructions contained in the SmartStack STS16-
20RM/STS16-20FRM Token Ring Switch, Installation and 
User Guide
 for configuring the interface module ports.

When connecting one STS16-20RM switch to another STS16-
20RM switch using the SSIM-T8-04 Interface Module, one 
end of the fiber connection must be manually configured as 
“ADAPTER”, and the other end as “PORT”. Use the 
SmartStack Token Ring Switch Port Configuration menu.

When connecting ports on the SmartStack SSIM-T8-04 
Interface Module to non IEEE 802.5j compliant devices, the 
Interface Module fiber ports must be manually set to RI/RO 
port mode to ensure that a connection can be established.

When connecting ports on the SmartStack SSIM-T8-04 
Interface Module to other fiber equipment that supports FDX 
(full-duplex) connections, the interface module fiber ports 

1

2

TX

TX

RX

TX

RX

3

RX

TX

RX INS

4

ACT

ACT

ACT

ACT

ERR

INS

INS

INS

DIAG

LED

Position

State

Meaning

DIAG 
(green)

Top

On

Diagnostics are in 
progress.

Off

The interface module is 

working correctly.

ERR 

(yellow)

Bottom

On

A interface module 

failure has occurred.

Off

The interface module is 
working correctly.

LED

Position

State

Meaning

INS 
(green)

Top

On

The attached device is 
connected to the interface 

module port.

ACT 
(green)

Bottom

On or 
blinking

Data is being transmitted 
or received by the port.