Operating Specifications

General

 

Receive Sensitivity:

-31.5 dbm typical; -29.5 dbm worst case

Max. Receive Input Power:  

-7.6 dbm typical; -8.2 dbm worst case

Bit Error Rate: Better than 10-10 error rate

Transmitter Peak Wavelength:

820 nm typical; 790 nm min.; 860 nm max.

Spectral Width: 75 nm max.

Rise Time: 10 nsec max.

Fall Time: 10 nsec max.

 

Transmitter Power

 

Into 50/125 

 

µ

 

m fiber:

-13.0 dbm typical; -15.0 dbm worst case
17.5 db typical budget; 13.0 db worst case budget

Into 62.5/125 

 

µ

 

m fiber:

-10.0 dbm typical; -12.0 dbm worst case
20.5 db typical budget; 16.0 db worst case budget

Into 100/140 

 

µ

 

m fiber:

-7.0 dbm typical; -9.0 dbm worst case
23.5 db typical budget; 19.0 db worst case budget

 

Note:

 

 All transmitter readings are peak power.

 

AUI 15 Pin D-Type Connector

Power Supply

 

Current: 280 mA typical; 500mA worst case

Input Voltage: 12.0 Vdc typical; 9.0 Vdc min.;

15.75 Vdc max.

 

Environmental

 

Operating temperature: 0 to 55

 

°

 

C (131

 

°

 

F)

 

Note:

 

 The transceiver case serves as a heat sink. It is 

normal for the case to feel extremely warm. 

 

Operating Humidity: 5 to 95% (non-condensing)

 

Safety

 

Designed in accordance with UL478, UL910, NEC 
725-2(b), CSA, IEC, TUV, VDE Class B. Meets FCC 
Part 15, Class B limits.

 

Note:

 

 It is the responsibility of the person who sells the 

system to which the FOT-F will be a part to ensure that 
the total system meets allowed limits of conducted and 
radiated emissions. 

 

Installation 

 

To install your FOT-F, set the transceiver’s SQE 
switch, connect the AUI cable to an Ethernet device, 
cquirements listed previously in this guide, and the 
guidelines listed in the following sections.

 

Setting the SQE Switch

 

The SQE switch is a two position switch on the top of 
the transceiver. The FOT-F is shipped with the SQE 
switch in the on position (O). To disable the SQE test 
function, slide the SQE switch toward the off position 
(O), as indicated on the front of the transceiver. 

 

Caution:

 

 You must disable the SQE test function if you 

connect the FOT-F to a repeater or to an Ethernet Ver-
sion 1 device. In addition, some Version 2 equipment 
does not support SQE Test. Devices that do not sup-
port the SQE Test function will interpret the SQE test 
pulse as a collision, which will cause poor network per-
formance.

 

Connecting the FOT-F to the Network

 

1. Remove the plastic covers from the fiber optic ports 

on the FOT-F and from the ends of the connectors 
on each fiber cable.

2. Being careful not to touch the ends of the connec-

tors, attach a fiber cable from the transceiver TX 
port, to the RX port on the network device. Like-
wise, attach a fiber cable from the RX port on the 
transceiver, to the TX port on the network device

 

 

Caution:

 

 If you have SMA 906 connectors, make sure 

that each connector has a half alignment sleeve in 
place. A full alignment sleeve will damage the trans-
ceiver port. 

 

3. Attach the FOT-F AUI cable to the Ethernet device. 

4. Check the LANVIEW® LEDs. The PWR LED should 

be lit to indicate that the transceiver is receiving 
power through the AUI cable. The LNK LED should 
be lit to indicate that you have a link between the 
transceiver and the network device. The SQE LED 
will be lit if you have the SQE test function enabled.

 

Using LANVIEW

 

The FOT-F uses Cabletron Systems’ built-in diagnostic 
and status monitoring system, LANVIEW. The LAN-
VIEW LEDs give you a visual indication of network ac-
tivity and can help isolate problems.

 

Power (PWR) LED

 

When lit, this green LED indicates that the FOT-F is re-
ceiving power though its AUI connector. If the PWR 
LED is not lit, power is not being received or the DC-to-
DC converter in the transceiver has failed.

 

Signal Quality Error (SQE) Test Function LED

 

When lit, this yellow LED indicates that the trans-ceiv-
er’s SQE test function is on. The SQE test is used to 
ensure that the collision presence circuit and the path 
between the Ethernet device and the transceiver are 
operational. This test is generated by the transceiver 
after a data packet has been transmitted through the 
transceiver.

O
O
O
O
O
O
O
O

O
O
O
O
O
O
O

8 Logic Ref

7 No Connection

6 Power Return

5 R

4 Logic Ref.

3 Tr

2 Col

1 Logic Ref.

15 No Connection

14 Logic Ref.

13 Power (+12Vdc)

12 Receive -

11 Logic Ref.

10 Transmit -

   9 Collision -

SMA 905 Connector

SMA 906 connector with
Half Alignment sleeve

ST Connector

SN

SQE

TX

RX

FOT-F24

S

Q

E

X

M

T

R
C
V

C

L

N

L

N
K

P

W

R

802.3 10BASE-FL/FOIRL
TRANSCEIVER
 

WITH

 LANVIEW

®

b

Reviews: