background image

 

Power Supply Operation

Page 2

PN 9031984-01

 

Power Supply Operation

 

The ESX-1320R and the ESX-1380R are equipped with two load sharing power 
supplies to provide redundancy. Two power cord outlets, labeled Power 1 and 
Power 2 (see Figure 1), are used to provide power to each power supply. To take 
advantage of the load sharing and redundancy capabilities, each power cord must 
be plugged into a dedicated ac outlet.

 

LANVIEW Diagnostic LEDs

 

In addition to the LANVIEW LEDs located on the front panel of the ESX-1320 
and the ESX-1380, the ESX-1320R and the ESX-1380R are equipped with two 
LANVIEW diagnostic LEDs located on the rear of the unit (see Figure 1). These 
LEDs provide an easy way to observe the status of the individual power supplies. 
Table 1 provides a description of the LANVIEW power supply LEDs.

 

Physical Properties (ESX-1320R or ESX-1380R)

 

Dimensions:

6.86H x 43.18W x 46.99D (cm)
2.7H x 17W x 18.5D (in)

Weight (Unit):

5.45 kg (12 lb)

 

Electrical Specifications (ESX-1320R or ESX-1380R)

 

Input:

100-125 V ~ /4.0 A
200-250 V ~ / 2.0 A

Phasing:

Single-phase

Frequency:

50/60 Hz

 

Table 1  LANVIEW Power Supply LEDs

LED

Color

Description

 

PWR 1

Green

Power Supply 1 is operating correctly.

Red

Power Supply 1 is not operational.

PWR 2

Green

Power Supply 2 is operating correctly.

Red

Power Supply 2 is not operational.