Chapter 4: CSMIM-T1 Parameters
4-4
CSMIM-T1 Hardware Installation Guide
Online
When illuminated, the T-1 engine is engaged with the
network. Otherwise, the T-1 Network Interface and
Drop/Insert Interface are isolated from the T-1 engine.
Up Time
Amount of time the T-1 engine has been up, in hours,
minutes, and seconds. The “hours” field is a 16-bit register
that can count up to 2700 days (less than 7 years).
Serial Number
The T-1 engine’s serial number.
Circuit ID
The T-1 engine’s Circuit ID displayed from the tni_circuit_id
parameter.
Unit ID
The T-1 engine’s Unit ID displayed as:
“XYLOGICS T1-ENGINE 085nnn Rev. n mm/dd/yy xxxx”
Where:
085nnn - This is the firmware number.
Rev. n - This is the firmware revision number.
mm/dd/yy - This is the firmware release date.
xxxx - This is the EPROM check sum.
DII Sync
When DII Sync is true, the Drop/Insert Interface is receiving
ones pulses and is in frame sync. When DII Sync is false, the
Drop/Insert Interface is out of frame sync or not receiving
pulses and is sending AIS (all ones framed).
Interval
The 15-minute interval being displayed. This is an integer
from 1 to 96, “current” or “total”.
Number of Valid
Seconds
Part of the “current” report that indicates the number of
seconds for which the statistics data has been collected.
Number of
15-minute
Periods
Part of the “total” report that indicates the number of valid
15-minute periods. This could also be derived from the
uptime.
Bursty Errored
Seconds
A Bursty Errored Second (BES) is a second with more than
one, but less than 320 CRC error events.
Controlled Slip
Seconds
A Controlled Slip Second (CSS) is a second with one or more
Controlled Slips.
Table 4-3
stats-T Command Information
Field
Description
Summary of Contents for CSMIM-T1
Page 2: ......
Page 8: ...viii CSMIM T1 Hardware Installation Guide ...
Page 26: ...Chapter 1 INTRODUCTION 1 14 CSMIM T1 Hardware Installation Guide ...
Page 84: ...Chapter 4 CSMIM T1 Parameters 4 16 CSMIM T1 Hardware Installation Guide ...
Page 184: ...Chapter 7 AT Commands and Registers 7 58 CSMIM T1 Hardware Installation Guide ...
Page 188: ...Appendix A PORT PIN SIGNAL ALLOCATIONS A 4 CSMIM T1 Hardware Installation Guide ...