9032031-01

 

SmartSwitch 9500 

9A656-04 ATM Module

Hardware and Installation Guide

Summary of Contents for 9A656-04

Page 1: ...9032031 01 SmartSwitch 9500 9A656 04 ATM Module Hardware and Installation Guide ...

Page 2: ......

Page 3: ... CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Copyright April 1998 by Cabletron Systems Inc 35 Industrial Way Rochester NH 03867 5005 All Rights Reserved Printed in the United States of Ame...

Page 4: ...in which case the user will be required to correct the interference at his own expense WARNING Changes or modiÞcations made to this device which are not expressly approved by the party responsible for compliance could void the userÕs authority to operate the equipment VCCI Notice This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Techno...

Page 5: ...ipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ____________________________________________________ ______________________________________________________ Full Name Full...

Page 6: ...Notice iv ...

Page 7: ...anuals 1 5 Getting Help 1 6 Chapter 2 Installing the 9A656 04 Module The Reset Switch 2 3 The Module Card DIP Switch 2 4 Installing an ANIM 2 5 Chapter 3 Operation ATM Cell TrafÞc Flow in the 9A656 04 3 2 Cell Transfer Matrix CTM 3 2 Cabletron Systems ASICs 3 2 i960HD Processor 3 3 System Management Buses 3 4 SMB 1 Bus 3 4 SMB 10 Bus 3 4 System Diagnostic Controller 3 5 DC DC Converter 3 5 ...

Page 8: ...rating SpeciÞcations 5 1 Environmental Requirements 5 1 Regulatory Compliance 5 1 Service 5 1 Physical 5 2 Device SpeciÞcations 5 2 ANIM SpeciÞcations 5 2 ANIM 21 3 5 3 ANIM 29 3 5 4 ANIM 29 3LR 5 5 ANIM 31 2 5 6 ANIM 39 2 5 7 ANIM 39 2LR 5 8 ANIM 67 2 5 9 ANIM 77 2 5 10 ANIM 22 4 5 11 ...

Page 9: ...verview of the 9A656 04 Installing the 9A656 04 in the SmartSwitch 9500 chassis Installing ATM Network Interface Modules ANIMs Learning the hardware speciÞcations of the 9A656 04 and the available ANIMs Prior to installing the 9A656 04 you should have a working knowledge of ATM networking principles In this document the Cabletron Systems SmartSwitch 9000 chassis is referred to as the SmartSwitch 9...

Page 10: ...link between each 9A656 04 module Through its distributed switching architecture the 9A656 04 allows all the modules in the chassis to appear as a single entity with a single IP address and a single ATM address The individual i960 processors and the CTM backplane interfaces are transparent to the network manager and management applications A fully loaded SmartSwitch 9500 chassis appears as a singl...

Page 11: ...1 3 Overview Figure 1 1 The 9A656 04 AN AN AN AN 2031_01 ...

Page 12: ...itch 9500 chassis IP address assignment Ability to conÞgure the in band management LAN Emulation Client SmartSwitch 9500 chassis and 9A656 04 SNMP community names and trap IP address assignment Ability to access Local Management screens of any module installed in the chassis Connectivity The 9A656 04 can be equipped with a variety of front panel interfaces called ATM Network Interface Modules ANIM...

Page 13: ...sted below should be used to supplement the procedures and technical data contained in this manual 9A656 04 ConÞguration Guide SmartSwitch 9000 Installation Guide SmartSwitch 9000 Operations Guide SmartSwitch 9000 9C300 1 Environmental Module UserÕs Guide SmartSwitch 9000 9C214 1 AC Power Supply UserÕs Guide SmartSwitch 9000 Local Management UserÕs Guide SmartSwitch 9000 6 9C106 Setup and Installa...

Page 14: ... and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers Phone 603 332 9400 Internet mail support ctron com FTP ctron com 134 141 197 25 Login anonymous Password your email address BBS 603 335 3358 Modem setting 8N1 8 data bits No parity 1 stop bit For additional...

Page 15: ... Immediately contact the Cabletron Systems Global Call Center 5 Install the 9A656 04 module in the chassis by aligning the module card between the upper and lower metal slot guides of any available slot sliding it into the chassis and locking down the top and bottom plastic tabs as shown in Figure 2 1 Take care that the 9A656 04 slides in straight and properly engages the backplane connectors CAUT...

Page 16: ...Installing the 9A656 04 Module 2 2 Figure 2 1 Installing the 9A656 04 2031_02 AN AN AN AN Circuit Card Card Guides Metal Back Panel Plastic Locking Tab Plastic Locking Tab ...

Page 17: ...dule to shutdown Pressing and holding the button again for three seconds restarts the module SNMP management may be used to disable this switch to enhance module security Figure 2 2 The Reset Switch CAUTION Resetting the 9A656 04 will cause a brief period of system downtime When the interface module is reset the remaining modules attached to the CTM go through an initialization process to determin...

Page 18: ...tored in NVRAM and restores the default passwords Once reset you can use the defaults or enter new passwords 7 Clear NVRAM The module uses NVRAM to store user entered parameters such as IP addresses device name etc To reset these parameters to the factory defaults toggle this switch Once reset you can use the defaults or enter new parameters which are stored in NVRAM when the module is powered dow...

Page 19: ...nectors and the 16 standoff screws for the ATM Network Interface Modules ANIMs Figure 2 3 also shows the location of the Module Card DIP Switch Figure 2 3 ANIM Connector Locations and Module DIP Switch Location ANIM Connectors 4 Standoff Screws 16 2031_04 i960 Processor 1 2 3 4 5 6 7 8 DIP Switch ...

Page 20: ... Save the screws 3 Lift and remove the coverplate from the top of the front standoffs Figure 2 4 Removing the Coverplate 4 Refer to Figure 2 5 Hold the ANIM by the provided cutouts on the board of the ANIM CAUTION The ANIM and 9A656 04 module are sensitive to static discharges Use a grounding strap and observe all static precautions during this procedure Failure to do so could damage the ANIM and ...

Page 21: ...peat steps 2 through 6 to install each one Figure 2 5 Installing an ANIM CAUTION When installing or removing an ANIM make sure to always use the cutouts on the board to handle the ANIM See Figure 2 6 for the location of the cutouts When connecting the ANIM pins to the motherboard connector take extra precaution that the pins do not enter the connector at an angle as this will damage both the ANIM ...

Page 22: ...Installing the 9A656 04 Module 2 8 ...

Page 23: ...6 04 Block Diagram TDM Bus Phycsical Connection to Network ATM CELLS ATM CELLS UTOPIA ASICs Separates assembles cell header data Translates headers and provides routing information to move ATM cells out of the TDM TDM ASIC Segments and reassembles data into ATM cells SARI ASIC DATA To SMB 1 10 To Z 80 Processor DATA DATA CTM BACKPLANE INTERFACES CTM ASICs ROUTING INFORMATION CELL HEADER INFORMATIO...

Page 24: ... Cabletron Systems ASICs The 9A656 04 SmartSwitch utilizes Þve separate Cabletron Systems designed ASICs to perform switching functions Refer to Figure 3 1 to see how these Þve ASICs work together to provide proper trafÞc ßow The deÞnitions for these ASICs are as follows Queue ASIC The 9A656 04 has four Queue ASICs installed on the motherboard These ASICs support 16 priority queues each The Queue ...

Page 25: ... backplane Utopia Universal Test and Operation Physical Interface ASICs The 9A656 04 has four Utopia ASICs whose role is to process ATM cells from the ANIMs to the TDM Bus and vice versa In addition the Utopia ASICs are responsible for performing path lookups and outbound header translation i960HD Processor The i960HD processor working with the Þve types of ASICs deÞned earlier is responsible for ...

Page 26: ...bus to ensure the validity of SMB 1 In the event a failure is detected on SMB 1 the SMB 10 may be used as an alternate communication channel SMB 10 Bus The SMB 10 is a 10 Mbps management bus located within the SmartSwitch 9500 chassis which is also used for inter chassis communication of modules as well as serving as an out of band management channel into the SmartSwitch 9500 The SMB 10 is externa...

Page 27: ... host processor can operate independently of each other if needed they exchange information about each otherÕs status and overall module condition The information gathered by the diagnostic controller is available to the network manager via Local Remote Management and the LCD located on the environmental module The 9A656 04 has been designed so that in the event of a diagnostic controller fault th...

Page 28: ...Operation 3 6 ...

Page 29: ...status of the module and may be used as an aid in troubleshooting Shown in Figure 4 1 are the LANVIEW LEDs of the 9A656 04 module Refer to Table 4 1 for the full deÞnitions of 9A656 04 LED states Figure 4 1 9A656 04 LANVIEW LEDs System Status SMB Status 2031_09 9A656 04 ...

Page 30: ...ion SMB Green Functional Fully operational Amber Crippled Not fully operational i e one bad port Off Power off Module powered off CPU Amber Green Booting LED blinks amber and green while booting Red Flashing Failed Fatal error has occurred Off Power off Module powered off ...

Page 31: ...LANVIEW LEDs of all ANIMs Although there are several types of ANIMs all share the same LANVIEW LEDs Refer to Table 4 2 for the full deÞnitions of ANIM LED states Figure 4 2 ANIM LEDs Table 4 2 ANIM LEDs LED LED Color Status LNK Green Link Off No Link STS Green Port Enabled and OK Amber Standby Red Port Enabled and Error ATM Link ATM Status 2031_10 ...

Page 32: ...LANVIEW LEDs 4 4 ...

Page 33: ...e Temperature 30 C to 73 C 22 F to 164 F Operating Relative Humidity 5 to 90 non condensing Regulatory Compliance Safety This equipment meets the safety requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 and 73 23 EEC Electromagnetic Compatibility This equipment meets the requirements of FCC Part 15 EN 55022 VCCI V 3 CSA C108 8 EN 50082 1 AS NZS 3548 and 89 336 EEC Service MTBF MHBK 217E 20...

Page 34: ...Processor Intel i960HD RISC processor control Dynamic Random Access Memory DRAM 96 MB FLASH Memory 8 MB ANIM Specifications The 9A656 04 uses ATM Network Interface Modules ANIMs to provide front panel cable connections The ANIMs should be installed by qualiÞed personnel Refer to the section in Chapter 2 entitled Installing an ANIM for full instructions on the installation process ...

Page 35: ...2 Mbps The speciÞcations for the ANIM 21 3 are listed in Table 5 1 Figure 5 1 ANIM 21 3 Table 5 1 ANIM 21 3 Specifications Parameter SpeciÞcation Number of Interfaces 3 Line Rate 155 52 Mbps Interface Type Duplex SC Media Type Multimode Fiber Frame Type SONET SDH Typical Range 2 km Loss Budget TX 17 db to 12 db RX 27 db to 12 db 2031_11 ...

Page 36: ...5 52 Mbps The speciÞcations for the ANIM 29 3 are listed in Table 5 2 Figure 5 2 ANIM 29 3 Table 5 2 ANIM 29 3 Specifications Parameter SpeciÞcation Number of Interfaces 3 Line Rate 155 52 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 15 km Loss Budget TX 15 db to 8 db RX 31 db to 8 db 2031_11 ...

Page 37: ...2 Mbps The speciÞcations for the ANIM 29 3LR are listed in Table 5 3 Figure 5 3 ANIM 29 3LR Table 5 3 ANIM 29 3LR Specifications Parameter SpeciÞcation Number of Interfaces 3 Line Rate 155 52 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 60 km Loss Budget TX 15 db to 8 db RX 31 db to 8 db 2031_11 ...

Page 38: ... 622 Mbps The speciÞcations for the ANIM 31 2 are listed in Table 5 4 Figure 5 4 ANIM 31 2 Table 5 4 ANIM 31 2 Specifications Parameter SpeciÞcation Number of Interfaces 2 Line Rate 622 Mbps Interface Type Duplex SC Media Type Multimode Fiber Frame Type SONET SDH Typical Range 2km Loss Budget TX 19 db to 14 db RX 26 db to 14 db 2031_12 ...

Page 39: ...22 Mbps The speciÞcations for the ANIM 39 2 are listed in Table 5 5 Figure 5 5 ANIM 39 2 Table 5 5 ANIM 39 2 Specifications Parameter SpeciÞcation Number of Interfaces 2 Line Rate 622 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 15 km Loss Budget TX 15 db to 8 db RX 28 db to 7 db 2031_12 ...

Page 40: ...622 Mbps The speciÞcations for the ANIM 39 2LR are listed in Table 5 6 Figure 5 6 ANIM 39 2LR Table 5 6 ANIM 39 2LR Specifications Parameter SpeciÞcation Number of Interfaces 2 Line Rate 622 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 60 km Loss Budget TX 15 db to 8 db RX 28 db to 7 db 2031_12 ...

Page 41: ...ectors with a line rate of 45 Mbps The speciÞcations for the ANIM 67 2 are listed in Table 5 7 Figure 5 7 ANIM 67 2 Table 5 7 ANIM 67 2 Specifications Parameter SpeciÞcation Number of Interfaces 2 Line Rate 45 Mbps Interface Type BNC Media Type Coaxial Cable Frame Type DS3 Typical Range 185 meters 2 ...

Page 42: ...nnectors with a line rate of 34 Mbps The speciÞcations for the ANIM 77 2 are listed in Table 5 8 Figure 5 8 ANIM 77 2 Table 5 8 ANIM 77 2 Specifications Parameter SpeciÞcation Number of Interfaces 2 Line Rate 34 Mbps Interface Type BNC Media Type Coaxial Cable Frame Type E3 Typical Range 185 meters 2 ...

Page 43: ...ors with a line rate of 155 52 Mbps The speciÞcations for the ANIM 22 4 are listed in Table 5 9 Figure 5 9 ANIM 22 4 Table 5 9 ANIM 22 4 Specifications Parameter SpeciÞcation Number of Interfaces 4 Line Rate 155 52 Mbps Interface Type RJ45 Media Type Category 5 UTP Frame Type SONET SDH Typical Range 100 meters ...

Page 44: ...General Specifications 5 12 ...