Cablematic SimPal-T4 User Manual Download Page 28

SimPal-T4 POWER SOCKET USER MANUAL

3.5 Delay control the socket output

Description

The socket output can be set to delay switch ON/OFF for a period time. 

Delay   control   function   will   auto   deactivate   once   manual   change   socket   status   by

sending SMS or M button, activate calendar control or thermostat control will also deactivate

the delay control function.

When the “delayed switch on the socket” command  is  received and if  the  socket

output is switched on, the socket output will be switched off immediately and be switch on

again as the setting delayed time is reaching. Contrarily, if the socket output is switched off,

28

Summary of Contents for SimPal-T4

Page 1: ...SimPal T4 GSM Power Socket User Manual Manual version 2 0...

Page 2: ...wer Socket Thank you for purchasing the SimPal T4 SimPal T4 GSM power socket is a remote controlled socket consisting of a GSM module The power supply output can be turned on or off remotely by the SM...

Page 3: ...AL All services and functions need to be supported by the GSM network and a SIM card This brochure suits for SimPal T4 model Details of the functioning and advanced operation of this socket are descri...

Page 4: ...Package contents 10 1 2 Sockets instructions 11 1 3 Light indicator 13 2 1 User authorization level 14 2 2 About the SMS Command 15 3 1 Start to use 15 3 2 1 Register Master number 17 3 2 2 Change Mas...

Page 5: ...lendar control 21 3 6 1 Activate calendar control 21 3 6 2 Set calendar 22 3 6 3 Deactivate calendar control 24 3 7 Thermostat control 24 3 7 1 Activate thermostat function 24 3 7 2 Set thermostat con...

Page 6: ...SMS when power lost or restore 28 3 11 SMS notification to User 28 3 12 Check status 29 3 13 Weak GSM signal notification 30 3 14 Change password 31 3 15 Resetting the socket 31 4 Main Technical Param...

Page 7: ...ard number is referred as SimPal T4 number on this brochure 2 The user needs to activate the Caller ID Presentation function of SIM card and deactivate PIN code of the SIM Contact with GSM network ser...

Page 8: ...SimPal T4 POWER SOCKET USER MANUAL this information to anyone other than the authorized users in order to ensure your safety 8...

Page 9: ...ample iatrical appliances large heaters and refrigerates Before using this socket make sure that the mobile phones can be used well in the area otherwise do not put this socket into operation The powe...

Page 10: ...y aggressive or dusty environment Do not open the case unless maintenance needed Do not keep shaking or fall down this socket otherwise it can be damaged This socket is a wireless signal transmission...

Page 11: ...ets etc Do not cast this socket in a fire as this may cause explosion This socket should only be operated from power approved by the socket manufacturer The use of any other types of power may damage...

Page 12: ...the latest socket information please visit http www simpal cn We don t guarantee for the document veracity reliability or any content except regulate in proper laws Including no guarantee for socket s...

Page 13: ...is Except as required by applicable law no warranties of any kind either expressed or implied including but not limited to the accuracy reliability or contents of this document We reserve the right to...

Page 14: ...SimPal T4 POWER SOCKET USER MANUAL 1 1 Package contents 14...

Page 15: ...SimPal T4 POWER SOCKET USER MANUAL 1 2 Sockets instructions 15...

Page 16: ...SimPal T4 POWER SOCKET USER MANUAL 16...

Page 17: ...SimPal T4 POWER SOCKET USER MANUAL Figure 2 Temperature sensor Instruction 17...

Page 18: ...mPal T4 Power icon indicator Turning off Socket power output OFF Constant light Socket power output ON Wireless icon indicator Flash slowly Searching GSM network Slowly breath Working in standby mode...

Page 19: ...and There are two mobile phone user controlling levels Master user Master Only one Master has authorization to use all features of SimPal T4 In order to enable all the functions on the socket the Mast...

Page 20: ...output check socket temperature value or receive power status change alert The other mobile phone users have no authorization to control the socket 2 2 About the SMS Command SMS command format code c...

Page 21: ...ommands 3 1 Start to use Installed SIM card to SimPal T4 GSM power socket you will see a SIM card slot at the side make the SIM card metal contact upside and hardly push the SIM card until SIM card fi...

Page 22: ...cket default power output is OFF 2 Insert the plug of electronic appliance in the SimPal T4 electrical outlet 3 M button See 5 on Figure1 can be pressed for about one second to switch on or off the so...

Page 23: ...e Therefore before using the user should ensure that socket is used in an area with a strong GSM network signal For the first time use the user should perform a test run by sending SMS to the socket T...

Page 24: ...e the Master number Register Master number on the socket 00 1 3 2 2 Change Master number Master sends following SMS message in order to Change master number 14 NewMasterNumber 2 NewMasterNumber should...

Page 25: ...mber can be stored on GSM socket Family number has the authority to send SMS command to switch on or cut off the socket power output Method Master sends following SMS message in order to Register a Fa...

Page 26: ...USER MANUAL 3 3 2 Check Family number Master sending SMS to check Family number 06 4 3 3 3 Delete Family Method Master sends following SMS message in order to Delete a Family 15 Family Number 5 Delet...

Page 27: ...MANUAL 3 4 Control socket power Method Method 1 To press M button one second See 5 on Figure1 Method 2 Master sends following SMS message to socket in order to Turn ON socket power output 01 0 7 Turn...

Page 28: ...change socket status by sending SMS or M button activate calendar control or thermostat control will also deactivate the delay control function When the delayed switch on the socket command is receiv...

Page 29: ...llowing SMS message in order to Delay switching ON output after a certain minutes 12 0 Minutes 1 9 Delay switching OFF output after a certain minutes 12 0 Minutes 0 10 Minutes are time parameters its...

Page 30: ...The socket output can be set to switch on for duration and then be switch off after the duration Calendar control function will auto deactivate if user manually change the socket status by SMS or M b...

Page 31: ...function 19 0 1 11 Socket will auto switching on or off the output according to the schedule settings 3 6 2 Set calendar Description After successful setting of time duration to switch on the socket...

Page 32: ...essage in order to Set time period to switch on the socket output 20 0 WorkDay StartTime EndTime 12 WorkDay one digit the values lie in the range of 0 to 8 The following table contains the description...

Page 33: ...T4 POWER SOCKET USER MANUAL 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday 8 Monday to Friday 9 Weekend StartTime and EndTime Be consists of 4 digits hh mm and works on a 24 hour clock...

Page 34: ...socket output will switch on at the StartTime and cut off at the EndTime For example 20 0 1 0000 2130 0 means the SimPal T4 0000 means time 00 00 hh mm AM 2130 means time 9 30PM 3 6 3 Deactivate cale...

Page 35: ...e sensor must be inserted into the I O port of socket The socket power output can be auto controlled according environment temperature change Thermostat function will auto deactivate if user manually...

Page 36: ...n temperature lower than smaller temperature value and turn off when higher than bigger temperature value Cooling mode socket will auto turn on when temperature higher than bigger temperature value an...

Page 37: ...stat control parameters 24 0 mode low temp high temp 15 Mode parameter can be 1 or 2 Warming mode is 1 cooling mode is 2 Temp range should be within 10 to 50 degree For example 24 0 1 15 25 it means s...

Page 38: ...er successful setting of temperature range the temperature parameter will be saved on the socket until socket reset to factory settings 3 7 3 Deactivate thermostat control function Method Master sends...

Page 39: ...t In this case if the surroundings temperature is detected out of the pre set temperature range SimPal T4 socket will auto send the SMS alarm message to your mobile phone This feature depends on the t...

Page 40: ...alues can be set within the range of 10 to 50 centigrade degree Deactivate temperature alarm 21 0 0 19 3 9 SMS when on off button pressed Description SimPal T4 socket will default sending SMS notify M...

Page 41: ...when on off button pressed Default 03 1 20 Deactivate SMS when on off button pressed 03 0 21 3 10 SMS when power lost or restore Description SimPal T4 socket will default sending SMS notify when main...

Page 42: ...ate SMS when power lost or restore 05 0 23 3 11 SMS notification to User SimPal T4 socket will sending SMS alert when mains power lost restore temperature alert or other information Default sending SM...

Page 43: ...eactivate SMS alert to User 16 0 25 3 12 Check status Method Master or Family sends following SMS message in order to Check socket operating status 07 0 26 Check delayed control parameters 34 27 Check...

Page 44: ...send a SMS notification when the GSM signal strength is too weak The Master user can enable disable this SMS notification Method The Master user sends following SMS message in order to set Check GSM...

Page 45: ...Weak GSM signal strength alert function ON OFF The alerter will send SMS message when it alarms Weak GSM signal alert the CSQ is 3 14 Change password Method Master sends following SMS message in order...

Page 46: ...e socket Description This function resets all programmed settings to their original values including cleaning all user number timing parameter and temperature parameter If the setting status is wrong...

Page 47: ...ER SOCKET USER MANUAL SimPal T4 reset factory setting Method 1 Press the side M button of the device for 10 seconds Method 2 Master sends following SMS message in order to Reset SimPal T4 socket 08 pa...

Page 48: ...t 110 230V 50HZ 230V 30A 30s 16A long duration CEE7 4 German Schuko French American Australia Operating temperature 10 50 Store temperature 20 60 Relative humidity 10 90 without condensation Communica...

Page 49: ...ange Master number 2 14 NewMasterNumber Add Family number 3 06 Family Number Check Family number 4 06 Delete Family number 5 15 Family Number Delete all Family number 6 15 Change socket power status C...

Page 50: ...lendar control parameters 12 20 0 WorkDay StartTime EndTime Deactivate calendar control 13 19 0 0 Thermostat control Activate thermostat control 14 23 0 1 Set thermostat control parameters 15 24 0 mod...

Page 51: ...03 1 SMS when on off button pressed function OFF 21 03 0 SMS when power lost or restore Default 22 05 1 SMS when power lost or restore function OFF 23 05 0 SMS notifications SMS alert to User 24 16 1...

Page 52: ...status 28 33 Check Thermostat control status 29 32 Check temp alarm status 30 35 Check GSM signal 31 27 Weak GSM signal alert 32 27 1 Disable weak GSM signal alert 33 27 0 Change password Change passw...

Page 53: ...SimPal T4 POWER SOCKET USER MANUAL 53...

Page 54: ...l l lt a r D A SimPal _...

Reviews: