H) Installation/Positioning of the Cablelock AS retaining system:

Before starting please read and consider the information on the cover page and in the standard 

A) Functional description:

BGI 5100 carefully! Avoid chafing on adjacent components!

The 'AS' retaining system prevents the pressure hose
from uncontrolled whipping into the surrounding area
in case of a tear-out from the crimping ferrule. This is 

      Basic formula for the radius of tear-out:

possible as the Cablelock 'basic' tensioner lock is fixed 

X-Y = min. FL+20mm, max. FL+170mm

to the hose and the fixing bracket to the fixation point through 

 'Length of the cable bow minus shortest distance of the fixation points'

the cable (the fixation point consists of the crimping ferrule
and the hose fitting). The length of the cable has to be 

Position of the tensioner lock 'basic':

dimensioned in that way that there is a possibility for the

Z = min. 50mm, max. 100mm

hose to slip out of the crimping ferrule (to ensure a pressure
release). 

ATTENTION: If the hose is lead in a bend, NEVER install the 

tensioner locks 'basic' in the outer region of the bending radius!

Assembly steps:
1) Enlarge the pre-mounted cable sling by hand and place it moveable on the hose.
2) Attach the bracket and screw down the end of the hose tightly (union nut/external thread or flange plate).

DN5-8 (AD11-19)

3mm

12,5 

x 2,0

CL-AS-E125

DN12-16 (AD19-31)

4mm

8,5 

x 4,0

CL-AS-S085

3) Push the hose-sided tensioner lock 'basic' including the cable sling towards the hose.

DN5-8 (AD11-19)

3mm

1

4,5 

x 2,0 

CL-AS-E145

DN20-25 (AD26-44)

4mm

10,5 

x 4,0 

CL-AS-S105.1

     The hose-sided fixpoint has to be located 50mm to 100mm behind the end of the crimping ferrule.

DN5-8 (AD11-19)

3mm

17,0 

x 2,0

CL-AS-E170

DN32 (AD43-52)

5mm

10,5 

x 4,0

CL-AS-S105.2

DN5

450bar

60mm

-

0,40

4) If the hose-sided fixation point is chosen according to 3) attach the Cablelock AS-Tape if desired.

DN8-10 (AD14-23)

3mm

18,5 

x 2,0 

CL-AS-E185

DN20-25 (AD26-44)

4mm

12,5 

x 4,0

CL-AS-S125.1

DN6

450bar

75mm

150mm

0,65

    Afterwards install the tensioner lock 'basic' according to the enclosed installation manual starting at point D4).

DN8-10 (AD14-23)

3mm

20,5 

x 2,0 

CL-AS-E205

DN32-50 (AD43-74)

5mm

12,5 

x 4,0

CL-AS-S125.2

DN8

450bar

85mm

-

0,70

5) Please make sure that the brackets of the 'E' series are able to rotate even after final assembly (after union nut

DN10-12 (AD17-28)

3mm

22,5 

x 2,5 

CL-AS-E225

DN25 (AD34-44)

4mm

14,5 

x 4,0

CL-AS-S145.1

DN10

450bar

90mm

150mm

0,85

     has been tightened firmly).

DN10-12 (AD17-28)

3mm

24,5 

x 2,5 

CL-AS-E245

DN32 (AD43-52)

5mm

14,5 

x 4,0

CL-AS-S145.2

DN12

450bar

130mm

200mm

1,15

6) The brackets of the 'S' and 'P' series always have to be installed with the appropriate screws (not too small and 

DN16-20 (AD23-35)

4mm

27,0 

x 2,5 

CL-AS-E270

DN32-40 (AD43-61)

5mm

16,5 

x 4,0

CL-AS-S165

DN16

420bar

150mm

240mm

1,40

    at least 8.8). Furthermore they have to be installed with the torque recommended in the DIN, so that the head 

DN16-20 (AD23-35)

4mm

30,5 

x 3,0

CL-AS-E305

DN40-50 (AD50-74)

5mm

20,5 

x 4,0

CL-AS-S205

DN20

420bar

180mm

240mm

1,80

    of the screw presses against the bracket with this torque. 

DN20-25 (AD26-44)

4mm

34,0 

x 3,0

CL-AS-E340

DN25

420bar

230mm

300mm

2,30

DN20-25 (AD26-44)

4mm

36,5 

x 3,0 

CL-AS-E365

DN32

325bar

420mm

460mm

3,35

Machine-sided fixation points for Cablelock AS (see also text above):

DN20-25 (AD26-44)

4mm

42,5 

x 3,0

CL-AS-E425.1

DN40

290bar

500mm

560mm

3,90

DN32 (AD43-52)

5mm

42,5 

x 3,0 

CL-AS-E425.2

DN5-12 (AD11-28)

3mm

9,0 

x 3,0

CL-AS-P090

DN50

250bar

630mm

660mm

5,30

DN32-40 (AD43-61)

5mm

45,5 

x 3,0

CL-AS-E455

DN16-25 (AD23-44)

4mm

11,0 

x 4,0

CL-AS-P110

DN40-50 (AD50-74)

5mm

49,0 

x 3,0

CL-AS-E490

DN32-50 (AD43-74)

5mm

13,0 

x 4,0

CL-AS-P130

DN32-40 (AD43-61)

5mm

52,5 

x 3,0 

CL-AS-E525

DN40-50 (AD50-74)

5mm

61,0 

x 3,0 

CL-AS-E610

* When correctly installed for hose types 1 & 2SN, 1 & 2SC, 4SP & 4SH (up to DN25 and also for R13 & R15). ATTENTION: Do 

  not use any type for hoses with 6 steel inlays; see also the information below. The above hose types meet the standards below.

** The inner diameter specifications may deviate slightly, but they are suitable for the intended DIN EN connections.
    The strap thickness “t” is generally suitable for conventional standard fittings without terminals, but always under reservation.
*** Cablelock retention systems are exclusively tested for liquid media. All pressure specifications refer exclusively to applications 

using liquid media! In addition to the max. OP (max. operating pressure incl. pressure spikes), the limit values must also always

must also always comply with the right hose data table (values in accordance with the standard or the data of leading hose manufacturers).

Pressure specifications refer to the hose ID, e.g.: type E225-DN10 = r² x p x 450 bar, i.e. 5 mm x 5 mm x 3.14 x 450 bar.

C) Application/Operating conditions and IMPORTANT safety Instructions:

Cablelock retaining systems are supposed to protect against uncontrolled whipping of hydraulic hose assemblies. The information and
instructions in this operating manual must be followed carefully. Failure to comply can lead to failure of the retaining system an possibly
to further risks due to whipping or flying parts of Cablelock! Cablelock retaining systems have been developed and tested in compliance
with the following standards: DIN 20066, DIN EN 853, DIN EN 854, DIN EN 855, DIN EN 856, DIN EN 857 and ISO 3862 - for more
information concerning the hose types see above. If the maximum operating pressure is exceeded, Cablelock retaining system does not
ensure a sufficient protection. In accordance to the company standards reference retaining systems have been dynamically tested in 
quasi-static pressure tests with at least 150% of the maximum operating pressure and have been able to stop the end of the hose reliably. 
Protection provided by Cablelock retention systems shall only be guaranteed if the installation requirements in accordance with DIN 20066  
are complied with and at least the lowest bend radius in accordance with the above standard is used!       The maximum operating
temperature is -40°C up to +150°C. Before installing Cablelock AS it has to be checked that the hose and machine can move safely with 
the protection. It has to be assured that no trapping during movement can occur. Keep away from children! A safety distance must be

I) Storage/Maintenance/Care/Warranty/Manufacturer/Conformity/Sample images: 

adhered to regardless of the attached safety catch (see point F)! The suitability in explosive environments or other special environments

- Cablelock AS retaining system should be stored in a dry and dust free area and they should NOT be dismounted 

(Pharma, foods, radiation etc.) should be agreed with the manufacturer in each individual case. The retaining systems neither protect from

  completely* (see page 2)

the leaking fluid in case of the tear-out of the crimping ferrule, nor from any other fitting parts or the crimping ferrule tearing off in addition

- Cablelock protection devices of this series are rust-protected, but NOT suitable for use in moist conditions! For more

to the hose. Cablelock AS is designed for 4-5 assemblies/disassemblies; more frequent applications might damage components. It

  information see: www.cablelock.de - important information - exclusion of liability/corrosion

has to be ensured that the selected machine fixpoint contains enough stability. Residual risks may remain regardless of the safety catch;

- Do not replace individual components. In case of damage or a retaining action (=hose tear-out) completely replace Cablelock.

the file “possible residual risks”, which includes important information, is available at www.cablelock.de. Cablelock retaining systems are

- Before reuse (if there was no tear-out) check whether the retaining system (especially the cable) is in a functional condition.

not suitable for use in moist conditions, see also point I). Cablelock retaining systems have are not tested for gaseous media - see information

- Limited warranty in case of vibration load, see also the CE label safety catch information sheet at www.cablelock.de 

in catalogue. This series must NOT be used for 6-layer hoses (e.g. R13/R15 fromDN32). The increased weight-per-metre of these hose 

- Check the retaining system regularly for damage and firm fixation (e.g. during the annual pressure inspection as required in 

types compared to 4-layer hoses as well as the increased bending stress at the lowest bend radius may result in the safety catch being 

  DGUV-113-020). In case of excessive vibrations etc. shorten the checking intervals!

overloaded!        It is also extremely important that the Cablelock locks are always sufficiently secured - see section D). The meanings of the 

- If there are signs of corrosion or damage precautionary replace the retaining system!

terms used in these operating instructions are to be understood in the context of DIN EN ISO 8330. In the event of the hose being torn off, 

- Manufacturer: Hydraulik Schmitz Siegen GmbH - Seelbacher Weg 17 - 57072 Siegen 

no part of the safety lock must strike any other components (otherwise the cables may become torn, etc.).

- All images show safety catches with 3 mm wire rope diameter (4+5 mm types may differ slightly).
- An EC declaration of conformity is available at www.schmitzsiegen.de.

Page 4

Page 1

machine 

sided bracket

IDxt**

min. BR = 'Minimum bend radius': Lowest 

permissible hose bend radius

1+2 wire=1&2SN/SC; 4-wire=4SP&4SH  

When using this securing series, do not secure 

any heavy hoses NOR lay them in a small 

bend radius! (Exceptions only permitted after 

all individual parameters have been tested and 

upon the express written consent of the safety 

catch manufacturer).

Ident. No.
S-bracket

max.

kg/m

min. BR  

4 wire

min. BR

1+2 wire

max. 

BD***

B) Sizes and dimensions of the different types:   

Compatible for all standard fittings of the corresponding diameter nominal 'DN' according to DIN 20066

Other technical data to be complied with 

regarding the hose line to be secured

E bracket for union nuts; S bracket for SAE flanges; P bracket for 

a free fastening point. See the illustration below & point F

Size

cable-

Ø

for hydraulic hose

(OD in mm)*

for hydraulic hose

(OD in mm)*

Ident. No.
E-bracket

machine 

sided bracket

IDxt**

for hydraulic hose

(OD in mm)*

cable-

Ø

Subject to change without notice -  the latest version of the operation manual is available on www.cablelock.de

E-bracket

S-bracket

P-bracket

Subject to change without notice -  the latest version of the operation manual is available on www.cablelock.de

cable-

Ø

The last characters of the ID no. are stamped 

on the CE label. E.g.: "E224"

machine 

sided bracket

IDxt**

Ident. No.
P-bracket

Translation of the original operating

Instructions

(without guarantee for correctness)       Version 2021

Translation of the original operating

Instructions

(without guarantee for correctness)       Version 2021

Component overview 
(example AS3-ECO):

(Example AS3 ECO)

X

FL

Z

Y

AS-ECO

AS-ECO

tensioner lock 'basic'

cable bow

fixing 
bracket

machine-sided fixation point

crimping

pressure hose

hose protection

'AS-Tape'

hose-sided 

cable sling

hose fitting

Bracket forms:

E-bracket

S-bracket

P-bracket

Attention: 

only use the shown 

fixation options if 

the tensioner locks 

are positioned in 

the inner region of 

the bending radius. 

Otherwise turn the 

tensioner locks 

around. 

Mounting method: 

free, sufficiently 

stable fastening point 

with screw (with 

installation lengths as 

described in the

above formula on this 

page)