Configuration
System messages tab
Status and error messages can be sent automatically to the SNMP manager or via e-mail to the selected addresses
immediately after they occur via the Ethernet interface or WLAN card. The messages to be sent and the destination
addresses can be selected on the "System messages" tab.
7
"System messages" tab on the printer website
Fig.
Column
Meaning
Description
Status and error messages that can be sent.
Expand tree structure by clicking the circular symbol once or double-clicking the description.
An entry for a higher-order description (e.g. note) is automatically accepted for all subordinate
descriptions (e.g. "Start", "Not ready", "Ribbon running out").
SNMP 1
SNMP 2
Management stations on local network which communicate with the printer via SNMP. To make
use of SNMP functionality, the SNMP agent must be activated (
page 24).
Select management station by clicking the corresponding cell.
The selection is indicated via a symbol. To undo the selection click it again.
Valid e-mail address for the SMTP server to which the message is to be sent.
Click cell and enter e-mail address or select from pull-down menu.
Sound
Audible signal which indicates receipt of the message.
Click cell and select signal type in pull-down menu.
13 Parameters on "System messages" tab
Table
To change a parameter:
Locate the parameter in the tree structure.
Select the management stations or enter the e-mail address.
Select the sound.
C
lick
Set
.
Enter PIN and click
OK
.
1.
2.
3.
4.
5.