40
40
6.16
Set Cylinder Peel Position / Actor 3.0
6.16.1 Set throttle valves on cylinder 'peel position'
3.03
Z
X
Y
3.05
Throttle valve (3.03) movement inside
with silencer
Close throttle valve (3.03) completely.
Turn the set screw clockwise until it stops.
If no different value is noted in the test report, open the throttle
valve (3.03) by turning it
3 turns
counterclockwise.
Throttle valve (3.05) movement inside
Marker on the tube with number 5
Close throttle valve (3.05) completely.
Turn the set screw clockwise until it stops.
If no different value is noted in the test report, open the throttle
valve (3.05) by turning it
7 turns
counterclockwise.
Fig. 46
Throttle valve on the cylinder 'peel position'
6.16.2 Set sensor on cylinder 'peel position'
12 mm
3.12
Sensor (3.01) pad assembly in basic position
Marker on the sensor with number 5
If no different value is noted in the test report,
set the distance between the edge of the sensor (3.01) and the
edge of the cylinder to 12 mm.
As a check, switch on the printer and switch on compressed air.
In the start position of the applicator, the LED on the sensor must
light up. In this position, the pad assembly is at a maximum distance
from the dispensing edge of the printer.
When the cylinder extends and the pad assembly moves to the
dispensing edge of the printer, the LED goes out.
Fig. 47
Sensor on the cylinder 'peel position'