39
6.15
Set Cylinder Pliers / Actor 3.1
6.15.1 Set throttle valves on cylinder 'pliers'
3.06
Z
X
Y
Throttle valve (3.06) movement outside
Marker on the tube with the number 6
Close throttle valve (3.06) completely.
Turn the set screw clockwise until it stops.
If no different value is noted in the test report, open the throttle
valve (3.06) by turning it
8.5 turns
counterclockwise.
Fig. 44
Throttle valves on cylinder 'pliers'
6.15.2 Set sensor on cylinder 'pliers'
17 mm
3.12
Sensor (3.12) pliers open
Marker on the sensor with the number 6
If no different value is noted in the test report, set the distance
between the edge of the sensor (3.12) and the edge of the compact
cylinder to 17 mm.
As a check, switch on the printer and switch on compressed air.
In the start position of the applicator, the LED on the sensor must
light up. The pliers are open in this position.
When the pliers are closed, the LED goes out.
Fig. 45
Sensor on cylinder 'pliers'