22
22
6.5
Adjusting the Product Sensor
The product sensor detects the labelling position of the pad in relation to the product.
The adjustment of the product sensor is dependant on the operation mode - blow on.
The detection distance of the sensor is 5 - 200 mm from the bottom edge of the sensor.
i
Note!
To apply the label correctly onto the product the distance be between pad and product may exceed 10 mm.
1
2
3
3
5
4
6
max. 10mm
A
B
Setting the product sensor
There are two LEDs on the product sensor to indicate the
operational status.
green LED (4) lit up - Sensor operational
yellow LED (5) glow - Sensor has switched
A small spot of red light shows the detection point of the
product.
!
Attention!
Before undertaking any adjustments
disconnect the compressed air supply.
1. Insert the male round connector (1) into the female round
connector (2) on the sensor (3) and tighten the nut.
2. Place a product under the pad.
3. Pull the tubes out of the throttle valves (7, 8) and move
the pad from position A to position B with a maximum of
10 mm distance to the product.
4. If the yellow LED (6) lights up in this position turn the
setting screw (5) counterclockwise until the yellow LED (6)
switches off.
5. Turn the setting screw (5) clockwise slowly so that the
yellow LED (6) lights up again.
6. After successful setting put in the tubes into the throttle
valves (7, 8) and switch on the pressurized air.
7. Quit the error message on the printer with the
pause
button. Pad will move to the start position.
7
8
Fig. 22
Product Sensor