21
Measuring point (MP S) of the Supporting Air
3
2
1
MP S
Fig. 20
Measuring points to measure the support air
Use a manometer with a measuring range of -7 to
7 bar to measure the pressure.
MP S: Supporting Air (reference value 2 Bar)
1. Dismount cover and connect the manometer to
the MP S.
- Tube (2) from valve block to blow tube
connector.
- Fitting (3) on the blow tube.
2. Activate the valve manually by pressing the
micro switch (1) to measure the pressure.
3. If needed adjust the pressure using the throttle
valve "support air".
4. Mount cover.
!
Attention!
After the pressure has been measured ensure that all connections are properly reestablished.
6.4
Adjusting the Sensor on Cylinder Z
3
2
1
10 mm
Fig. 21
Sensors on cylinder Z
Sensor Start Position 1
1. Loosen screw (1) of the sensor "Start Position" (3) and move the sensor to the top edge of the sensor holder.
2. Loosen screw (2) and move the sensor holder to a distance of 10 mm between top edge of the sensor and the
bottom edge of the connecting ring of cylinder, as illustrated.
3. Tighten screw (2)
4. Check the sensor during the applicator operation.
- When the cylinder is moved in and the pad is in start position the LED at the sensor lights up.
- The pad is not in the start position. - LED at the sensor does not light up.