6.6
Adjusting the Blow Tube (Supporting Air)
The blow tube must be adjusted in such a way that the label takeover is unhindered by turbulence and the supporting
air blows the label evenly against the pad.
The default factory value is 2 bar.
i
Note!
When changing the label size (2", 4" or 6") the appropriate blow tube is to be used.
3
5
1
2
5
3
4
Fig. 24
Adjust the blow tube
The blow tube (4) for the supporting air can be rotated around its axis. That way the direction of the supporting air can
be optimized.
1. Loosen screw (1).
2. Put the blow tube (3) into the tube adapter B (2).
Turn the blow tube (2) in the direction that the air current can support the take up of the label.
•
For small labels direct the air current more toward the dispensing edge (5) of the printer.
•
For larger labels direct the air current away from the dispense edge (6).
Use the graduation guide for orientation.
3. Open as many holes of the blow tube as are needed to cover the label width. Remove rings (4) if necessary.
All holes outside the label width should be covered with the shrink tube rings provided. Once the unneeded holes
have been covered the shrink tube should be shrunk.
4. Tighten screw (1).
Summary of Contents for 4214 Series
Page 1: ...Service Manual 4214 MADE IN GERMANY Stroke Turn Applicator...
Page 39: ...39 9 Drawings 9 2 Pneumatic Drawing Type 4214 Fig 43 Pneumatics type 4214...
Page 40: ...40 40 9 Drawings 9 3 Labeling Position Type 4214 L Fig 44 Labeling position 4214L...
Page 41: ...41 9 Drawings 9 4 Label Position Type 4214 R Fig 45 Labeling position 4214R...