background image

13

Licences

5.1 

Declaration of Incorporation

cab Produkttechnik  
GmbH & Co KG 
Wilhelm-Schickard-Str. 14 
D-76131 Karlsruhe 
Germany

Declaration of Incorporation

We declare herewith that the following „partly completed machinery“ as a result of design, construction and the version 
put in circulation complies with the essential requirements of the 

Directive 2006/42/EC on machinery

:

Annex I, Article 1.1.2, 1.1.3, 1.1.5, 1.1.6, 1.2.1, 1.3.2, 1.5.2, 1.5.8, 1.6.3, 1.7

In the event of any alteration which has not been approved by us being made to any device as designated below, this 
statement shall thereby be made invalid.

Device:

Stroke Applicator

Type:

4126C, 4136C

Applied EU Regulations:

Applied Standards:

Directive 2006/42/EC on machinery:

• 

EN ISO 12100:2010

• 

EN ISO 13849-1:2008

• 

EN 60950-1:2006 
+A11:2009+A12:2011+A1:2010+A2:2013

Other Relevant Directives:

• 

Directive 2014/30/EU relating to electromagnetic compatibility

• 

Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and 
electronic equipment

Person authorised to compile the technical file:

Erwin Fascher 
Am Unterwege 18/20 
99610 Sömmerda

Signed for, and on behalf of the Manufacturer:

cab Produkttechnik Sömmerda 
Gesellschaft für Computer- 
und Automationsbausteine mbH 
99610 Sömmerda

Sömmerda, 08.07.2019

Erwin Fascher 
Managing Director

The product must not be put into service until the final machinery into which it is to be incorporated has been declared in 

conformity with the provisions of the Directive on machinery.

The documents according annex VII part B from the incomplete machinery are created and will commit to state agencies 
on request in electronic kinds.

Summary of Contents for 4126C

Page 1: ...Made in Germany Assembly Instruction 4126C 4136C Stroke Applicator ...

Page 2: ...r Please check www cab de for the latest update Terms and conditions Deliveries and performances are effected under the General conditions of sale of cab Assembly instructions for the following products Germany cab Produkttechnik GmbH Co KG Karlsruhe Phone 49 721 6626 0 www cab de USA cab Technology Inc Chelmsford MA Phone 1 978 250 8321 www cab de us Taiwan cab Technology Co Ltd Taipei Phone 886 ...

Page 3: ...scription 6 2 1 Important Features 6 2 2 Technical Data 6 2 3 Function 7 2 4 Overview 8 2 5 Contents of Delivery 9 3 Operation 10 3 1 Standard Operation 10 3 2 Cleaning 10 4 Error Messages 12 4 1 Error Messages of the Printer 12 4 2 Error Messages of the Applicator 12 5 Licences 13 5 1 Declaration of Incorporation 13 5 2 EU Declaration of Conformity 14 ...

Page 4: ...and the recognized safety rules However danger to life and limb of the user or third parties and or damage to the device and other tangible assets can arise during use The device may only be used for its intended purpose and if it is in perfect working order and it must be used with regard to safety and dangers as stated in the operating manual The device applicator mounted on a cab printer of the...

Page 5: ...ervice technicians Unauthorized interference with electronic modules or their software can cause malfunctions Other unauthorized work on or modifications to the device can also endanger operational safety Always have service work done in a qualified workshop where the personnel have the technical knowledge and tools required to do the necessary work There are various warning stickers on the device...

Page 6: ...from the side from the top from below from the side Compressed air pressure bar 4 5 4 5 4 5 4 5 Blow tube number 1 1 2 2 Cycle time about frequency aprox labels min 1 20 20 20 20 Tamp pad 4126C 11 F 4126C 12 F 4126C 19 F Label width mm 46 174 Label height mm 20 100 Product distance to lower edge up to mm 220 320 Immersion depth pad F2 mm 90 Product during labeling fixed Tamp pad spring loaded 4126...

Page 7: ...inder retracted mini lift cylinder extended main lift cylinder retracted mini lift cylinder retracted intermediate stop main lift cylinder retracted mini lift cylinder retracted main lift cylinder retracted mini lift cylinder extended labeling position main lift cylinder extended mini lift cylinder retracted main lift cylinder extended mini lift cylinder extended Fig 2 Function of the applicators ...

Page 8: ...mpressed air connector 3 Shutoff valve 4 mini lift cylinder with lift pad support 5 Blow tube for supporting air 6 Upper holes for attaching on the printer 7 SUB D 15 Interface to the printer 8 Lower holes for attaching on the printer y x z 2 Product Description Front View y x z ...

Page 9: ...ad 4 Pad as ordered 5 Documentation Fig 4 Contents of delivery i Note Please keep the original packaging in case the applicator needs to be returned Attention The device and printing materials will be damaged by moisture and wetness X Only set up the label printer with applicator in dry locations protected from moisture and splashes ...

Page 10: ...d is initiated The processed labels have to be removed manually After a few seconds the printer carries out a short backward feed to position the front edge of the next label at the printing line i Note The synchronization also has to be carried out when the print job has been interrupted with the cancel key Synchronizing is not necessary when the print head was not lifted between print jobs This ...

Page 11: ...ther alignment elements This will enable use of the applicator directly after cleaning Turning away dismounting the applicator 1 To turn away the applicator loosen thumbscrew 5 and swing the applicator to the side 2 Disconnect SUB D 15 male connector 6 from the female connector 7 of the printer 3 Loosen screw 4 and move the locking plate 3 from the hinges 4 Lift the applicator upward and off the p...

Page 12: ...of the switch state at the upper sensor at the cylinder between the start of the labelling process and the signal from the labelling position sensor Upper position Pad is not in the starting position when the printer is switched on Pad has not reached the labelling position within 2s after the movement of the pad was started Pad has left the printing position without authorization Vac plate empty ...

Page 13: ...EN ISO 12100 2010 EN ISO 13849 1 2008 EN 60950 1 2006 A11 2009 A12 2011 A1 2010 A2 2013 Other Relevant Directives Directive 2014 30 EU relating to electromagnetic compatibility Directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment Person authorised to compile the technical file Erwin Fascher Am Unterwege 18 20 99610 Sömmerda Signe...

Page 14: ...ade invalid Device Stroke Applicator Type 4126C 4136C Applied EU Regulations Applied Standards Directive 2014 30 EU relating to electromagnetic compatibility EN 55022 2010 EN 55024 2010 EN 61000 6 2 2005 Directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment EN 50581 2012 Commission delegated directive EU 2015 863 amending Annex II...

Reviews: