WARNING

GENERAL INFORMATIONS

The product shall not be used for purposes or in ways other than those for which the product is intended for and as described in this manual. 
Incorrect uses can damage the product and cause injuries and damages.
The company shall not be deemed responsible for the non-compliance with a good manufacture technique of gates as well as for any de-
formation, which might occur during use. Keep this manual for further use. 

INSTALLER GUIDE

This manual has been especially written to be use by qualified fitters. Installation must be carried out by qualified personnel (professional 
installer, according to EN 12635), in compliance with Good Practice and current code. 
Make sure that the structure of the gate is suitable for automation. 
The installer must supply all information on the automatic, manual and emergency operation of the automatic system and supply the end 
user with instructions for use.

GENERAL WARNINGS

Packaging must be kept out of reach of children, as it can be hazardous. 
For disposal, packaging must be divided the various types of waste (e.g. carton board, polystyrene) in compliance with regulations in force. 
Do not allow children to play with the fixed control devices of the product. 
Keep the remote controls out of reach of children. 
This product is not to be used by persons (including children) with reduced physical, sensory or mental capacity, or who are unfamiliar with 
such equipment, unless under the supervision of or following training by persons responsible for their safety. 
Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazard. 
Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of 
the system and forces generated by the automated system. 
Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453. 
Only use original accessories and spare parts, use of non-original spare parts will cause the warranty planned to cover the products to 
become null and void. 
All the mechanical and electrical parts composing automation must meet the requirements of the standards in force and outlined by CE marking.

ELECTRICAL SAFETY

An omnipolar switch/section switch with remote contact opening equal to, or higher than 3mm must be provided on the power supply mains.
Make sure that before wiring an adequate differential switch and an overcurrent protection is provided.
Pursuant to safety regulations in force, some types of installation require that the gate connection be earthed. 
During installation, maintenance and repair, cut off power supply before accessing to live parts. 
Also disconnect buffer batteries, if any are connected. 
The electrical installation and the operating logic must comply with the regulations in force. 
The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation of at least 1 mm. 
The leads must be secured with an additional fixture near the terminals.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electrical parts
Check all the connections again before switching on the power. 
The unused N.C. inputs must be bridged.

WASTE DISPOSAL

As indicated by the symbol shown, it is forbidden to dispose this product as normal urban waste as some parts might be harmful for envi-
ronment and human health, if they are disposed of incorrectly. 
Therefore, the device should be disposed in special collection platforms or given back to the reseller if a new and similar device is purchased. 
An incorrect disposal of the device  will result in fines applied to the user, as provided for by regulations in force.

Descriptions and figures in this manual are not binding. While leaving the essential characteristics of the product unchanged, the manufacturer reserves 
the right to modify the same under the technical, design or commercial point of view without necessarily update this manual.

TECHNICAL DATA

Contol unit supply

24 Vdc

Power supply

100÷250 Vac 50/60 Hz

Output supply

1/2 motor 24Vdc

Maximum motor current

7+7 A 

Output supply accessories

24Vdc 500mA max.

Protection level

IP55

Operating temp.

-20°C / +50°C

Radio receiver

built in 433,92 MHz confgurabile

Rolling code transmitters supported

64

Summary of Contents for 1-10010

Page 1: ...L8543262 02 2020 rev 1 HYBRA 24 IT EN DE FR ES PL ...

Page 2: ...115V 100 250 Vac POWER INPUT SELECTION GND GND M1 M2 LAMP 24Vdc Lock 12Vdc 10W 5s 24Vdc 500mA max COM PHOTC ENC 1 ENC 2 BAR PHOTO STOP CLOSE PED P P AUX1 OPEN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 JMP1 JMP1 DAS Open DAS N C JMP1 BAR Close DAS 8K2 8k2 BAR 26 27 28 29 30 31 32 33 36 37 34 35 24V M4 1 ...

Page 3: ...4 5 6 26 27 28 29 30 31 HYBRA24 M1 M2 ENC1 ENC2 K R B G W K R B G W M1 M2 K R B G W ENC ENC ENC M 24 M 24 Bianco White Weiß Blanc Blanco Biały Verde Green Grün Vert Verde Zielony Marrone Brown Braun Brun Marrón Brązowy Rosso Red Rot Rouge Rojo Czerwony Nero Black Schwarz Noir Negro Czarny AUX1 SCA AUX1 0 AUX2 SCA AUX2 0 24Vdc 500mA max SCA 24Vdc 3W max 11 12 34 35 36 37 24Vdc 500mA max 9 10 11 12 ...

Page 4: ... L N Service Zone Light 230Vac Relè 24Vdc 24Vdc 500mA max 11 12 AUX1 2 24Vdc 500mA max 9 10 11 12 Service Zone Light 230Vac L N Relè 24Vdc 34 35 36 37 24Vdc 24Vdc COM NC NO RX1 TX1 24Vdc 24Vdc COM NC NO RX2 TX2 11 24Vdc COM PHOT COM PHOT C 24Vdc 12 11 12 13 18 13 19 9 10 9 10 test1 on test2 ON AUx1 4 AUx1 4 AUX1 AUX1 4 5 ...

Page 5: ...tst1 tst2 tstm rem PRG spd2 99 PRG PRG PRG sld2 pmo1 sld1 30 20 30 PRG PRG PRG PRG PRG PRG PRG PRG pmc1 pmo2 pmc2 pso1 pso2 psc2 tdmo 20 20 20 20 psc1 20 20 2 20 PRG PRG PRG PRG PRG tdmc tloc seav sear tinc aux1 aux2 2 tls 5 0 0 60 PRG 250 PRG 0 PRG 1 Schema menu di programmazione Menu programming layout Diagramm Programmiermenü Menu de programmation Menú de la carta de programación Układ menu pro...

Page 6: ...cisnąć przycisk PG Premere simultaneamente e Press simultaneously keys and Gleichzeitig und drücken Presser simultanément et Presionar simultáneamente y Naciskać jednocześnie i Selezionare il valore desiderato con i pulsanti e Increase decrease the value with keys and Mit den Tasten und kann man eingerichtete Werte ändern Régler la valeur désirée avec les touches et Establecer con las teclas y el ...

Page 7: ...roducts to become null and void All the mechanical and electrical parts composing automation must meet the requirements of the standards in force and outlined by CE marking ELECTRICAL SAFETY An omnipolar switch section switch with remote contact opening equal to or higher than 3mm must be provided on the power supply mains Make sure that before wiring an adequate differential switch and an overcur...

Page 8: ...t for connection of back up batteries accessory HYBRA 24 Terminal No Function Description 1 2 Motor 1 Connection motor 1 24VDC 16A max 3 4 Motor 2 Connection motor 2 24VDC 16A max 5 6 Flashing light Connection flashing light 24VDC 15W max 7 8 Lock Output 12Vdc 10W power supply for electric lock 7 0V 8 12V 9 10 AUX1 N O contact free from voltage can be configured via the AUX1 parameter as Open gate...

Page 9: ...he central unit performs a sequence of operations single partial openings full openings and closings at different speeds and so on D u r i n g this phase the display will show some acronyms that indicate the operation that is being performed at that time OPM1 2 motor 1 or 2 in opening phase CLM1 2 motor 1 or 2 in closing phase If the motor movement is opposite to what is indicated on the display s...

Page 10: ...n is adjusted in the closing phase at normal speed Motor 1 1 99 50 PMo2 The anti crash device amperometric sensor operation is adjusted in the opening phase at normal speed Motor 2 1 99 50 PMc2 The anti crash device amperometric sensor operation is adjusted in the closing phase at normal speed Motor 2 1 99 50 Pso1 The anti crash device amperometric sensor operation is adjusted in the opening phase...

Page 11: ...tomatic closing disabled ON IbL Enables or disables condominium function On condominium function enabled The step by step impulse or transmitter impulse has no effect during the opening phase Off condominium function disabled OFF ibca The multi flat function is enabled or disabled during the TCA counting On the bloc of flat function is enabled The Step by Step signal or the transmitter signal has ...

Page 12: ... On Check enabled If the check has a negative result no manoeuvre is commanded Off Check disabled OFF rem Enables or disables remote radiotransmitters learning as indicated in the paragraph Remote transmitters learning On Remote learning enabled Off Remote learning not enabled OFF CAUTION Any change to one of these parameters logic SPD1 SPD2 SLD1 SLD2 TSM1 TSM2 SOFT involves a complete operation a...

Page 13: ...ter can be changed with keys and press OK to confirm the flashing character then confirm the following one after typing in the 4 characters a confirmation message CONF appears after a few seconds the code 0000 appears again the previously stored protection code must be reconfirmed in order to avoid any accidental typing in If the code corresponds to the previous one a confirmation message OK appea...

Page 14: ...error Check motor 1 connections Err2 Motor 2 circuit checking error Check motor 2 connections Err3 error fault power circuit Request technical assistance and eventually replace control unit Err4 PHOTA photocell checking error Check connections PHOT A photocell alignment or presence of obstacles Err5 PHOTC photocell checking error Check connections PHOTC photocell alignment or presence of obstacles...

Page 15: ...n 3 Zuletzt die beiden als Scharnier dienenden Schrauben lockern aber nicht ausbauen damit der Deckel geöffnet werden kann 1 Presser les deux ailettes latérales pour décrocher les deux cache vis 2 Enlever les deux vis sur le côté d ouverture désiré 3 Desserrer les deux vis faisant fonction de charnière sans les enlever de manière à permettre l ouverture du convercle 1 Presionar las aletas en los l...

Page 16: ...AUTOMATISMI CAB Srl Via della Tecnica 10 z i 36010 Velo d Astico VI Italia Tel 0445 741215 Fax 0445 742094 info automatismicab com www automatismicab com ...

Reviews: