Page 1: ...INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS ESTAMPINOX EFN PUMP c Telers 54 Aptdo 174 E 17820 Banyoles Girona Spain 01 021 30 04EN ED 2009 02...

Page 2: ...73 23 EEC Directive and are conforms with UNE EN 60204 1 1997 and UNE EN 60034 1 A11 2002 EMC Directive 2004 108 EC what repeal 89 336 EEC Directive and are conforms with UNE EN 60034 1 A11 2002 In c...

Page 3: ...ng parts of the equipment Danger Electricity Danger Caustic or corrosive agents Danger Suspended loads Danger to the proper operating of the machine Obligation to ensure safety at work Use of safety g...

Page 4: ...nt Failure to comply with specific maintenance and repair procedures Potential electrical mechanical and chemical hazards Atmospheric conditions in the room could be hazardous due to the release of ch...

Page 5: ...N 8 5 Start up 5 1 START UP 9 6 Operating problems 7 Maintenance 7 1 GENERAL MAINTENANCE 11 7 2 STORAGE 11 7 3 CLEANING 11 7 4 PUMP DISASSEMBLY 12 7 5 PUMP ASSEMBLY 13 8 Technical Specifications 8 1 T...

Page 6: ...or this pumps are pump with trolley control panel with stop start contactor and emergency stop push button EFH Motor IEC IP 55 protection Class F insulation Three phased power supply with 220 240 380...

Page 7: ...ied with a motor from INOXPA Unpack the pump and check the following The pump suction and delivery connections removing the remains of any packing material Check that the pump and the motor have not s...

Page 8: ...r with respect to the tank in order for the static suction head be at its maximum Place brackets for the piping as near as possible to the suction and delivery mouths of the pump 4 5 SHUT OFF VALVES T...

Page 9: ...ped The pump must NEVER rotate without liquid Check that the rotation direction of the motor is correct 5 1 2 Checks to be carried out on putting the pump into operation Check to make sure that the pu...

Page 10: ...he suction pressure See Number 2 also 5 The pump is sucking air Check the suction piping and all of its connections 6 Obstructed suction piping Check the suction piping 7 Delivery pressure is too high...

Page 11: ...e exposure of the parts to excessively damp atmospheres 7 3 CLEANING The use of aggressive cleaning products such as caustic soda and nitric acid may give rise to skin burns Use rubber gloves during t...

Page 12: ...rt gas d Materials EPDM PTFE recommended FPM NBR not recommended 7 4 PUMP DISASSEMBLY n Remove the screws 51 nuts 54 washers 53A and take out the housing 01 o Loosen the hexagonal screw 52A of the pum...

Page 13: ...BLY n Mount the lantern 04 and fix it to the motor 93 with the Allen keys 51B and washers 53A 53B o Mount the flange 04A to the allen screws 51A fixing it to the lantern p Slide the shaft 05 over the...

Page 14: ...55B EFH 2375 2375A 35 r Slide the impeller 02 over the shaft into its recess Fix it on with the washer 53 and screw 52A while holding the impeller 02 so that it does not turn For sizes EFH 2340 up to...

Page 15: ...tor 47A to the screws 50A with a screw driver IMPORTANT When assembling the new seal be careful and mount the parts and the O rings with soapy water in order to allow an easy glide of the parts either...

Page 16: ...ts in stainless steel AISI 304 Gaskets and joints in contact with the product EPDM and Silicone standard Other optional joints materials Consult your supplier Surface finish Finish Ra 0 8 Mechanical s...

Page 17: ...25 150 100 10 46 140 170 EFH 2340 EFH 2340B 112 4 2 2 70 510 92 192 112 276 140 168 125 12 57 190 222 EFH 2355 EFH 2355A 112 5 5 535 EFH 2375 EFH 2375A 132 7 5 610 132 329 178 212 150 75 216 262 8 4 E...

Page 18: ...167 36 106 15 88 55 149 2 114 3 4 168 11 B 143 145TC 22 23 56 EFN 2107 A 56C 1 1 159 50 105 15 88 55 B 143 145TC 22 23 56 EFN 2222 B 143 145TC 1 1 54 166 66 122 EFN 2222A C 182 184TC 185 28 58 75 184...

Page 19: ...ED 2009 02 8 Technical Specifications 19 8 6 ESTAMPINOX EFH...

Page 20: ...20 8 Technical Specifications ED 2009 02 8 7 ESTAMPINOX EFN...

Page 21: ...ED 2009 02 8 Technical Specifications 21 8 8 ESTAMPINOX EFH PUMP SECTION...

Page 22: ...1 AISI 316L 08 Mechanical seal 1 1 1 1 1 1 Ceram Graf NBR 23 Counter flange 1 GG 15 30 Lantern ferrule 1 GG 15 35 Impeller washer 1 1 1 A4 47A Protector 1 1 1 1 1 1 Plastic 50A Screw 2 2 2 2 2 2 A2 51...

Page 23: ...ED 2009 02 8 Technical Specifications 23 8 10 ESTAMPINOX EFN PUMP SECTION...

Page 24: ...antern flange 1 1 1 1 GG 15 05 Shaft 1 1 1 1 1 AISI 316L 08 Mechanical seal 1 1 1 1 1 Ceram Graf NBR 30 Lantern ferrule 1 GG 15 35 Impeller washer 1 1 A4 47A Protector 1 1 1 1 1 Plastic 50A Screw 2 2...