C-Dax MULTI BOOM 1018 Instruction Leaflet Download Page 5

 

CALIBRATION 

 

4.5M Effective Width 

 

To calibrate the Multiboom, the outer nozzles must be adjusted so that their effective 
spray width is 1.5M each.  This makes the effective width of the boom 4.5M. 

 

Because the outer nozzles are covering an area three times as wide as each nozzle in the 
center section, they must be selected to produce three times the flow of each center 
nozzle at the same pressure.   

 

Centre Tips (3 required) 

 

Outer Tips (2 required) 

 

Boom Flow @ 2bar 

 

 

 

 

 

 

 

 

 

 

L/Min 

 

 

 

Yellow  02 (Pt No. 5300-9800) 

OC06  (Pt No.

 

5300-3700)  

5.83   

 
 

 

Operating Shut-off Valves 

 
Locate the red shut-off knob on the side of each nozzle body.  Rotate the knob clockwise 
to shut the flow off to the tip, anti-clockwise to allow fluid through the tip.  The knob may 
need to be pushed in towards the nozzle body in order to relocate on the thread. 
 

DETERMINING APPLICATION RATE 

 

Once the tip size and effective spray width have been set, measure the flow from the tips 
using a measuring jug.  Calculate the boom flow rate as follows; (all flows in Litres/Minute) 

 

Boom Flow= (Centre tip flow x 3) + (Outer tip flow x 2) 

 

Calculate the application rate as follows; 
 

L/Ha=  

 

Boom Flow(L/Min) x 600   

 

Effective Spray Width (Metres) x Speed (KPH) 

 
 
 

SPARE PARTS 

 

Part 

Number  Description 

  Quantity 

Required 

1600-6000 

 Nozzle 

Cap 

   5 

3400-5400 

 Nozzle 

Filter 

   5 

4100-0010   

8.5mm Delivery Hose 

 

By the metre as needed 

5300-1900 

 Nozzle 

Body 

Inner 

  3 

5300-1600 

 Nozzle 

Body 

Outer 

  2 

5300-2600   

Swivel Body Outer   

 

5300-3700  

OC-06 

Brass 

Nozzle 

Tips 

 

5300-9800  

110WR02 

Nozzle 

Tips   

 
 
 

Summary of Contents for MULTI BOOM 1018

Page 1: ...pment be aware concerned prudent and properly trained in safety This also applies to equipment that is loaned or rented to someone who has not read the owner s manual and is not familiar with the oper...

Page 2: ...d or implied by law in respect of the equipment or advice relating to the equipment provided to you by C Dax are excluded to the extent permitted by law 1 6 Notwithstanding anything else in this manua...

Page 3: ...re C Dax elects to repair or replace the equipment it will use reasonable endeavours to do so as soon as practicable but will not be liable for any delay in doing so 1 9 You agree that the transaction...

Page 4: ...wivel fittings that allow the effective spray width to be adjusted Optional parts are as follows 4500 1050 Standard Mounting Brackets 1074 Where an existing Quicksmart Frame is mounted 1073 Quicksmart...

Page 5: ...flow off to the tip anti clockwise to allow fluid through the tip The knob may need to be pushed in towards the nozzle body in order to relocate on the thread DETERMINING APPLICATION RATE Once the tip...

Page 6: ...6 PARTS DIAGRAM...

Page 7: ...stic 12 1 4100 0010 Hose Spray Delivery 40 Bar 10mm ID Yellow 2 5m 13 1 4500 2200 Kit Dry Break 8 5x10 Quick Coupler Brass 14 2 5300 1600 Nozzle Body DCV 3 8BSPMx22x10 Incl O Ring Less Cap 15 3 5300 1...

Page 8: ...22x10 Incl O Ring Less Cap 2 1 3280 0634 Fastener Self Tap Screw Pan 6Gx3 4 Pozi ZP 3 1 3400 5400 Filter Nozzle Tip 50 Mesh Plastic 4 1 5300 XXXX Nozzle Tip SPECIFY TYPE WHEN ORDERING 5 1 1600 6000 Ca...

Page 9: ...Less Cap 2 1 5300 2600 Nozzle Body Swivel Single 3 8BSPFxQC Nylon 3 1 3400 5400 Filter Nozzle Tip 50 Mesh Plastic 4 1 1600 6000 Cap Nozzle Fan QC Red Incl Gasket 5 1 5300 XXXX Nozzle Tip SPECIFY TYPE...