background image

BZBGEAR BG-VPTZ-HSU3

PRODUCT MANUAL

Operation Controls and Functions

Connections Overview

No.

Name

1

IR Lens

2

IR Receiver

3

Power Indicator

4

DC12V Input

5

COM Port (RS485/RS232)

6

LAN (PoE)

7

3G-SDI Output

8

HDMI Output

9

USB 3.0 Type-B

10

3.5mm Audio-Input

Address:

830 National Drive #140, Sacramento, CA 95834, USA

·

Tel:

+1(888)499-9906

·

Email:

[email protected]

8

Summary of Contents for BG-VPTZ-10HSU3

Page 1: ...BG VPTZ HSU3 PTZ Full HD 1080P 10X 20X 30X Zoom HDMI SDI USB3 0 IP Live Streaming Camera with POE User Manual...

Page 2: ...BZBGEAR BG VPTZ HSU3 PRODUCT MANUAL Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 499 9906 Email support bzbgear com 2...

Page 3: ...nd Functions 8 Remote Control 11 Operation Instructions 12 Menu Settings 14 Network Connection 18 Camera Web Interface 22 Application Example 30 Installation Instructions 31 Tech Support 32 Warranty 3...

Page 4: ...e case Installation and maintenance should only be carried out by qualified technicians Do not use the product beyond the specified temperature humidity or power supply specifications This product doe...

Page 5: ...izontal field of view Equipped with advanced image processing technology and a full HD 1 2 8 CMOS Sensor 1 2 7 sensor on 10x 10 20 30X Optical Zoom and a maximum resolution of 1080P 60fps Low Video No...

Page 6: ...Packing List 1x BG VPTZ HSU3 Camera 1x IR Remote Controller 1x RS 232 to DB 9 pin cable 1x 12V 2 0 A DC Power Adapter 1x User Manual Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 4...

Page 7: ...e Parameters Video Output Interface HDMI 3G SDI IP Streaming USB 3 0 Video Network Coding H 265 H 264 MJPEG Communication IX RS232 IN IX RS232 Out IX RJ45 RS485 Control Protocol VISCA PELCO D PELCO P...

Page 8: ...ns Overview No Name 1 IR Lens 2 IR Receiver 3 Power Indicator 4 DC12V Input 5 COM Port RS485 RS232 6 LAN PoE 7 3G SDI Output 8 HDMI Output 9 USB 3 0 Type B 10 3 5mm Audio Input Address 830 National Dr...

Page 9: ...ick controllers RS232 INPUT NO Function Definition 1 DTR Data Terminal Ready 2 DSR Data Set Ready 3 TXD Transmit Data 4 GND Ground 5 RXD Receive Data 6 GND Ground 7 IR OUT IR Signal Output 8 NC No Con...

Page 10: ...BZBGEAR BG VPTZ HSU3 PRODUCT MANUAL Camera Dimensions Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 499 9906 Email support bzbgear com 10...

Page 11: ...position 8 Preset Erase Key Press Reset Number 1 9 to erase the corresponding Preset 9 Preset Setting Key Press Preset Number 1 9 to save the corresponding preset 10 Focus Key AUTO Automatic focus MA...

Page 12: ...Pressing and holding the button will rotate it faster Menu Display Click the MENU button to display the on screen menu To exit press MENU again Focus AUTO Enable auto focus MANUAL Switch to manual foc...

Page 13: ...up to 9 presets To call a preset press the saved preset number no 1 9 To reset a preset press RESET then press the preset number no 1 9 you want to reset Image Flip P T Reset Click the FLIP button to...

Page 14: ...EXPOSURE and then press right to enter the sub menu AE MODE AUTO SHUTTER IRIS BRIGHT MANUAL Press right button to select options as defined below AE LEVEL Changes depending on selected AE MODE Not ava...

Page 15: ...ON 60 200 COLOR HUE 0 14 RED GAIN 0 255 MANUAL mode only BLUE GAIN 0 255 MANUAL mode only Picture Press the MENU button to display the OSD menu press the arrow keys to highlight PICTURE and then press...

Page 16: ...splay the OSD menu press the arrow keys to highlight NOISE REDUCTION then press right to enter the submenu 2D NR 0 5 OFF 3D NR 0 5 OFF DYN HOT PIXEL ON OFF Video Format Press the MENU button to displa...

Page 17: ...as the right picture shown LANGUAGE ENGLISH CHINESE ZOOM LABEL ON OFF PROTOCOL VISCA PELCO D PELCO P ADDRESS 1 255 AUTO BAUDRATE 2400 4800 9600 19200 38400 Restore Default Press the MENU button to dis...

Page 18: ...have the following default IP address 192 168 1 162 The computer must be on the same subnet as the camera to connect successfully therefore the computer must be connected to the 192 168 1 x subnet If...

Page 19: ...IP address In the IP address field enter a non conflicting IP address on the same subnet as the camera If there is another device with the same IP address you will not be able to connect In the exampl...

Page 20: ...dmin At the top left of your screen select Config On the left side of your screen select Network In the IP address field you will enter the unused IP address you selected at the beginning Our example...

Page 21: ...in IP address automatically and Obtain DNS server address automatically Click OK to close all network related screens Your computer and camera should now be on your network Open your web browser and e...

Page 22: ...oom buttons to adjust the zoom level of the camera Focus In Out Use the Focus buttons to manually adjust the camera s focus Speed Control Use the slider to adjust the PTZ speed of the camera Preset Ta...

Page 23: ...amera information including model number serial number firmware and hardware versions and MAC address Time Tab The time tab allows you to adjust time date and time zone settings Maintain Tab This tab...

Page 24: ...r Manual DNS settings Service Tab MSG Port default 8080 RTSP Port default 554 HTTP Port default 80 VISCA Port default 52381 WebSocket Port default 8880 Note Changing the port number requires restartin...

Page 25: ...29yx Port Set according to your streaming platform YouTube 1935 Facebook 443 Stream Type Select desired stream ONVIF Configuration Tab ONVIF Authentication Authentication enable default disable ONVIF...

Page 26: ...de is enabled GOP Frame interval 1 60 Default is 30 Bitrate Video Bit Rate 1 10240 Default is 4096 Resolution Set streaming video resolution Stream Mix Type Select Complex or Video Stream Complex Stre...

Page 27: ...Hue Hue adjustment slider Saturation Color saturations adjustment slider Sharpness Video sharpness adjustment slider Mirror Horizontal image reverse Flip Vertical image reverse Flicker Lighting flicke...

Page 28: ...g closer than the set value Sensitivity Auto focus sensitivity level ICR Mode Infrared Cut Filter Removal Mode AE Mode Auto Exposure Mode AE Level Auto Exposure Level adjustment HLC Highlight Compensa...

Page 29: ...PTZ Address Set the PTZ control address of the camera Protocol Set the serial control protocol Baud Rate Set the serial control baud rate LR Direction Reverse the left and right controls Vertical Axi...

Page 30: ...PRODUCT MANUAL Status Page On this screen you can view the current bit rates of the 3 IP streams Application Example Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 499 9906 Email su...

Page 31: ...BZBGEAR BG VPTZ HSU3 PRODUCT MANUAL Installation Instructions Address 830 National Drive 140 Sacramento CA 95834 USA Tel 1 888 499 9906 Email support bzbgear com 31...

Page 32: ...se visit bzbgear com warranty For questions please call 1 888 499 9906 or email support bzbgear com Mission Statement BZBGEAR is a breakthrough manufacturer of high quality innovative audiovisual equi...

Reviews: