6. RS232 Control
Connect the RS232 port to control device (e.g. PC) with RS232 cable. The splitter can
be controlled by sending RS232 commands.
RS232 Commands
The command lists are used to control the splitter. The RS232 control software (e.g.
docklight) needs to be installed on the control PC to send RS232 commands.
After installing the RS232 control software, please set the parameters of COM number,
bound rate, data bit, stop bit and the parity bit correctly, and then you are able to send
command in command sending area.
Baud rate: 9600
Data bit: 8
Stop bit: 1
Parity bit: none
Note:
All commands need to be ended with “<CR><LF>”.
In the commands, “[”and “]” are symbols for easy reading and do not need to be
typed in actual operation.
Type the command carefully, it is case-sensitive.
6.1
System Commands
Command
Description
Command Example and
Feedback
>GetFirewareVersion
Get firmware version.
<V1.0.0
>SetFactoryReset
Reset to factory default.
<FactoryReset_True
>SetReboot
System reboot.
<Reboot_EN
>SetHelp [Param]
Get the command details.
[Param]= Any command.
>SetHelp
SetHdcpActiveMode
<Set the HDCP bypass from
SRC or SINK
>SetHdcpActiveMode
Param
Param = Src,Sink
Src - Active by src
Sink - Active by Sink